• 제목/요약/키워드: canal

검색결과 2,140건 처리시간 0.038초

3-dimensional reconstruction of mandibular canal at the interforaminal region using micro-computed tomography in Korean

  • Jeon, Yong Hyun;Lee, Chul Kwon;Kim, Hee-Jung;Chung, Jae-Heon;Kim, Heung-Joong;Yu, Sun-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.470-475
    • /
    • 2017
  • PURPOSE. The purpose of this study was to identify the complex course of the mandibular canal using 3D reconstruction of microCT images and to provide the diagram for clinicians to help them understand at the interforaminal region in Korean. MATERIALS AND METHODS. Twenty-six hemimandibles obtained from cadavers were examined using microCT, and the images were reconstructed. At both the midpoint of mental foramen and the tip of anterior loop, the bucco-lingual position, the height from the mandibular inferior border, the horizontal distance between two points, and position relative to tooth site on the mandibular canal were measured. The angle that the mental canal diverges from the mandibular canal was measured in posterior-superior and lateral-superior direction. RESULTS. The buccal distance from the mandibular canal was significantly much shorter than lingual distance at both the mental foramen and the tip of anterior loop. The mandibular canal at the tip of anterior loop was significantly located closer to buccal side and higher than at the mental foramen. And the mental canal most commonly diverged from the mandibular canal below the first premolar by approximately $50^{\circ}$ posterior-superior and $41^{\circ}$ lateral-superior direction, which had with a mean length of 5.19 mm in front of the mental foramen, and exited to the mental foramen below the second premolar. CONCLUSION. These results suggest that it could form a hazardous tetrahedron space at the interforaminal region, thus, the clinician need to pay attention to the width of a premolar tooth from the mental foramen during dental implant placement.

근관형성 기구 및 방법에 따른 근관 형태의 변화 (CHANGES IN ROOT CANAL CONFIGURATION USING DIFFERENT FILE TYPES AND TECHNIQUES)

  • 허영주;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.291-304
    • /
    • 1997
  • The purposes of this study were to evaluate the changes in root canal configuration with canal instrumentation using different file types and techniques and to investigate most appropriate instrumentation technique in maintaining the original canal configuration with different file types. Fifty curved mesiobuccal or distobuccal canals of extracted human maxillary molar teeth were instrumented using a step-back technique with stainless steel K-files or nickel-titanium K-files, a crown-down pressureless technique with stainless steel K-files or nickel-titanium K-files and nickel-titanium engine-driven files. Radiographs were taken before and after instrumentation using a specially designed device that allowed for the pre-and postinstrumentation canals to be taken with the same X-ray angulation. Magnified X-ray images on a magnifier screen were traced and post instrumentation canal images were compared with the preinstrumentation ones. Changes in canal curvature and the incidence of procedural accidents were analyzed. The results were as follows : Crown-down pressureless technique with nickel-titanium K-files and nickel-titanium engine-driven filing produced no significant changes in canal curvature (p>0.05), while the step-back technique with stainless steel K-files or nickel-titanium K-files (p<0.01) and the crown-down pressureless technique with stainless steel K-files (p<0.05) produced significant changes. With nickel-titanium K-file, crown-down pressureless technique produced significantly less changes in canal curvature than step-back technique (p<0.05), while there was no significant difference between techniques with stainless steel K-files (p>0.05). File types exerted no significant influences in the changes of canal curvature both in the step-back technique and crown-down pressureless technique (0>0.05). Regardless of the file types used, step-back technique produced more procedural accidents such as ledge or elbow formation, apical zipping and apical transportation than the crowndown pressureless technique and nickel-titanium engine-driven filing. Both with stainless steel K-files and with nickel-titanium K-files, the incidence of apical extrusion of canal debris was higher in step-back technique than in crown-down pressureless technique.

  • PDF

Prevalence and features of distolingual roots in mandibular molars analyzed by cone-beam computed tomography

  • Choi, Mi-Ree;Moon, Young-Mi;Seo, Min-Seock
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.221-226
    • /
    • 2015
  • Purpose: This study evaluated the prevalence of distolingual roots in mandibular molars among Koreans, the root canal system associated with distolingual roots, and the concurrent appearance of a distolingual root in the mandibular first molar and a C-shaped canal in the mandibular second molar. Materials and Methods: Cone-beam computed tomographic images of 264 patients were screened and examined. Axial sections of 1056 mandibular molars were evaluated to determine the number of roots. The interorifice distances from the distolingual canal to the distobuccal canal were also estimated. Using an image analysis program, the root canal curvature was calculated. Pearson's chi-square test, the paired t-test, one-way analysis of variance, and post-hoc analysis were performed. Results: Distolingual roots were observed in 26.1% of the subjects. In cases where a distolingual root was observed in the mandibular molar, a significant difference was observed in the root canal curvature between the buccolingual and mesiodistal orientations. The maximum root canal curvature was most commonly observed in the mesiodistal orientation in the coronal portion, but in the apical portion, maximum root canal curvature was most often observed in the buccolingual orientation. Conclusion: The canal curvature of distolingual roots was found to be very complex, with a different direction in each portion. No correlation was found between the presence of a distolingual root in the mandibular first molar and the presence of a C-shaped canal in the mandibular second molar.

