• Title/Summary/Keyword: calibration of transducer

Search Result 67, Processing Time 0.022 seconds

Development of Calibration System for Contact Transducer (초음파 탐촉자의 교정 시스템 개발)

  • Nam, Y.H.;Seong, U.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.294-299
    • /
    • 1999
  • In this paper, the calibration system for contact transducer has been developed to improve the reliability of the inspection result of ultrasonic testing on rotors. This system consists of signal processing parts: (oscilloscope, spectrum analyzer, pulser/receiver), standard block, and user interface program. Signal processing for the calibration system was performed quickly with high accuracy. The developed system has been applied to a practical calibration of probe using the non-destructive testing on rotors, and demonstrated high sensitivity and precision.

  • PDF

Design of the Calibration System for Determining the Sensitivity of Ultrasonic Transducer (초음파 변환기의 감도 교정 시스템 구성)

  • 사공성대;조문재;최봉열
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.200-207
    • /
    • 1999
  • In this paper, a precise sensitivity measurement system of ultrasonic transducer in the frequency range from 1 MHz to 15 MHz, which can implement the reciprocity principle is constructed. All of the elements of this system such as the ultrasonic preamplifier, ultrasonic absorber, water tank, water degassing system, and four-axes translator and reflector are constructed. For the performance evaluation of the calibration system, a standard hydrophone precisely calibrated from PTB(Physikalisch Technische Bundesanstalt) in Germany are used. And the system parameters which affected the evaluation of the measurement accuracy and the reproducibility in various measuring conditions are considered. The measurement uncertainty of the calibration system is estimated within $\pm$ 2.0㏈.

  • PDF

Auto Calibration and Simulation Method for a Strain Gage Type Transducer/Signal Conditioner (스트레인 게이지형 센서 신호조정기 자동교정 및 시뮬레이션 기법)

  • 유제택
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1019-1025
    • /
    • 2003
  • We introduce a new auto-calibration/simulation method for a strain gage type transducer/signal-conditioner which guarantees the output linearity and compensates the error automatically. We design a micro voltage supply which is able to interface either AC or DC type excitation voltage. A new strain gage simulator is also designed. We make linearity output of the signal conditioner and can compensate error automatically with this new auto calibration/simulation method. The experimental results show that the error between the real value and the expected one is less than 1%.

Calibration of Acceleration Plant and Test Rig Design to Dynamic Fracture (동적 파괴에 대한 가속장치의 보정 및 시험장치 설계)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.47-52
    • /
    • 2008
  • The force transducer in the acceleration plant due to dynamic fracture is calibrated by dynamically using the stress pulses from a longitudinal bar. The bar is supported by two strings attached to the ceiling. The bar velocities before and after impact are measured and a full bridge at bar and transducer is formed by the four strain gauges. A transient recorder is used to store the stress pulse signals of force transducer and bar. For the first test series, three point bend test specimens can be chosen by means of test rig design and the inspection as sample experiment in this presented paper is sufficient for proving with the numerical simulation of the specimen model.

A Study on the Transducer Calibration for Acoustic Emission Measurement (AE 측정을 위한 탐촉자의 보정에 대한 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.53-58
    • /
    • 1996
  • In order to investigate the source mechanism of micro cracks through acoustic emission measurement induced by rock fracture, careful calibration of the entire linkage of the detecting system, from the transducers to transient recorder, is an essential requirement prior to testing. Transducers and digitiging system are generally the weakest links in the measurement system because they must translate mechanical motions into digital electric signals. In this study, PAC piezoelectric pressure transducers are calibrated with a standard NBS conical shaped displacement transducer and a DG piezoelectric displacement transducer. The NBS and PAC transducers are insensitive to changes in horizontal impingement angle but sensitive to changes in incident angle. The ray path along the logitudinal axis of the tranducer produced a maximum response while the ray path perpendicular to the transducer axis gave a minimum. And a difference in individual transducers factor for a peak-to-peak amplitude of PAC transducers was within 40%. An average PAC transducer coefficient was determined as 77mv/pm by an absolute calibration test using NBS transducer.

  • PDF

An Automatic Calibration Technique for Piezoelectric Pressure Transducers (압전형 압력센서의 교정기법 자동화)

  • 홍성수;최주호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.1012-1016
    • /
    • 1996
  • This paper presents an automatic calibration technique for piezoelectic low pressure transducer, which is useful to measure a pressure within 500 psi. This system with automatic calibration function and error correction algorithm generates standard dynamic pressure for the calibration of sensor. With the compensation for the offset voltage and the pressure error, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

An automatic calibration technique for piezoelectric pressure transducers (압전형 압력센서의 교정기법 자동화)

  • Hong, Sung-Soo;Choi, Ju-Ho;Yoo, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1368-1371
    • /
    • 1996
  • This paper presents an automatic calibration technique for piezoelectric low pressure transducer, which is useful to measure a pressure within 500 psi. This system with automatic calibration function and error correction algorithm generates standard dynamic pressure for the calibration of sensor. With the compensation for the offset voltage and the pressure error, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

An automatic calibration technique for piezoelectric pressure sensors (압전형 압력센서의 교정기법 자동화)

  • Choi, Ju-Ho;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.4
    • /
    • pp.357-362
    • /
    • 1997
  • This paper suggests an automatic calibration technique for piezoelectric low pressure transducer measuring a pressure blow 500psi. The present calibration system embedded with error correction algorithm generates it's best you don't cut parts of wards like so dynamic pressure and compensates offset voltage and pressure error. It is shown via experimental results that the instrumentation accuracy has been improved and mean time between calibrations has been shortened.

  • PDF

A Pulse-Echo Testing Model for Partially Damaged Ultrasonic Transducers (부분 손상을 입은 초음파 탐촉자의 펄스-에코 시험 모델)

  • Song, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.2
    • /
    • pp.95-108
    • /
    • 1996
  • In ultrasonic testing, flaw signal from which quantitative information on flaws is determined is influenced by 3 factors : (1) the incident wavefield.produced by the transducer, (2) the scattered waves produced by flaws, and (3) the reception of the scattered waves back at the transducer. So even small changes in transducer performance due to aging or unexpected damages can produce the changes in the characteristics of flaw signal and finally the changes in the quantitative information on flaws. Thus a reliable calibration method of transducer performance is desired. Recently, theoretical models for ultrasonic testing have been employed as reference standards for the calibration of transducers which are considered as circular planar piston sources in the most of cases. But this simplification cannot be applied to partially damaged transducer which has lost their symmetry in performance, even not in appearance. Unfortunately there has been no reliable practical model which can be used for the calibration of partially damaged transducers. Here a pulse-echo testing model for partially damaged ultrasonic transducers was developed with experimental verification. The experimental responses agree very well with the theoretical prediction. So we expect that this model can be served as a theoretical reference standards for transducer calibration.

  • PDF