• Title/Summary/Keyword: calibration errors

Search Result 448, Processing Time 0.026 seconds

Calibation and Compensation for the Kinematic Error in Robot Manipulatior (로봇의 기구학적 오차측정과 보상에 관한 연구)

  • 이종신;임성호;조희상;이의훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.545-549
    • /
    • 1993
  • This paper presents the method of calibrating and compensating for the kinematic errors in robot manipulators. A calibration model is developed to represent any geometric errors in the manipulator's structure. A calibration jig is used to find the values of these kinematic errors in the end-effector's position and a calibration algormined for a SSR-6 robot manipulator developed by Samsung Heavy Industry, Daeduk R & D Center. Through this experiment the maximun kinematic error is reduced from 10mm to 0.4mm

  • PDF

Calibration/Compensation of Errors of the Touch Probe (접촉식 프로브의 오차교정 및 보정기술)

  • 박희재;이교일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2081-2087
    • /
    • 1994
  • Touch trigger probes are widely used for inspection purposed in the CMM(Coordinate meauring machine) or machine tool. The errors introduced by measurement probe are fairy systematic, thus can be calibrated and compensated properly. This paper presents a technique for the error calibration and compensation of the probe errors, which can be easily applicable to the manufacturers and users of the measurement probe. The probe coordinate system is defined for the probe error assessment, and a reference sphere ball is measured, and the probe errors are calibrated. The calibrated probe errors are represented in the 3D error map and 2D error map along probing direction. Detail algorithms for the error compensation are proposed.

Study on the Error Compensation in Strain Measurement of Sheet Metal Forming (박판성형 변형률 측정 오차보정에 관한 연구)

  • 한병엽;차지혜;금영탁
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.270-273
    • /
    • 2003
  • The strain measurement of the panel in the sheet metal forming is essential work which provides experimental data needed to die design, process design, and product inspection. To measure efficiently the complex geometry strain, the 3-dimensional automative strain measurement system, which has high accuracy in theory, but has some 3∼5% errors in practice, is often used. The object of this study is to develop the error compensation technology to eliminate the strain, errors resulted when formed panels are measured using an automated strain measurement system. To achieve the study object, the position error calibration method correcting coordinates of the grid node recognized by a camera using error functions is suggested. Then the position errors were found by calculating the difference in the position of the cube node between real coordinates and measured coordinates in toms of node coordinates and the error calibration equations were derived by regressing the position errors. In order to show the validation of the suggested position error calibration method, finite element analysis and current calibration method was performed for the initial-blankformed.

  • PDF

Self-calibration Algorithm of Systematic Errors For Interferometer (간섭계에 있어서의 계통 오차의 자율 교정 알고리즘)

  • Ikumatsu Fujimoto;Lee Taeyong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.63-71
    • /
    • 2005
  • When an almost flat surface under test is measured by an interferometer, the measurement result is largely influenced by systematic errors that include geometrical errors of a reference flat surface. To determine the systematic errors of the interferometer by the conventional method that is called the three flat method, we must take the reference flat surface out from the interferometer and measure it. Because of difficulties to set the reference flat surface to the interferometer exactly and quickly, this method is not practical. On the other hand, the method that measures a surface under test with some shifts in the direction being perpendicular to the optical axis of the interferometer is studied. However, the parasitic pitching, rolling and up-down movement caused by the above shifts brings serious error to the measurement result, and the algorithm by which the influences can be eliminated is not still established. In this paper, we propose the self-calibration algorithm for determining the systematic errors that include geometrical errors of a reference flat surface by several rotation shifts and a linear shift of general surface under test, and verify by a numerical experiment that this algorithm is useful for determining the systematic errors.

Resistivity and Calibration Error Estimations for Small-Loop Electromagnetic Method

  • Sasaki, Yutaka;Son, Jeong-Sul;Kim, Chang-Ryol;Kim, Jung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.167-172
    • /
    • 2007
  • The frequency-domain small-loop electromagnetic (EM) instruments are increasingly used for shallow environmental and geotechnical surveys because of their portability and speed. However, it is well known that the data quality is generally so poor that quantitative interpretation of the data is not justified in many cases. We present an inversion method that allows the correction for the calibration errors and also constructs multidimensional resistivity models. The key point in this method is that the data are collected at least at two different heights. The forward modeling used in the inversion is based on an efficient 3-D finite-difference method, and its solution was checked against 2-D finite-element solution. The synthetic and real data examples demonstrate that the joint inversion recovers reliable resistivity models from multi-frequency data severely contaminated by the calibration errors.

