• Title/Summary/Keyword: calibration equation

Search Result 312, Processing Time 0.035 seconds

DEVELOPMENT OF A REAL-TIME FLOOD FORECASTING SYSTEM BY HYDRAULIC FLOOD ROUTING

  • Lee, Joo-Heon;Lee, Do-Hun;Jeong, Sang-Man;Lee, Eun-Tae
    • Water Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.113-121
    • /
    • 2001
  • The objective of this study is to develop a prediction mode for a flood forecasting system in the downstream of the Nakdong river basin. Ranging from the gauging station at Jindong to the Nakdong estuary barrage, the hydraulic flood routing model(DWOPER) based on the Saint Venant equation was calibrated by comparing the calculated river stage with the observed river stages using four different flood events recorded. The upstream boundary condition was specified by the measured river stage data at Jindong station and the downstream boundary condition was given according to the tide level data observed at he Nakdong estuary barrage. The lateral inflow from tributaries were estimated by the rainfall-runoff model. In the calibration process, the optimum roughness coefficients for proper functions of channel reach and discharge were determined by minimizing the sum of the differences between the observed and the computed stage. In addition, the forecasting lead time on the basis of each gauging station was determined by a numerical simulation technique. Also, we suggested a model structure for a real-time flood forecasting system and tested it on the basis of past flood events. The testing results of the developed system showed close agreement between the forecasted and observed stages. Therefore, it is expected that the flood forecasting system we developed can improve the accuracy of flood forecasting on the Nakdong river.

  • PDF

Indoor Emission Characteristics of Liquid Household Products using Purge - and - Trap Method

  • Kwon, Ki-Dong;Jo, Wan-Kuen
    • Environmental Engineering Research
    • /
    • v.12 no.5
    • /
    • pp.203-210
    • /
    • 2007
  • Since the emissions composition from the household products have potentially been associated with health risks for building occupants, the chemical composition emitted from the products should be surveyed. The current study identified the emission composition for 42 liquid household products, using a purge-and-trap method. This evaluation was done by classifying the household products into five product classes (deodorizers, household cleaners, color removers, pesticides, and polishes). Nineteen compounds were chosen on the basis of selection criteria. The quality control program for purge-and-trap and analytical systems included tests of laboratory blank Tenax traps and blank water samples, and the determination of calibration equation, measurement precision, method detection limit (MDL), and recovery. The number of chemicals varied according to the product categories, ranging from 4 for the product category of bleaches to 12 for the product categories of air fresheners and nail color removers. For all product categories, the emission composition and concentrations varied broadly according to product. It is noteworthy that most household products emit limonene: 19 of 25 cleaning products; 5 of 6 deodorizers; 1 of 3 pesticides; 3 of 3 color removers; and 4 of 5 polishes. It was suggested that the use of household products sold in Korea could elevate the formation of secondary toxic pollutants in indoor environments, by the reaction of limonene with ozone, which entered indoor environments or might be generated by indoor sources such as electronic air cleaning devices and copying machines.

Radiation exposure dose in human blood lymphocytes as assessed by the CBMN assay

  • Ryu, Tae Ho;Kim, Jin-Hong;Kim, Jin Kyu
    • Journal of Ecology and Environment
    • /
    • v.37 no.4
    • /
    • pp.195-200
    • /
    • 2014
  • The chances of accidental exposure are augmented as the application of ionizing radiation increases in various fields. Such accidental exposures may occur at nuclear power plants, laboratories, and hospitals. Cytogenetic assays have been used for estimating radiation dose in the situation of the accidents. The micronucleus assay has several advantages over the other cytogenetic methods as it is simple and fast. The present study aimed at investigation of the micronuclei frequencies in cytokinesis-block cells in human blood lymphocytes after ${\gamma}$-irradiation and at establishment of a standard dose response relationship. The samples of peripheral blood were obtained from 6 different donors aged between 24 and 30 years old. The bloods were irradiated in vitro with 0-5 Gy. A linear quadratic dose-response equation was obtained by scoring the micronuclei in binucleated cells; $y=27.87x^2+46.13x+2.08$ ($r^2=0.99$). Irradiation caused a significant decrease in the nuclear division index. Necrotic and apoptotic cells increased in number after irradiation in a dose-dependent manner. In conclusion, the conventional cytokinesis-block micronucleus assay has proven to be the great technique in biological dosimetry. Dose-response calibration curve derived from CMBN assay could be used to estimate the exposure dose during a radiological emergency.

Design and Fabrication of an Electromagnetic Flowmeter (전자기유량계의 설계 및 제작)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

Kinetics of Oil-Proof Agent Adsorption onto Cellulose Fibers

  • Zhu, Hongxiang;Honghu, Zeng;Wang, Shuangfei;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.5
    • /
    • pp.59-65
    • /
    • 2009
  • Adsorption of an oil-proof agent (OPA)onto cellulose fibers during the papermaking process was investigated using UV-Vis spectrophotometry by measuring the OPA concentration decrease in the solution. From the calibration curve, the spectrum were converted to chemical concentrations in solution, from which the amount adsorbed onto the fiber surface could be determined. Thus, it was possible to determine the total amount adsorbed onto the fibers and in solution. Using this approach, we studied the adsorption behavior of the OPA onto the fiber surface and derived its, ${\Gamma}^s_t={\Gamma}^s_{\infty}(1-e^{-k_{\alpha}t})$. The values of the parameters kaand ${\Gamma}^s_{\infty}$ were determined using a mathematic model based on a mass transfer equation. Ultimately, a complete was derived: $Q={\alpha}{\cdot}\sum\limits_{i-1}^m{\pi}d_il_i{\cdot}M_A{\cdot}(1-e^{-k_{\alpha}t})/A_N$.

