A systematic approach to the calibration of micro-parameters for the flat-jointed bonded particle model

  • Zhou, Changtai;Xu, Chaoshui;Karakus, Murat;Shen, Jiayi
    • Geomechanics and Engineering
    • /
    • v.16 no.5
    • /
    • pp.471-482
    • /
    • 2018
  • A flat-jointed bonded-particle model (BPM) has been proved to be an effective tool for simulating mechanical behaviours of intact rocks. However, the tedious and time-consuming calibration procedure imposes restrictions on its widespread application. In this study, a systematic approach is proposed for simplifying the calibration procedure. The initial relationships between the microscopic, constitutive parameters and macro-mechanical rock properties are firstly determined through dimensionless analysis. Then, sensitivity analyses and regression analyses are conducted to quantify the relationships, using results from numerical simulations. Finally, four examples are used to demonstrate the effectiveness and robustness of the proposed systematic approach for the calibration procedure of BPMs.

Error Analysis and Modeling of Airborne LIDAR System (항공라이다시스템의 오차분석 및 모델링)

  • Yoo Byoung-Min;Lee Im-Pyeong;Kim Seong-Joon;Kang In-Ku
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.199-204
    • /
    • 2006
  • Airborne LIDAR systems have been increasingly used for various applications as an effective surveying mean that can be complementary or alternative to the traditional one based on aerial photos. A LIDAR system is a multi-sensor system consisting of GPS, INS, and a laser scanner and hence the errors associated with the LIDAR data can be significantly affected by not only the errors associated with each individual sensor but also the errors involved in combining these sensors. The analysis about these errors have been performed by some researchers but yet insufficient so that the results can be critically contributed to performing accurate calibration of LIDAR data. In this study, we thus analyze these error sources, derive their mathematical models and perform the sensitivity analysis to assess how significantly each error affects the LIDAR data. The results from this sensitivity analysis in particular can be effectively used to determine the main parameters modelling the systematic errors associated with the LIDAR data for their calibration.

  • PDF

High Temperature Sensitivity Characteristics of the Voltage Type High Temperature Piezoelectric Accelerometer (고온용 전압형 가속도센서의 온도특성)

  • Kim, Y.D.;Kim, K.I.;Jung, W.C.;Koh, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1285-1287
    • /
    • 1998
  • Vibration measurements to monitor the condition of machinery and machine elements offers several advantages over traditional methods of nondestructive evaluation. RIST(Research Institute of Industrial Science & Technology) has established a calibration system for accelerometers that measures within a frequency range from 2Hz to 6,300Hz and a temperature range from $-40^{\circ}C$ to $180^{\circ}C$. The calibration procedures are based on the principle of the comparison method. To monitor vibration signals of machinery and machine elements, annular shear type piezoelectric accelerometers employing solid state microelectronics were fabricated. The voltage sensitivity and resonant frequency of fabricated accelerometers was 83mV/g, 23kHz, respectively. This paper discusses the method of fabrication of annular shear type piezoelectric accelerometers and the results of field tests in POSCO(Pohang Iron & Steel Co. LTD.).

  • PDF

Application of the uncertainty for insertion loss measurement of silencers (소음기 감음 성능 불확도 산출 방법 연구)

  • Yu, Seung-Guk;Kim, Dae-Hyeon;Kim, Yeong-Chan;Kim, Du-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1675-1680
    • /
    • 2000
  • Recently the uncertainty has been made rapid progress in various fields of industry but the uncertainty measurement method of acoustical test (i.e. Insertion loss, Absorption ratio, Transmission loss etc,) hasn't been established. In this study, the uncertainty of measurement method for ducted silencers is carried out according to ISO 7235. The standard uncertainty factors are composed of sound pressure level, microphone sensitivity and pistonphone calibration in this measurement. Sound pressure level is type A evaluation of uncertainty, microphone sensitivity and pistonphone calibration are type B evaluation of uncertainty. The combined standard uncertainty is calculated by two type evaluation. The expanded uncertainty is expressed by the combined standard uncertainty multiply k value which is yield the effective degree of freedom.

  • PDF

Development of Measuring Device for Electric Field on the Ground Level Using a Field Mill (필드 밀을 이용한 대지전장 측정장치 개발)

  • 송재용;김명진;길경석;천상규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.469-473
    • /
    • 2001
  • This paper describes a rotation-type field mill to measure the electric field intensity caused by thunderclouds on the ground level. The field mill developed is consisted of two isolated electrode vanes, a grounded stator and a rotor. To develop a high sensitive field mill, the principles and design rules of a rotation-type field mill are studied. Also, two types of calibration system, such as a cylindrical guard electrodes and a parallel-plate electrodes, are proposed to determine the sensitivity and frequency bandwidth of the field mill. From the calibration experiment, the frequency bandwidth and the sensitivity of the field mill arc DC ∼ 200 [MHz] and 0.267 [mV/Vm], respectively. Therefore, it can measure the electric field intensity from 73[V/m] to 18.7[kV/m].