  • PDF

Non-Linearity Error Detection and Calibration Method for Binary-Weighted Charge Redistribution Digital-to-Analog Converter (이진가중치 전하 재분배 디지털-아날로그 변환기의 비선형 오차 감지 및 보상 방법)

  • Park, Kyeong-Han;Kim, Hyung-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.420-423
    • /
    • 2015
  • This paper proposes a method of non-linearity error detection and calibration for binary-weighted charge-driven DACs. In general, the non-linearity errors of DACs often occur due to the mismatch of layout designs or process variation, even when careful layout design methods and process calibration are adopted. Since such errors can substantially degrade the SNDR performance of DAC, it is crucial to accurately measure the errors and calibrate the design mismatches. The proposed method employs 2 identical DAC circuits. The 2 DACs are sweeped, respectively, by using 2 digital input counters with a fixed difference. A comparator identifies any non-linearity errors larger than an acceptable discrepancy. We also propose a calibration method that can fine-tune the DAC's capacitor sizes iteratively until the comparator finds no further errors. Simulations are presented, which show that the proposed method is effective to detect the non-linearity errors and calibrate the capacitor mismatches of a 12-bit DAC design of binary-weighted charge-driven structure.

  • PDF

Development and Application of Three-axis Motion Rate Table for Efficient Calibration of Accelerometer and Gyroscope (효율적인 각/가속도 센서 오차 보상을 위한 3 축 각도 측정 장치의 개발 및 활용)

  • Kwak, Hwan-Joo;Hwang, Jung-Moon;Kim, Jung-Han;Park, Gwi-Tae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.7
    • /
    • pp.632-637
    • /
    • 2012
  • This paper introduces a simple and efficient calibration method for three-axis accelerometers and three-axis gyroscopes using three-axis motion rate table. Usually, the performance of low cost MEMS-based inertial sensors is affected by scale and bias errors significantly. The calibration of these errors is a bothersome problem, but the previous calibration methods cannot propose simple and efficient method to calibrate the errors of three-axis inertial sensors. This paper introduces a new simple and efficient method for the calibration of accelerometer and gyroscope. By using a three-axis motion rate table, this method can calibrate the accelerometer and gyroscope simultaneously and simply. Experimental results confirm the performance of the proposed method.

Errors in Recorded Information and Calibration of a Catchment Modelling System(II) - Monitoring Calibration Approach - (기록치 오차와 유역모형의 검정(II) - 모니터링 검정방법 -)

  • Choi, Kyung Sook
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.117-125
    • /
    • 2003
  • Since the recorded information used for operation of a catchment modelling system contain errors that influence the calibration of catchment modelling system control parameter values, the accurate estimation of these parameters is difficult. Despite these influences, existing traditional calibration approaches focus only on achieving the best "curve fitting" between simulated and recorded data, and not on generic evaluation of control parameter values. This paper introduces an Early Stopping Technique which is aimed at avoiding the procedure of curve-fitting through monitoring improvements in the objective function used for assessing the optimal parameter set. Application of this approach to the calibration of SWMM (Storm Water Management Model) on the Centennial Park catchment in Sydney, Australia is outlined. outlined.

Measurement of local wall temperature and heat flux using the two-thermocouple method for a heat transfer tube

  • Ahn, Taehwan;Kang, Jinhoon;Jeong, Jae Jun;Yun, Byongjo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1853-1859
    • /
    • 2019
  • The two-thermocouple method was investigated experimentally to evaluate its accuracy for the measurement of local wall temperature and heat flux on a heat transfer tube with an electric heater rod installed in an annulus channel. This work revealed that a thermocouple flush-mounted in a surface groove serves as a good reference method for the accurate measurement of the wall temperature, whereas two thermocouples installed at different depths in the tube wall yield large bias errors in the calculation of local heat flux and wall temperature. These errors result from conductive and convective changes due to the fin effect of the thermocouple sheath. To eliminate the bias errors, we proposed a calibration method based on both the local heat flux and Reynolds number of the cooling water. The calibration method was validated with the measurement of local heat flux and wall temperature against experimental data obtained for single-phase convection and two-phase condensation flows inside the tube. In the manuscript, Section 1 introduces the importance of local heat flux and wall temperature measurement, Section 2 explains the experimental setup, and Section 3 provides the measured data, causes of measurement errors, and the developed calibration method.

Measurement Errors of Non-contact Type Vibration Sensors Used for Precision Measurement of Shaft Vibration (정밀 축진동 측정에 사용되는 비접촉식 진동센서의 측정오차)

  • 전오성;김동혁;최병천
    • Journal of KSNVE
    • /
    • v.1 no.2
    • /
    • pp.107-113
    • /
    • 1991
  • When non-contact type vibration probes are used for the precision measurement of shaft vibration, they can induce the measurement errors due to the shaft curvature since they have been calibrated for the flat plate. In this study the errors due to the shaft radius and the misalignment between the shaft and probe centerlines are analyzed, and an in-situ calibration tool, which can be conveniently used for calibration independent of the shaft curvature and material, is introduced.

  • PDF