• Title/Summary/Keyword: canopy base height

Search Result 6, Processing Time 0.019 seconds

Assessment of Canopy Fuel Characteristics for Five Major Coniferous Species in Korea (우리나라 주요 침엽수종의 수관층 연료특성 평가)

  • Kim, Sungyong;Jang, Mina;Lee, Byungdoo;Lee, Youngjin
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.2
    • /
    • pp.247-254
    • /
    • 2013
  • The objective of this study was to assess the canopy fuel characteristics of five major coniferous species in Korea. This study was also developed allometric equations for the canopy fuel load and canopy base height of the major coniferous species using the allomeric equations of biomass developed by the Korea Forest Research Institute and the data from the $5^{th}$ National Forest Inventory. Among the major coniferous fuel types, Pinus koraiensis stands had the highest mean canopy bulk density, 0.34 kg/$m^3$, followed by Gangwon region Pinus densiflora stands 0.28 kg/$m^3$, Pinus thunbergii stands 0.24 kg/$m^3$, Pinus rigida stands 0.15 kg/$m^3$, Central region Pinus densiflora stands 0.12 kg/$m^3$ and Larix leptolepis stands 0.09 kg/$m^3$. The adjusted multiple coefficient of determination of the developed models ranged from 0.6321 to 0.9950 for canopy fuel load and 0.6390 to 0.8539 for canopy base height.

Effects of Forest Tending Works on the Crown Fuel Characteristics of Pinus densiflora S. et Z. Stands in Korea (숲가꾸기 사업이 소나무림의 수관연료특성에 미치는 영향)

  • Kim, Sungyong;Lee, Byungdoo;Seo, Yeonok;Jang, Mina;Lee, Young Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.3
    • /
    • pp.359-366
    • /
    • 2011
  • The objective of this study was to analyze the changes of crown fire hazard possibility from the effects of forest tending works (FTW) in Pinus densiflora stands in Korea. The study sites were located in Youngju (FTW) and Bonghwa (Control) areas. Ten representative sample trees were destructively felled at each areas to analyze the crown fuel characteristics. The results of this study showed that crown fuel moisture content in Youngju and Bonghwa areas were 103.6% and 104.4%, respectively. The needles and twigs with less than 1cm diameter accounted 50.3% of the total crown fuel load in Youngju area and 62.0% in Bonghwa area. On the other hand, it was observed in Youngju that the canopy bulk density was $0.11kg/m^3$ lower but have 1.3 m higher average canopy base height therefore having a possibility of lower crown fire hazard as compared to Bonghwa that had higher canopy bulk density and lower canopy base height.

Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate (도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석)

  • Yeo, In-Ae;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

Modeling Knot Properties for Mongolian Pine in Northeast China

  • Jia, Weiwei;Li, Fengri;Jiang, Lichun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.5
    • /
    • pp.485-491
    • /
    • 2008
  • This study was performed in 14 unthinned Mongolian pine (Pinus sylvestris L. var. mongolica Litvin) plantations in northeast China. Data were collected on 70 sample trees of different canopy position with diameter at breast height (DBH) ranging from 6.9 cm to 34.5 cm. Diameter and length of knots per whorl below the living crown were studied by different vertical levels divided by relative knot height (RHK) in this paper. Models taking DBH and height to the crown base (HCB) as independent variables were developed to predict knot diameter (KD) in a sample whorl. According to the vertical distribution tendency and range of sound knot length (KLsound), KLsound was modeled as multiple linear function of DBH, KD and relative knot height (RHK). The loose knot length (KLloose) was described as a function of DBH, KD and height above the ground for knots (HK) in a mixed log-linear model. Results from this study can provide abundant knot information so as to describe the knot size and vertical distribution tendency of Mongolian pine plantation.

Relation Between the Growth Habitat and the Leaf Quality of Cultivated Mulberry Plants (뽕나무의 생육특성과 엽질과의 관계)

  • 김준호
    • Journal of Plant Biology
    • /
    • v.17 no.3
    • /
    • pp.118-126
    • /
    • 1974
  • Mulberry plants cultivated in mid-Korea were studied on the growth habitat, canopy type, productive structure and vertical light intensity in relation to the quality of mulberry leaves for sericulture. The growth in length of new branch of summer cut mulberry in spring was vigorous on the uppermost of old shoot. Numbers of leaves on a branch were barely 4 leaves on lower than 20th branch from base, but those were 13 leaves on higher than 24th branch. Area of leaves completely expanded was broad on high branch, but narrow on low one. The form of canopy, the type of productive structure and the vertical light distribution depend upon varieties of cultivated mulberry plants were classified according to characteristic of each variety in two groups, respectively; globular and columnar form in canopy, broad leaves and narrow leaves types in productive structure, and seriously obstructured the light and fairly transmitted the light into lower leaf stratum invertical light distribution. Out of varieties of mulberry investigated, Suwon No. 4 and Rosang were belong to the former characters, but Illchiroe and Kaeryangsubun were to the latters. The values of leaf dry matter index and dry matter production produced by leaves were increased in direct proportion to the height of leaf stratum; the leaf dry matter index of the uppermost leaf was twice as much that of the lowest, and the dry matter production by the highest leaf was 17 times compared with that by the lowest leaf. It is assumed that the meagre leaves occurred in the lower leaf stratum of Suwon No. 4 and Rosang were caused to diminished the dry matter index and dry matter production in the under leaves of plant, which were affected by receiving the weak light.

  • PDF

3-Methylthiopropionic Acid of Rhizoctonia solani AG-3 and Its Role in the Pathogenicity of the Fungus

  • Kankam, Frederick;Long, Hai-Tao;He, Jing;Zhang, Chun-hong;Zhang, Hui-Xiu;Pu, Lumei;Qiu, Huizhen
    • The Plant Pathology Journal
    • /
    • v.32 no.2
    • /
    • pp.85-94
    • /
    • 2016
  • Studies were conducted to determine the role of 3-methylthioproprionic acid (MTPA) in the pathogenicity of potato stem canker, Rhizoctonia solani, and the concentrations required to inhibit growth of R. solani under laboratory and plant house-based conditions. The experiments were laid out in a completely randomized design with five treatments and five replications. The treatments were 0, 1, 2, 4, and 8 mM concentrations of MTPA. The purified toxin exhibited maximal activity at pH 2.5 and $30^{\circ}C$. MTPA at 1, 2, 4, and 8 mM levels reduced plant height, chlorophyll content, haulm fresh weight, number of stolons, canopy development, and tuber weight of potato plants, as compared to the control. MTPA significantly affected mycelial growth with 8 mM causing the highest infection. The potato seedlings treated with MTPA concentrations of 1.0-8.0 mM induced necrosis of up to 80% of root system area. Cankers were resulted from the injection of potato seedling stems with 8.0 mM MTPA. The results showed the disappearance of cell membrane, rough mitochondrial and cell walls, change of the shape of chloroplasts, and swollen endoplasmic reticulum. Seventy-six (76) hours after toxin treatment, cell contents were completely broken, cytoplasm dissolved, and more chromatin were seen in the nucleus. The results suggested that high levels of the toxin concentration caused cell membrane and cytoplasm fracture. The integrity of cellular structure was destroyed by the phytotoxin. The concentrations of the phytotoxin were significantly correlated with pathogenicity and caused damage to the cell membrane of potato stem base tissue.