• 제목/요약/키워드: calibration equation

검색결과 312건 처리시간 0.029초

CALIBRATION OF STELLAR PARAMETERS OF 85 PEG SYSTEM

  • Bach, Kiehunn;Kim, Yong-Cheol;Demarque, Pierre
    • Journal of Astronomy and Space Sciences
    • /
    • 제24권1호
    • /
    • pp.31-38
    • /
    • 2007
  • We have investigated the evolutionary status of 85 Peg within the framework of standard evolutionary theory. 85 Peg has been known to be a visual and spectroscopic binary system in the solar neighborhood. In spite of the accurate information of the total mass (${\sim}1.5M_{\odot}$) and the distance (${\sim}12pc$) from the HIPPARCOS parallax, it has been undetermined an individual mass, therefore the evolved status of the system. Moreover, the coupled uncertainties of chemical composition and age, make matters worse in predicting an evolutionary status of the system. Nevertheless, we computed the various possible models for 85 Peg, and then calibrated stellar parameters by adjusting to the recent observational data. Our modelling computation has included recently updated input physics and stellar theory such as opacity, equation of state, and chemical diffusion. Through a statistical assessment, we have derived a confident parameter set as the best solution which minimized $X^{2}$ within the observational error domain. Most of all, we found that 85 Peg is not a binary system but a triple system with an unseen companion 85 Peg $B_{b}\;{\sim}0.16M_{\odot}$. The aim of the present paper is (1) to provide a complete modelling of the stellar system based on the evolutionary theory, and (2) to constrain the physical dimensions such as mass, metallicity and age.

PTT를 이용한 자전거 운동 중 지속적인 혈압의 예측 (Continuous Blood Pressure Prediction Using PTT During Exercise)

  • 김철승;문기욱;권정훈;엄광문
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.370-375
    • /
    • 2006
  • The purpose of this work is to predict the systolic blood pressure (BP) during exercise from pulse transit time (PTT) for warning of possible danger. PTT was calculated as the time between R-peak of ECG and the peak of differential photoplethysmograph (PPG). For the PTT-BP model, we used regress equations from previous studies and 3 kinds of new models combining linear and nonlinear regress equation. The model parameters were estimated with the data measured under low to middle intensity exercise, and then was tested with the data measured under high intensity exercise. Predicted BP values after high intensity exercise were compared with those measured by cuff-type sphygmomanometer. The results showed that the error between measured and predicted values were acceptable for the monitoring BP. We tested PTT-BP models 1 month after the identification without further calibration. Models could predict the BP and the errors between measured and predicted BP were about 5mmHg. The suggested system is expected to be helpful in recognizing any danger during exercise.

Method of Identifying Dynamic Multileaf Collimator Irradiation that is Highly Sensitive to a Systematic MLC Calibration Error

  • Zygmanski, P.;Kung, J.H.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.74-82
    • /
    • 2002
  • In Intensity Modulated Radiotherapy (IMRT), radiation is delivered in a multiple of Multileaf Collimator (MLC) subfields. A subfield with a small leaf-to-leaf opening is highly sensitive to a leaf-positional error. We introduce a method of identifying and rejecting IMRT plans that are highly sensitive to a systematic MLC gap error (sensitivity to possible random leaf-positional errors is not addressed here). There are two sources of a systematic MLC gap error: Centerline Mechanical Offset (CMO) and, in the case of a rounded end MLC, Radiation Field Offset (RFO). In IMRT planning system, using an incorrect value of RFO introduces a systematic error ΔRFO that results in all leaf-to-leaf gaps that are either too large or too small by (2ㆍΔRFO), whereas assuming that CMO is zero introduces systematic error ΔCMO that results in all gaps that are too large by ΔCMO = CMO. We introduce a concept of the Average Leaf Pair Opening (ALPO) that can be calculated from a dynamic MLC delivery file. We derive an analytic formula for a fractional average fluence error resulting from a systematic gap error of Δ$\chi$ and show that it is inversely proportional to ALPO; explicitly it is equal to, (equation omitted) in which $\varepsilon$ is generally of the order of 1 mm and Δx=2ㆍΔRFO+CMO. This analytic relationship is verified with independent numerical calculations.

