• 제목/요약/키워드: calibration of transducer

검색결과 67건 처리시간 0.029초

심자도 신호 검출을 위한 Flux Locked Loop (FLL) Emulation 회로 (Emulator Circuit for a Flux Locked Loop for Detection of Magnetocardiography Signal)

  • 안창범;이동훈;김인기;장경섭;김기태;정동현;최중필
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2749-2752
    • /
    • 2003
  • Magnetocardiography is a very weak biomagnetic field generated from the heart. Since the magnitude of the biomagnetic field is in the order of a few pico Tesla, it is measured with a superconducting quantum interference device (SQUID). SQUID is a transducer converting magnetic flux to voltage, however, its range of linear conversion is very restricted. In order to overcome the narrow dynamic range. a flux locked loop is used to feedback the output field with opposite polarity to the input field so that the total Held becomes zero. This prevents the operating point of the SQUID from moving too far away from the null point thereby escape from the linear region. In this paper, an emulator for the SQUID sensor and feedback coil is proposed. Magnetic courting between the original field and the generated field by the feedback coil is emulated by electronic circuits. By using the emulator, FLL circuits are analyzed and optimized without SQUID sensors. The emulator may be used as a test signal for multi-channel gain calibration and system maintenance.

  • PDF

휴대용 어음청력검사 시스템 구현 (Development of Ambulatory Speech Audiometric System)

  • 신승원;김경섭;이상민;임원진;이정환;김동준
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.645-654
    • /
    • 2009
  • In this study, we present an efficient ambulatory speech audiometric system to detect one's hearing problems at an earlier stage as possible without his or her visit to the audiometric testing facility such in a hospital or a clinic. To estimate a person's hearing threshold level in terms of speech sound response in his or her local environment, a digital assistant(PDA) device is used to generate the speech sound with implementing audiometric Graphic User Interface(GUI) system. Furthermore, a supra-aural earphone is used to measure a subject's hearing threshold level in terms of speech sound by the compensating the transducer's gain by adopting speech sound calibration system.

IEEE 1451.4를 이용한 전자혀 시스템의 표준화 방안 (The way to standardize electronic tongue system using IEEE 1451.4)

  • 김동진;김정도;변형기;함유경;한동원
    • 센서학회지
    • /
    • 제14권6호
    • /
    • pp.444-454
    • /
    • 2005
  • The IEEE 1451.4 standards defines an architectural model for interfacing smart transducers for sensors & actuators. This standard allows analogue transducers to communicate their identification and calibration data in a digital format. A digital format is called the TEDS (transducer electronic data sheet). However, the standard template TEDS of IEEE 1451.4 do not supports sensors to use in electronic tongue system, such as arrayed-potentiometric and voltametric sensors. In this paper, a solution to standardize sensors for E-Tongue (electronic tongue) and electronic tongue systems is presented.

전기용량법에 의한 자기이방성 측정장치 (A Measurement System for Magnetic Anisotropy with Capacitance Method)

  • 이용호;이연숙;신용돌;문기원;노태환;김희중;강일구
    • 한국자기학회지
    • /
    • 제1권1호
    • /
    • pp.30-36
    • /
    • 1991
  • 전기용량법에 의한 자기이방성 측정장치를 설계 제작하였다. 균이자기장 속에서 원판 또는 구형의 시료가 자기이방성에 의해 받는 토오크를 평행판 축전기의 미소용량 변화로 변환하여, 그것을 변압기 부리지 로 검출하였다. 3% Si-Fe 단결정의(100)면에 대한 입방 이방성 $K_{1}$$3.3{\times}10^{4}\;J/m^{3}$가 얻어졌으며, 교정에는 Ni선의 형상이방성을 이용하였다. 기타 수종의 시료에 대한 결과도 기존치와 좋은 일치를 보였다.

  • PDF

IEEE 1451.4를 이용한 전자코 시스템의 인터페이스 방안 (The way to interface for electronic nose using IEEE 1451.4)

  • 김동진;김정도;변형기;정영창;함유경;정우석;이정환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.123-126
    • /
    • 2005
  • The IEEE 1451.4 standards defines an architectural model for interfacing smart transducers for sensors & actuators. This standard allows analogue transducers to communicate their identification and calibration data in a digital format. A digital format is called TEDS(transducer electronic data sheet). However, the standard template of IEEE 1451.4 TEDS do not supports gas sensors to use in electronic nose system, such as array sensors. In this paper, a solution to standardize sensors for electronic nose systems is presented.

  • PDF

호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술 (Respiratory air flow measuring technique without sensing element on the flow stream)

  • 이인광;박준오;이수옥;신은영;김경천;김경아;차은종
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

호흡 감지를 위한 복부 부착형 전도성 고무소자의 계측특성 (Characteristics of conductive rubber belt on the abdomen to monitor respiration)

  • 김경아;김성식;조동욱;이승직;이태수;차은종
    • 센서학회지
    • /
    • 제16권1호
    • /
    • pp.24-32
    • /
    • 2007
  • Conductive rubber material was molded in a belt shape to measure respiration. Its resistivity was approximately $0.03{\;}{\Omega}m$ and the resistance-displacement relationship showed a negative exponent. The temperature coefficient was approximately $0.006{\;}k{\Omega}/^{\circ}C$ negligible when practically applied on the abdomen. The conductive rubber belt was applied on a normal male's abdomen with the dimensional change measured during resting breathing. The abdominal signal was differentiated ($F_{m}$) and compared with the accurate standard air flow rate signal ($F_{s}$) obtained by pneumotachometry. $F_{m}$ and $F_{s}$ differed in waveform, but the start and end timings of each breaths were clearly synchronized, demonstrating that the respiratory frequency could be accurately estimated before further processing of $F_{m}$. $F_{m}-F_{s}$ loop showed a nonlinear hysteresis within each breath period, thus 6 piecewise linear approximation was performed, leading to a mean relative error of 14 %. This error level was relatively large for clinical application, though customized calibration seemed feasible for monitoring general variation of ventilation. The present technique would be of convenient and practical application as a new wearable respiratory transducer.

