• Title/Summary/Keyword: capacitive electrode

Search Result 168, Processing Time 0.021 seconds

AC Impedance Study of Oxygen Electrode in Phosphoric Acid Fuel Cell (교류 임피던스법에 의한 인산형 연료전지의 산소전극 특성 연구)

  • Song Rak-Hyun;Kim Chang-Soo;Shin Dong-Ryul
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.191-195
    • /
    • 2000
  • Electrochemical properties of the oxygen electrode in phosphoric acid fuel cell have been studied using AC impedance method as a function of applied potential, operating temperature and teflon content in the electrode. The oxygen electrode reaction in the $105wt.\%$ phosphoric acid is characterized by a parallel resistive component, $R_p$ and a capacitive component, $C_p$ with serial electrolyte resistance, $R_s$. The conductivity of the phosphoric acid is found to be 0.31-0.47 S/cm in the range of $130\;to\;190^{\circ}C$ from the measured impedance. The increase of applied potential and temperature produced the decreased RP and the increased $C_p$, which means the increase of the oxygen electrode reaction rate. The single cells with the cathode of various teflon contents were tested, and the cathode with $40wt.\%$ teflon showed good performance, which is considered to be related to an optimized impedance behavior.

COMPUTATIONAL STUDY FOR PERFORMANCE EVALUATION OF FLOW CHANNELS INSIDE CDI UNIT CELL (수치모사를 이용한 CDI Unit Cell 내부의 유로성능 평가)

  • Sohn, D.Y.;Choi, Y.H.;Park, D.W.;Jung, C.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • In the present study, computations for flow fields inside the CDI unit cells with electrodes and spacers have been made to evaluate their performance. Three types of unit cells that include a planar type, a serpentine channel type, and a spiral wound type were considered and their flow characteristics were compared. From the computational results, it is found that the serpentine channel type has a large flow resistance and can not guarantee the outflow flux for industrial applications. On the other hand, the planar type can sustain a large enough outflow flux but it's efficiency is low for the electrode-use because of the non-uniform velocity distribution inside the cell and dead zones in every corner. Finally, The spiral wound type has not only a large outflow flux as much as the planar type has, but also a high efficiency for the electrode-use because of uniform velocity distribution. From this comparison, we can expect that the spiral wound type of CDI unit cell would have a high performance deionization capability.

Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor (평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발)

  • Kang, Jeon-Hong;Ryu, Jae-Cheon;Lee, Sang-Hwa;Kim, Kyu-Tae;Kim, Myung-Soo;Han, Sang-Ok;Jung, Jae-Kap
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.9
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.

MnO2 Nanowires Electrodeposited in a Porous Network of Agarose Gel as a Pseudocapacitor Electrode

  • Jin, Sohyun;Ryu, Ilhwan;Lim, Geo;Yim, Sanggyu
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.406-410
    • /
    • 2020
  • Despite a simple preparation of manganese oxide (MnO2) nanowires by electrodeposition, the improvement in specific capacitance (Csp) and voltammetric response of the MnO2 nanowire-based electrodes has been quite limited. This is attributed to the poor electrical conductivity of MnO2 and its dense bulk morphology due to the aggregation of the nanowires. This study investigated the capacitive performance of MnO2 nanowires electrodeposited on agarose thin films. The good ionic conductivity and porous network of the agarose film provided favorable growth conditions for the MnO2 nanowires with suppressed aggregation. A maximum Csp value of 686 F/g measured at a scan rate of 10 mV/s was obtained, which was significantly larger than that of 314 F/g for the agarose-free MnO2 electrode at the same scan rate. The rate capability was also improved. The Csp measured at a high scan rate of 100 mV/s retained 74.0% of the value measured at 10 mV/s, superior to the retention of 71.1% for the agarose-free MnO2 electrode.

The Preparation of Non-aqueous Supercapacitors with LiMn2O4/C Composite Positive Electrodes (LiMn2O4/C 복합 양극을 이용한 비수계 슈퍼커패시터의 제조)

  • Kim, Kyoungho;Yoo, Jeeyoung;Kim, Minsoo;Yeu, Taewhan
    • Korean Chemical Engineering Research
    • /
    • v.45 no.2
    • /
    • pp.178-182
    • /
    • 2007
  • Non-aqueous supercapacitors by using activated C and $LiMn_2O_4$ as an active material in a positive electrode were prepared and characterized. From the cyclic voltammetry and AC impedance analysis, the capacitive effect by electric double layer of activated carbon and the faradic effect by intercalation/deintercalation of $Li^+$ ion were observed. Increasing the ratio of $LiMn_2O_4$, specific capacitances and energy densities of supercapacitor were increased. At the ratio of 0.86:0.14 ($LiMn_2O_4:C$), the maximum specific capacitance of 17.51 Wh/L and energy density of 23.83 F/cc were obtained, which were more than twice of those for a conventional electric double layer capacitor. Even after 1,000 charge/discharge cycle, the supercapacitor by using the electrode containing 14% of activated carbon and 86% of $LiMn_2O_4$ showed 60% better specific capacitance and energy density than that by using the electrode containing 100% activated carbon.