  • PDF

로봇 착유기를 위한 3차원 위치정보획득 시스템 (3D Image Processing System for an Robotic Milking System)

  • 김웅;권두중;서광욱;이대원
    • 한국축산시설환경학회지
    • /
    • 제8권3호
    • /
    • pp.165-170
    • /
    • 2002
  • This study was carried out to measure the 3D-distance of a cow model teat for an application possibility on Robotic Milking System(RMS). A teat recognition algorithm was made to find 3D-distance of the model by using Gonzalrez's theory. Some of the results are as follows. 1 . In the distance measurement experiment on the test board, as the measured length, and the length between the center of image surface and the measured image point became longer, their error values increased. 2. The model teat was installed and measured the error value at the random position. The error value of X and Y coordinates was less than 5㎜, and that of Z coordinates was less than 20㎜. The error value increased as the distance of camera's increased. 3. The equation for distance information acquirement was satisfied with obtaining accurate distance that was necessary for a milking robot to trace teats, A teat recognition algorithm was recognized well four model cow teats. It's processing time was about 1 second. It appeared that a teat recognition algorithm could be used to determine the 3D-distance of the cow teat to develop a RMS.

  • PDF

SOLAR SHORT-PERIOD OSCILLATIONS EXCITED BY A SMOOTH FORCE

  • CHANG HEON-YOUNG
    • 천문학회지
    • /
    • 제36권2호
    • /
    • pp.67-72
    • /
    • 2003
  • The basic objective of helioseismology is to determine the structure and the dynamics of the Sun by analysing the frequency spectrum of the solar oscillations. Accurate frequency measurements provide information that enables us to probe the solar interior structure and the dynamics. Therefore the frequency of the solar oscillation is the most fundamental and important information to be extracted from the solar oscillation observation. This is why many efforts have been put into the development of accurate data analysis techniques, as well as observational efforts. To test one's data analysis method, a realistic artificial data set is essential because the newly suggested method is calibrated with a set of artificial data with predetermined parameters. Therefore, unless test data sets reflect the real solar oscillation data correctly, such a calibration is likely incomplete and a unwanted systematic bias may result in. Unfortunately, however, commonly used artificial data generation algorithms insufficiently accommodate physical properties of the stochastic excitation mechanism. One of reason for this is that it is computaionally very expensive to solve the governing equation directly. In this paper we discuss the nature of solar oscillation excitation and suggest an efficient algorithm to generate the artificial solar oscillation data. We also briefly discuss how the results of this work can be applied in the future studies.

Milk Fat Analysis by Fiber-optic Spectroscopy

  • Ohtani, S.;Wang, T.;Nishimura, K.;Irie, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.580-583
    • /
    • 2005
  • We have evaluated the application of spectroscopy using an insertion-type fiber-optic probe and a sensor at wavelengths from 400 to 1,100 nm to the measurement of milk fat content on dairy farms. The internal reflectance ratios of 183 milk samples were determined with a fiber-optic spectrophotometer at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$. Partial least squares (PLS) regression was used to develop calibration models for the milk fat. The best accuracy of determination was found for an equation that was obtained using smoothed internal reflectance data and three PLS factors at 20$^{\circ}C$. The correlation coefficients between predicted and reference milk fat at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$ were r=0.753, r=0.796 and r=0.783, respectively. The predictive explained variances ($Q^2$) of the final model, moreover, were more than 0.550 at all temperatures, and the regression coefficients of determination ($R^2$) were more than 0.6 (60%). Our results indicate that milk has different internal reflectance measured in the range of visible and near infrared wavelengths (400 to 1,100 nm), depending on its fat content.

