• Title/Summary/Keyword: camera exposure

Search Result 166, Processing Time 0.024 seconds

ALL-SKY OBSERVATION OF THE 2001 LEONID METEOR STORM: 1. METEOR MAGNITUDE DISTRIBUTION (전천 카메라를 이용한 2001 사자자리 유성우 관측: 1. 유성 등급 분포)

  • 김정한;정종균;김용하;원영인;천무영;임홍서
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.4
    • /
    • pp.283-298
    • /
    • 2003
  • The 2001 Leonid meteor storm has been observed all over the world, and its most intense flux since the last few decades has caused great interest among both laymen and experts. Especially, its maximum hours occurred at dawn hours of Nov. 19 in the east Asia, during which moonless clear night at the Mt. Bohyun allowed us near perfect condition of observation. Observation was carried out in the period of 01:00∼05:40(KST), which include the predicted maximum hours, with all-sky camera installed for upper atmospheric airglow research. Tn this paper we analyze 68 all-sky images obtained in this period, which contain records of 172 meteors. Utilizing the zenith hourly rate(ZHR) of 3000 and magnitude distribution index of 2, which were reported to International Meteor Organization by visible observers in the east Asia, we estimate the limiting magnitude of about 3 for meteors detected in our all-sky images. We then derive magnitudes of 83 meteors with clear pixel brightness outlines among the initially detected 172 meteors by comparing with neighbor standard stars. Angular velocities of meteors needed for computing their passing times over an all-sky image are expressed with a simple formula of an angle between a meteor head and the Leonid radiant point. The derived magnitudes of 83 meteors are in the range of -6∼-1 magnitude, and its distribution shows a maximum new -3mag. The derived magnitudes are much smaller than the limiting magnitude inferred from the comparison with the result of naked-eye observations. The difference may be due to the characteristic difference between nearly instantaneuous naked-eye observations and CCD observations with a long exposure. We redetermine magnitudes of the meteors by adjusting a meteor lasting time to be consistent with the naked-eye observations. The relative distribution of the redetermined magnitudes, which has a maximum at 0 mag., resembles that of the magnitudes determined with the in-principle method. The relative distribution is quite different from ones that decrease monotonically with decreasing magnitudes for meteors(1∼6) sensitive to naked-eye observations. We conclude from the magnitude distribution of our all-sky observation that meteors brighter than about 0 mag., appeared more frequently during the 2001 Leonid maximum hours. The frequent appearance of bright meteors has significantly important implication for meteor research. We noted, however, considerably large uncertainties in magnitudes determined only by comparing standard stars due to the unknown lasting time of meteors and the non-linear sensitivity of all-sky camera.

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF

Rock Joint Trace Detection Using Image Processing Technique (영상 처리를 이용한 암석 절리 궤적의 추적)

  • 이효석;김재동;김동현
    • Tunnel and Underground Space
    • /
    • v.13 no.5
    • /
    • pp.373-388
    • /
    • 2003
  • The investigation on the rock discontinuity geometry has been usually undergone by direct measurement on the rock exposures. But this sort of field work has disadvantages, which we, for example, restriction of surveying areas and consuming excessive times and labors. To cover these kinds of disadvantages, image processing could be regarded as an altemative way, with additional advantages such as automatic and objective tools when used under adequate computerized algorithm. This study was focused on the recognition of the rock discontinuities captured in the image of rock exposure by digital camera and the production of the discontinuity map automatically. The whole process was written using macro commands builtin image analyzer, ImagePro Plus. ver 4.1(Media Cybernetic). The procedure of image processing developed in this research could be divided with three steps, which are enhancement, recognition and extraction of discontinuity traces from the digital image. Enhancement contains combining and applying several filters to remove and relieve various types of noises from the image of rock surface. For the next step, recognition of discontinuity traces was executed. It used local topographic features characterized by the differences of gray scales between discontinuity and rock. Such segments of discontinuity traces extracted from the image were reformulated using an algorithm of computer decision-making criteria and linked to form complete discontinuity traces. To verify the image processing algorithms and their sequences developed in this research, discontinuity traces digitally photographed on the rock slope were analyzed. The result showed about 75~80% of discontinuities could be detected. It is thought to be necessary that the algorithms and computer codes developed in this research need to be advanced further especially in combining digital filters to produce images to be more acceptable for extraction of discontinuity traces and setting seed pixels automatically when linking trace segments to make a complete discontinuity trace.

Design of Real-Time PreProcessor for Image Enhancement of CMOS Image Sensor (CMOS 이미지 센서의 영상 개선을 위한 실시간 전처리 프로세서의 설계)

  • Jung, Yun-Ho;Lee, Joon-Hwan;Kim, Jae-Seok;Lim, Won-Bae;Hur, Bong-Soo;Kang, Moon-Gi
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.62-71
    • /
    • 2001
  • This paper presents a design of the real-time digital image enhancement preprocessor for CMOS image sensor. CMOS image sensor offers various advantages while it provides lower-quality images than CCD does. In order to compensate for the physical limitation of CMOS sensor, the spatially adaptive contrast enhancement algorithm was incorporated into the preprocessor with color interpolation, gamma correction, and automatic exposure control. The efficient hardware architecture for the preprocessor is proposed and was simulated in VHDL. It is composed of about 19K logic gates, which is suitable for low-cost one-chip PC camera. The test system was implemented on Altera Flex EPF10KGC503-3 FPGA chip in real-time mode, and performed successfully.