  • PDF

The General Analysis of an Active Stereo Vision with Hand-Eye Calibration (핸드-아이 보정과 능동 스테레오 비젼의 일반적 해석)

  • Kim, Jin Dae;Lee, Jae Won;Sin, Chan Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.83-83
    • /
    • 2004
  • The analysis of relative pose(position and rotation) between stereo cameras is very important to determine the solution that provides three-dimensional information for an arbitrary moving target with respect to robot-end. In the space of free camera-model, the rotational parameters act on non-linear factors acquiring a kinematical solution. In this paper the general solution of active stereo that gives a three-dimensional pose of moving object is presented. The focus is to achieve a derivation of linear equation between a robot′s end and active stereo cameras. The equation is consistently derived from the vector of quaternion space. The calibration of cameras is also derived in this space. Computer simulation and the results of error-sensitivity demonstrate the successful operation of the solution. The suggested solution can also be applied to the more complex real time tracking and quite general and are applicable in various stereo fields.

The General Analysis of an Active Stereo Vision with Hand-Eye Calibration (핸드-아이 보정과 능동 스테레오 비젼의 일반적 해석)

  • 김진대;이재원;신찬배
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.89-90
    • /
    • 2004
  • The analysis of relative pose(position and rotation) between stereo cameras is very important to determine the solution that provides three-dimensional information for an arbitrary moving target with respect to robot-end. In the space of free camera-model, the rotational parameters act on non-linear factors acquiring a kinematical solution. In this paper the general solution of active stereo that gives a three-dimensional pose of moving object is presented. The focus is to achieve a derivation of linear equation between a robot's end and active stereo cameras. The equation is consistently derived from the vector of quaternion space. The calibration of cameras is also derived in this space. Computer simulation and the results of error-sensitivity demonstrate the successful operation of the solution. The suggested solution can also be applied to the more complex real time tracking and quite general and are applicable in various stereo fields.

Calibration of APEX-Paddy Model using Experimental Field Data

  • Mohammad, Kamruzzaman;Hwang, Syewoon;Cho, Jaepil;Choi, Soon-Kun;Park, Chanwoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.155-155
    • /
    • 2019
  • The Agricultural Policy/Environmental eXtender (APEX) models have been developed for assessing agricultural management efforts and their effects on soil and water at the field scale as well as more complex multi-subarea landscapes, whole farms, and watersheds. National Academy of Agricultural Sciences, Wanju, Korea, has modified a key component of APEX application, named APEX-Paddy for simulating water quality with considering appropriate paddy management practices, such as puddling and flood irrigation management. Calibration and validation are an anticipated step before any model application. Simple techniques are essential to assess whether or not a parameter should be adjusted for calibration. However, very few study has been done to evaluate the ability of APEX-Paddy to simulate the impact of multiple management scenarios on nutrients loss. In this study, the observation data from experimental fields at Iksan in South Kora was used in calibration and evaluation process during 2013-2015. The APEX auto- calibration tool (APEX-CUTE) was used for model calibration and sensitivity analysis. Four quantitative statistics, the coefficient of determination ($R^2$),Nash-Sutcliffe(NSE),percentbias(PBIAS)androotmeansquareerror(RMSE)were used in model evaluation. In this study, the hydrological process of the modified model, APEX-Paddy, is being calibrated and tested in predicting runoff discharge rate and nutrient yield. Field-scale calibration and validation processes are described with an emphasis on essential calibration parameters and direction regarding logical sequences of calibration steps. This study helps to understand the calibration and validation way is further provided for applications of APEX-Paddy at the field scales.

  • PDF

Analysis of Surface Profile using Gap Sensor (Gap 센서를 이용한 가공물의 표면특성 분석)

  • 송무건;유송민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.304-308
    • /
    • 2000
  • Surface roughness measurement system with capacitance type gap sensor. Tentative result from the calibration measurement showed the potential applicability of the sensor to the processed specimen. In order to test the sensitivity of the measurement system, several parameters including valley depth, width of the specimen have been changed. Effect of the charge area between sensor and specimen surface has been also analyzed.

  • PDF