Radar Backscattering Measurements of Paddy Rice Field using L, C, and X-band Polarimetric Scatterometer

  • Kim, Yi-Hyun;Hong, Suk-Young;Park, Ji-Sung;Lee, Eun-Sun;Lee, Hoon-Yol
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.633-636
    • /
    • 2007
  • The objective of this study is to measure backscattering coefficients of paddy rice using L, C, X-bands scatterometer system during a rice growth period. The measurement was conducted at an experimental field located in National Institute of Agricultural Science and Technology (NIAST), Suwon, Korea. The rice cultivar was a kind of Japonica type, called Chuchung. The scatterometer system consists of dual-polarimetric square horn antennas, HP8720D vector network analyzer (20MHz ${\sim}$ 20GHz), RF cables, and a personal computer that controls frequency, polarization and data storage. The scatterometer system is calibrated using a calibration kit (3.5mm, 85052D). The backscattering coefficients were calculated by applying radar equation for the measured at incidence angles between $20^{\circ}$ and $60^{\circ}$ for four polarization (HR, VV, HV, VH), respectively, and compared with rice growth data such as plant height, stem number, biomass, dry weight and LAI that were collected at time of each scatterometer measurement simultaneously.

  • PDF

Retrieval of surface parameters in tidal flats using radar backscattering model and multi-frequency SAR data

  • Choe, Byung-Hun;Kim, Duk-Jin
    • 대한원격탐사학회지
    • /
    • 제27권3호
    • /
    • pp.225-234
    • /
    • 2011
  • This study proposes an inversion algorithm to extract the surface parameters, such as surface roughness and soil moisture contents, using multi-frequency SAR data. The study areas include the tidal flats of Jebu Island and the reclaimed lands of Hwaong district on the western coasts of the Korean peninsula. SAR data of three frequencies were accordingly calibrated to provide precise backscattering coefficients through absolute radiometric calibration. The root mean square (RMS) height and the correlation length, which can describe the surface roughness, were extracted from the backscattering coefficients using the inversion of the Integral Equation Method (IEM). The IEM model was appropriately modified to accommodate the environmental conditions of tidal flats. Volumetric soil moisture was also simultaneously extracted from the dielectric constant using the empirical model, which define the relations between volumetric soil moistures and dielectric constants. The results obtained from the proposed algorithm were verified with the in-situ measurements, and we confirmed that multi-frequency SAR observations combined with the surface scattering model for tidal flats can be used to quantitatively retrieve the geophysical surface parameters in tidal flats.

열피로 균열성장시험을 위한 ESET 시편의 확장된 컴플라이언스 해 (Extended Compliance Solution of ESET Specimen for Thermal fatigue Crack Growth Test)

  • 이호진;김만원;이봉상
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.62-67
    • /
    • 2005
  • An eccentrically-loaded single edge crack tension specimen (ESET) is similar to a compact tension(CT) specimen loaded in tension-tension. The standard ESET specimen exhibits advantages over other types of cracked specimen, such as n, single-edge crack, and middle-crack tension specimen. The details of ESET specimen configuration, test procedure, and calculations are described in ASTM E647 standard. However, a difficulty in attaching COD gage to the knife-edge on the front foe of the specimen can be found when the size of ESET specimen is small for rapid cooling and heating in thermal fatigue testing. The finite element analysis is performed for the ESET specimen with projected knife-edge on the front foe and a crack-length-compliance equation is suggested for the new specimen configuration. Calibration test are conducted with 347 stainless steel to compare the measured crack length with the calculated crack length from the suggested compliance expression. The test results showed good agreements with those of analysis.

해안연약 지반 조사를 위한 4전극 전기비저항 프로브 (4 Electrical Resistivity Probe for Investigating soft offshore soils)

  • 김준한;윤형구;배명호;정순혁;이종섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.464-475
    • /
    • 2009
  • Electrical resistivity can be used for porosity estimation. In order to improve previously developed ERCP(Electrical Resistivity Cone Probe), 4ERP(4 Electrical Resistivity Probe), which has Wenner array at the tip of probes, has been developed. In properties of current flow Wenner array measures electrical properties of undisturbed area during penetration and relatively correct measurements are guaranteed without polarization. Furthermore, Wenner array equation can estimate electrical resistivity without extra calibration. 4ERP is developed into 2 types, penetration and fixation. Penetration type has wedge-shaped tip. Considering disturbance minimization, fixed type has plane tip. Fixed type 4ERP in consolidation cell measure electrical resistivity increment along porosity decrease, and penetration type 4ERP measured resistivity profile along the depth in chamber. Applying Archie's law, porosity profile was estimated with electrical resistivity. The tests result suggests that 4ERP can be new site investigation equipment with little disturbance.

  • PDF