  • PDF

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF

The Study of Aerial Triangulation Using GPS (GPS를 이용한 사진기준점 측랑에 관한 연구)

  • 이재원;문두열;김정희;김진수
    • Spatial Information Research
    • /
    • v.12 no.2
    • /
    • pp.181-191
    • /
    • 2004
  • Nowadays, GPS-photogrammetry can be applied to the basemap production, a land register and NGIS. And from now on, as the increase of GPS receiver rate, the study on the interpolation methods considering the exact movement of an aircraft at photoflight and the study on the supplement of GPS defect by INS are required continuously. GPS-Photogrammetry, which are based on the direct measurement of the projection centers and attitude at the moment of camera exposure time through loading the GPS receiver in aircraft. This photogrammetric methods can of for us to acquire the exterior orientation parameters with only minimum ground control points, even the ground control process could be completely skipped. Consequently, we can drastically reduce the time and cost far the mapping process. In this thesis, two test flights were conducted in area to evaluate the performance of accuracy and efficiency through the analysis of results between the two photogrammetric methods, that is, traditional photograrammetry, GPS-Photogrammetry. Test results shows that a large variety of advantages of GPS-Photogrammetry against traditional photogrammetry is to be verified. Especially, the number of ground control points for the exterior orientation could be saved more than 70~80%, and the cost far map production 30~50%, respectively. In addition, it was convinced that the large reduction of control points has not any effect on the block accuracy.

  • PDF

Geospatial Data Display Technique for Non-Glasses Stereoscopic Monitor (무안경식 입체 모니터를 이용한 지형공간 데이터의 디스플레이 기법)

  • Lee, Seun-Geun;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.6
    • /
    • pp.599-609
    • /
    • 2008
  • Development of computer and electronic technology leads innovative progress in spatial informatics and successful commercialization. Geospatial information technology plays an important role in decision making in various applications. However, information display media are two-dimensional plane that limits visual perception. Understanding human visual processing mechanism to percept stereo vision makes possible to implement three-dimensional stereo image display. This paper proposes on-the-fly stereo image generation methods that are involved with various exterior and camera parameters including exposure station, viewing direction, image size, overlap and focal length. Collinearity equations and parameters related with stereo viewing conditions were solved to generate realisitc stereo imagery. In addition stereo flying simulation scenery was generated with different viewing locations and directions. The stereo viewing is based on the parallax principle of two veiwing locations. This study implemented anaglyphic stereogram, polarization and lenticular stereo display methods. Existing display technology has limitation to provide visual information of three-dimensional and dynamic nature of the real world because the 3D spatial information is projected into 2D plane. Therefore, stereo display methods developed in this study improves geospatial information and applications of GIS by realistic stereo visualization.

A Study on the transition of Explosion to Eire of LPG and Its' Prevention (LP가스 폭발 후 화재 전이 현상 및 전이 방지에 관한 연구)

  • 오규형;이성은
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.20-26
    • /
    • 2004
  • The purpose of this study is to investigate the transition mechanism and prevention mechanism of gas explosion to fire. Transition phenomena of explosion to fire of LPG in the explosion vessel of its size of TEX>$100 cm {\times} 60 cm {\times} 45 cm$ was visualized using the high speed video camera and the mechanism was analysed from the videograph. Newspaper size of $30cm {\times} 20cm$ was used for combustible sample in this experiments and LPG-air mixture was ignited by 10 ㎸ electric spark. Experimental parameter was gas concentration, size of vent area and position of combustible solid. Size of vent area were varied as $10cm {\times} 9cm, 13cm {\times} 10cm, 27cm {\times} 20cm, 40cm {\times} 27cm$, and the position of combustible was varied in 4 point. Carbon dioxide was used to study the prevention mechanism of explosion to fire transition of LPG. Based on this experiment we can find that transition possibility of explosion to fire on solid combustible from explosion is depends on concentration of LPG-air mixture and the exposure time of solid combustibles in high temperature atmosphere of flame and burnt gas. And cooling or inerting of the atmosphere after explosion can be prevent the transition of explosion to fire on solid combustibles from gas explosion.

A Study on the Risk of Halogen Lamp for Pigsty Heating and Fire Prevention (축사 난방용 할로겐램프의 위험성 및 화재 예방에 관한 연구)

  • Lee, Jae kyung;Seo, Seong Hyeon;Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.553-564
    • /
    • 2021
  • This study analyzed the the risk of halogen lamp for pigsty heating and its fire prevention. Halogen lamps are used for keeping warm in pen because of their excellent economy and convenience. However, there is a high risk of fire due to poor safety management and exposure to animal movements. In fact, after exploring old pigsty and cattle shed, it was easy to confirm that they were exposed to fire risks. We noted this point and studied the possibility of fire by experiment due to combustible contact with halogen lamp and carelessness in use. The experiment was conducted under conditions similar to the actual use environment. After installing halogen lamps to the height used in actual pen, the temperature change was observed with infrared camera with straw, sawdust and rice husks on the floor. And assuming abnormal conditions, the experiment was also conducted under conditions the lamp dropped on the floor or combustible material came into contact with the glass tube inside the lamp. If halogen lamps were used in normal condition, there was no risk of fire. However, in abnormal use environments, smoke comes out or even ignited. Even if it is convenient for use or highly utilized, high risk of fire will require setting up fire prevention measures or regulation of use. Through in-depth fire investigation and research, we should promote the risk of fire and make efforts to prevent fire to minimize human life and property damage.