Analysis of Output Characteristics and Frequency Variation Design for Personal High Frequency Electrical Stimulation Medical Devices (개인용 고주파 전기자극기의 주파수 가변 설계 및 출력 특성의 분석)

  • Jang, Kyeong-Wook;Leem, Ji-Hyun;Baek, Seung-Myoung;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • In this paper, personal electrical stimulation medcial devices using bioelectrical stimulating was developed. Therapy effect of RET(resistive electric transfer) was more effective than CET(capacitive electric transfer), but CET was adopted because of safety issue. Then, the optimum parameters that may be effective in thin skin or facial wrinkles was set. For example, the frequency of the pulse voltage for stimulation is 1.8[MHz], burst frequency is 7[kHz] or 400[Hz], the development of devices was to have ON/OFF control and frequency control. When burst frequency was adjusted 7[kHz], heat was generated in the electrode. The case of 400[Hz] the heat was little generated. The microcontroller ATmega128-based experimental results show that the proposed personal high frequency electrical stimulation devices can be applied to medical equipment using therapy effect successfully.

Desalination of Brackish Water by Capacitive Deionization System Combined with Ion-exchange Membrane (이온교환막을 결합한 축전식 탈염 시스템을 이용한 염수의 탈염)

  • Kim, Yu-Jin;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.21 no.1
    • /
    • pp.87-92
    • /
    • 2010
  • Desalination experiments were carried out with two types of cell configuration; a CDI cell constructed with carbon electrodes only and a membrane capacitive deionization (MCDI) cell having a cation-exchange membrane on the cathode surface. The salt removal rate and desalination efficiencies increased linearly with increasing the cell potential. Although the same carbon electrodes were used in the desalination experiments, the MCDI cell showed higher salt removal efficiency than that of the CDI cell. The amount of salt removal for the MCDI cell was enhanced by 33.1~135% compared to the CDI cell, depending on the applied cell potential in the range of 0.8~1.2 V. In addition, the current efficiency for the MCDI cell was about 80%, whereas the efficiency was under 40% for the CDI cell. The higher salt removal efficiency in the MCDI cell was attributed to the fact that ions were selectively transported between the electric double layer and the bulk solution in the MCDI cell configuration.

Fabrication of Capacitive-Type Humidity Sensor with Poly(p-phenylene ether sulfone) (폴리(페닐렌에테르설폰)을 이용한 용량형 습도센서의 제조)

  • Cho, Jae-Ick;Choi, Kyoon;Kim, Chang-Jung;Kim, Byung-Ik;Park, Sueng-Hyun;Bang, Gi-Suk
    • Polymer(Korea)
    • /
    • v.30 no.3
    • /
    • pp.207-209
    • /
    • 2006
  • We fabricated a capacitive-type humidity sensor using poly (p-phenylene ether sulfone: PES) as a humidity sensitive layer. The PES was dissolved in m-cresol $(CH_3C_6H_4OH)$ and spin-coated on ITO-coated glass substrate. Gold was deposited by sputtering as a water-permeable upper electrode. The capacitance of the sensor was inversely proportional to sensing film thicknesses and showed an excellent linearity of less than 1% in the humidity range of 20 to 90%. The sensor haying a $1.4{\mu}m$ sensing layer showed a hysteresis of 1.3% and a good sensitivity of 1.14 at 20 kHz.

Performance Study of Membrane Capacitive Deionization Process Applied by Perfluoropolymer and Aminated Poly(ether imide) Ion Exchange Membranes (불소화고분자와 아민화된 폴리이서이미드 이온교환막을 적용한 축전식 탈염공정의 성능 연구)

  • Kim, Ji Seon;Jeong, Joo Hwan;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.25 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • To investigate the performance of the composite carbon electrodes which the ion exchange polymers were directly casted onto porous carbon electrode surfaces, the adsorption/desorption experiments were carried out by varying the feed concentration, feed flow rate, and desorption voltages for the NaCl solution. When the feed concentration was 100 mg/L, the increase of the adsorption time led to the increase of the salt removal due to the increase of the residence time inside the cell while the increase of the feed flow rate from 15 mL/min to 23 mL/min gave the decrease of the salt removal efficiency, 12% because of the short residence time. When the feed concentration was 200 mg/L, the salt removal was shown 10~15% low because of the incomplete desorption within the desorption intervals.

Studies of Performance and Enlarged Capacity through Multi-stages Stacked Module in Membrane Capacitive Deionization Process (막 축전식 탈염 공정의 다단 적층 모듈을 통한 처리 용량 증대 및 이의 성능 연구)

  • Song, Yye jin;Yun, Won Seob;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.449-457
    • /
    • 2017
  • In this study, the 10 stages stacked module was designed by increasing the number of unit cells in the membrane capacitive deionization(MCDI) process. The aminated polysulfone and sulfonated poly(ether ether ketone) were synthesized and coated on porous carbon electrode by casting method. The salt removal efficiency was measured for the 10 stage stacked module under the operation conditions of adsorption voltage and time, desorption voltage and time, flow rate and concentration of feed water, and di-valent solutions including $CaSO_4$, $MgCl_2$ and tap water. Typically, when 100 mg/L of NaCl as the feed was used, the salt removal efficiency was 98.3% at a flow rate of 100 mL/min, the adsorption condition of 1.2 V/3 min and desorption condition of -0.5 V/5 min.