기계적 협착부를 갖는 근관에서 Root-ZX의 정확도에 관한 연구 (A STUDY ON THE ACCURACY OF THE ROOT-ZX IN THE CANAL WITH MECHANICALLY FORMED CONSTRICTION)

  • 김병현;이영규;김용식
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.628-632
    • /
    • 1999
  • Currently electronic apex locators have been widely used to determine working length in endodontic treatment. According to Manufacture's recommendation, it is beneficial to find the working length before instrumenting the canal. However, in crown-down pressureless technique, working length of tooth is established following coronal instrumentation 3mm short of radiographic apex. In narrow canals, mechanically formed constriction might be established by coronal instrumentation in some distance from anatomical constriction. The purpose of this study was to evaluate the accuracy of Root-ZX in the canal with mechanical constriction following considerable coronal enlargement with ProFile .06 series. The 40 root canals in 30 extracted mandibular molars were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an acrylic container with normal saline. The initial canal length(IL) was measured with Root-ZX by negotiating a size 10 file to the apical constriction. The canal was sequentially enlarged to size 40 with ProFile .06 file 3mm short of actual length. The enlarged final canal lengths (FL) were obtained with a size 15 file. The average values of IL, FL were calculated and compared using Repeated measures Analysis of Variance followed Turkey's Studentized Range test. The results were obtained as follows: 1. The initial canal length was 0.12mm shorter than actual canal length(P>0.05). 2. The differences between initial canal length and final canal length were not significant(P>0.05). 3. As a result of this study, regardless of mechanically formed constriction. Root-ZX differentiated between mechanical and anatomic constriction.

  • PDF

근관확대 및 세척 주사바늘의 근관 내 위치가 치근단 3 mm 부위의 근관 세정에 미치는 영향 (Effects of canal enlargement and irrigation needle depth on the cleaning of the root canal system at 3 mm from the apex)

  • 문호진;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제37권1호
    • /
    • pp.24-28
    • /
    • 2012
  • Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of ${\times}250$, ${\times}500$, ${\times}1,000$, ${\times}2,500$ were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.

국토개발측면에서 구상해본 한국의 "내륙운하"건설 (The Land Canal Construction of Korea in the Vision of the National Land Development)

  • 정무용
    • 기술사
    • /
    • 제39권6호
    • /
    • pp.51-56
    • /
    • 2006
  • The important role of canal is moving goods and the canals from all over the world has contributed much to method of transporting goods. But, the canal system accounts rfor 25% of the total moving goods. One of its main goals is to reduce overland transportation costs were 30% more expensive than moving goods over water. We plan to build a Korea inland canal system and need to from a scheme of building a multi canal. We should consider positive aspect of this plan, on the other hand a study of the conal's environmental impact is required prior to beginning any construction. Finally, offer our opinion on the vision of Korea inland canal that aspect5 of national land development.

  • PDF

다공성 황토블록을 이용한 친환경 배수로공법 개발연구 (A Study on the Environment Friendly Canal Construction Method using Porous Loess Block)

  • 최경영;성현제;은재기;양영철;김채수;엄대호;김선주
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.147-150
    • /
    • 2003
  • According to development and urbanization of country, environment and ecosystem were ignored during the past thirty years. Therefore canal, which had been developed by concrete, is remained as the space where life can not alive any longer. In this study, Environmental friendly canal construction method using porous loess block are investigated. Porous loess blocks are which is developing focused on both scenery and hydraulic safty. Canal using Porous loess blocks can take a vegetation's distribution and improvement of soil properties and hydraulic safty of bank. In this study, The examination of applied canal construction method using porous loess block that is considering vegetation's distribution and properties of material is done to present development of environmental friendly canal construction method.

  • PDF

용배수로의 환경친화적 정비기법 (Environment-Friendly Development System of Irrigation ditch and Drainage canal)

  • 김채수;엄대호;한경수;전택기;김선주;최경영
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.107-110
    • /
    • 2003
  • In this article we developed the environment-friendly arrangement system of drainage and irrigation canal. It is divided into the model which considers ecological conservation type, irrigation flood control type and hydrophilic type. In canal plan and design we will consider vertical section and intersection plan, water quality management, waterside environment construction plan, canal terminal treatment, canal bottom plan, etc. Consequently, We propose the detail contents which must be considered when we plan the environmental canal space.

  • PDF

A Case of Engorged Female Hard Tick in the External Auditory Canal of an Infant

  • Sung, Woo-Jung;Kim, Yee-Hyuk
    • Parasites, Hosts and Diseases
    • /
    • 제55권5호
    • /
    • pp.565-568
    • /
    • 2017
  • An oval-shaped mass with a smooth surface was found in the ear canal of a 22-month-old male infant. Although the mass appeared to be almost entirely blocking the ear canal, it was successfully removed under a surgical microscope without general anesthesia at the outpatient department. Under an optical microscope with hematoxylin and eosin staining, the specimen was observed to have a cuticle with a serrated surface and a pore canal, as well as parts of the capitulum, salivary glands, muscles, midgut, and the legs. The specimen was identified as a hard tick of the family Ixodidae, based on gross and histological findings. This paper is the first report in Korea on the diagnosis and treatment of a tick bite in the ear canal.

수종(數種) 근관형성기구(根管形成器具)의 근관정화효과(根管淨化效果)에 관(關)한 실험적(實驗的) 연구(硏究) (A STUDY ON THE CLEANSING EFFECT OF THREE ROOT CANAL INSTRUMENTS)

  • 임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.193-198
    • /
    • 1984
  • This study was conducted to compare the chip removal capability of root canal enlarging instruments. Fifty five buccal or mesial canals from upper and lower molar teeth were randomly selected and divided into three groups; Reamer, K-type file and K-flex file. Fifteen canals in each group were individually enlarged with one of three tested instruments and irrigated with 5cc of normal saline solution. After instrumentation, each canal was dried with paper point and the canal was splited longitudinally and the cleanness of root canal surface was evaluated under stereoscope by three observers. The results were as follows; 1. Most of the canals experimented showed varying degree of the presence of debris. 2. The canals prepared with reamers showed the most clean canal surface. 3. There was no significant difference in debridement effect between k-type file and k-flexfile.

  • PDF