자기결합방식의 이식형 인공중이의 제안 (Proposal of Magnetic Coupling Type Implantable Middle Ear Hearing Aid)

  • 정영숙;윤영호;박재훈;송병섭;이승하;김명남;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권5호
    • /
    • pp.487-495
    • /
    • 1998
  • 본 논문에서는 회로가 간단하고 체내에 삽입되는 부분이 영구자석만.:-로 이루어져있는 새로운 방식의 이식형 인공중이를 제안하였다. 트랜스듀서의 갭 조정이 필요없어 수술이 간편해지며, 코일을 외부로 보이지 않게 옷 내부에 둘 수 있어서 미용적인 측면에서도 우수하다. 제안된 이식형 인공중이의 성능을 측정하고 난청자의 청각 역치에 맞는 시스템을 설계하기 위하여 트랜스듀서를 통해 내이로 전달되는 힘을 정량적으로 해 석하였으며, 진동특성 실험을 통해서 이 해석의 타당성을 증명하였다. 또한 사람의 측두골을 이용하여 직접 침골(incus)의 진동변위를 측정하였다. 이 실험으로 제안된 시스템이 실제로 사람의 몸에 설치되었을 때 이소골(ossicles)을 충분히 진동시킬 수 있음을 증명하였다.

  • PDF

자가교정기법에 의한 유도초음파 모드전이에 관한 연구 (A Study on the Guided Wave Mode Conversion using Self-calibrating Technique)

  • 박정철;조윤호
    • 비파괴검사학회지
    • /
    • 제20권3호
    • /
    • pp.206-212
    • /
    • 2000
  • 유도초음파의 모드전이현상에 관한 연구가 박판구조물의 두께변화에 대한 비파괴평가를 위해 수행된다. 탐촉자와 시험체간의 접촉상태에 따른 불안정성을 제거하여 보다 신뢰도높은 방법으로 유도초음파실험결과를 얻을 수 있도록 하는 자가교정과정을 통해 반사와 전달계수의 비(R/T)가 측정된다. R/T에 관한 결과들은 구조물의 두께감소를 결정하는 데 사용될 수 있다. 실험측정값과 두께변화간의 의미있는 연관성을 도출하기 위해서는 자가교정 유도초음파검사에 입사모드뿐만 아니라 전이된 이종모드까지도 함께 고려되어야 함이 증명되었다. 이 연구를 통해, 정량적 비파괴검사기법으로서의 유도초음파검사기법의 가능성이 유도초음파 산란문제에 있어 자가교정과 다중모드전이를 함께 고려함으로써 검토되었다.

  • PDF

멀티빔 음향측심기의 기울임 시스템을 이용한 계측영역 확대 (Increasing Surveyed Area using Tilted Multi Beam Echo Sounder)

  • 박요섭;홍준표;공성규
    • 대한토목학회논문집
    • /
    • 제31권5D호
    • /
    • pp.739-747
    • /
    • 2011
  • 본 연구에서는 멀티빔 음향측심기 조사 각도의 물리적 한계 및 수면 및 수중의 장애물로 인하여 발생되는 음영 구역을 축소하고, 수직 구조물에 대한 계측 범위 확대를 위하여 트랜스듀서를 기울인 상태로 측량하는 기법을 적용하고 기술의 적정성을 평가하였다. 경남 마산 동호항에서 실시한 실해역 시험을 통해 트랜스듀서를 특정 각도($25^{\circ}$)로 기울여 측량한 결과, 기존 방식의 측심 결과와의 차이가 국제 수로측량 기준 상의 특등급 허용오차를 넘지 않았다. 총 조사대상 구역 $114,961m^2$의 수면적 중, 일반적인 조사방식으로는 $60,895m^2$로 53% 계측되었으나, 제안한 기울임 방식을 적용하여 $85,933m^2$를 계측할 수 있었다. 이는 전체 조사면적의 약 75%로, 동일조건의 장애물이 존재함에도 불구하고 기존 방식보다 약 22% 수평면적을 더 조사한 효과를 얻었다. 수직면에 대한 조사 대상구역 $7,421m^2$ 중, 일반적인 계측방식으로는 $1,046m^2$로 전체 조사면적의 약 14%가 조사되었으나, 제안한 기울임 방식으로 조사하여 총 $4,450m^2$, 대상면적의 60% 정도의 수직면이 계측되었다. 또한, 기울임 측량의 성능 평가를 위하여 선형 반사판을 고안하고, 측심기를 검교정하고, 트랜스듀서의 기울임 자체를 검교정하는 방안을 제시하였다.