Tip Position Control of a Robot Manipulator using Visual Markers (영상표식 기반의 로봇 매니퓰레이터 끝점 위치 제어)

  • Lim, Sei-Jun;Lim, Hyun;Lee, Young-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.883-890
    • /
    • 2010
  • This paper proposes tip position control system which uses a visual marker to determine the tip position of a robot manipulator. The main idea of this paper is to introduce visual marker for the tracking control of a robot manipulator. Existing researches utilize stationary markers to get pattern information from them. Unlike existing researches, we introduce visual markers to get the coordinates of them in addition to their pattern information. Markers need not be stationary and the extracted coordinate of markers are used as a reference trajectory for the tracking control of a robot manipulator. To build the proposed control scheme, we first obtain intrinsic parameters through camera calibration and evaluate their validity. Secondly, we present a procedure to obtain the relative coordinate of a visual marker with respect to a camera. Thirdly, we derive the equation for the kinematics of the SCORBOTER 4pc manipulator which we use for control of manipulator. Also, we provide a flow diagram of entire visual marker tracking system. The feasibility of the proposed scheme will be demonstrated through real experiments.

VARIOUS NIR SAMPLE PRESENTATIONS FOR AGRICULTURAL PRODUCTS SUCH AS INTACT FRUITS, SINGLE GRAINS, VEGETABLE JUICE, MILK AND THE OTHERS

  • Kawano, Sumio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1021-1021
    • /
    • 2001
  • Sample presentation, which means how to set samples to an NIR instrument, is very important in Near Infrared (NIR) Spectroscopy. When sample presentation is not suitable for the samples that you use, very good spectra can not be obtained even if you use a sophisticated NIR instrument. In my presentation, various NIR sample presentations for agricultural products such as intact fruits, single grains, vegetable juice and the others will be explained. In case of peaches with thin peel, the fiber optics of Interactance can be used. However, the fiber optics are not suitable for oranges with relatively thick peel. In this case, transmittance method is useful. As for a small sample such as single grains, a specially designed cell is needed. The cell in transmittance mode has been developed and then applied to single kernels of rice and soybean. In this case we also used the fiber optics. As regards liquid type of sample, a cuvette cell made of quartz in transmittance mode is popular. However, it is time-consuming to wash and dry it. In order to compensate this disadvantage the sample presentation using normal test tubes as sample cells have been developed and applied to milk, rumen juice and urine of a milking cow. An individual test tube can be used for each sample if you use the calibration equation with sample cell compensation. The test tube cell has also been applied to spinach juice for determination of undesirable constituents. It is concluded that sample presentation is most important for NIR Spectroscopy.

  • PDF

PRELIMINARY STUDY ON NIR SPECTRA OF RETROGRADED STARCH

  • Terazawa, Yoko;Maekawa, Takaaki;Kawano, Sumio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1515-1515
    • /
    • 2001
  • Retrogradation of starch is one of important quality indexes for food based on starch such as rice. Therefore, in this research, possibility of near infrared spectroscopy to determine the degree of the retrogradation was examined. The degree of the retrogradation was indicated as the degree of geratinization analyzed by BAP(-amylase-pullulanase) method. 20 samples which have a wide range of the degree of the retrogradation were prepared and the NIR spectra of the samples were measured in reflectance mode with the NIR Systems 6500. In the correlation plots calculated from the 2nd derivative values of the MSC treated spectra and the degree of the geratinization, the major negative peaks of 1544 nm and 2258 nm, and the major positive peaks of 1460 nm, 1602 nm, 1766 nm and 2136 nm could be observed, indicating that NIR absorption at the positive peak wavelengths became strong while the absorption at the negative peak wavelengths became weak as the degree of the retrogradation increased. Because there is negative correlation between the degree of the retrogradation and the degree of the geratinization. As a result of MLR using the 2nd derivative values of the MSC treated spectra and the degree of the geratinization, good calibration equation which include 2258 nm as the first wavelength and 1764 nm as the second one could be obtained, indicating that NIR spectroscopy has a possibility to detect the retrogradation of starch. In order to find the assignment of the bands observed in the correlation plots, further study may be needed.

  • PDF

Distribution of Excess Porepressure caused by PCPT into OC clay

  • Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.312-333
    • /
    • 2006
  • This paper presents the results of an analysis of the excess porewater pressure distribution due to piezocone penetration in overconsolidated clays. From piezocone test results for moderately and heavily overconsolidated clays, it was observed that the excess porewater pressure increases monotonically from the piezocone surface to the outer boundary of the shear zone and then decreases logarithmically to the outer boundary of the plastic zone. It was also found that the size of the shear zone decreases from approximately 2.2 to 1.5 times the cone radius with increasing OCR, while the plastic radius is about 11 times the piezocone radius, regardless of the OCR. The equation developed in this study based on the modified Cam clay model and the cylindrical cavity expansion theory, which take into consideration the effects of the strain rate and stress anisotropy, provide a good prediction of the initial porewater pressure at the piezocone location. The method of predicting the spatial distribution of excess porewater pressure proposed in this study is based on a linearly increasing ${\Delta}u_{shear}$. In the shear zone and a logarithmically decreasing ${\Delta}u_{oct}$, and is verified by comparing with the excess porewater pressure measured in overconsolidated specimens at the calibration chamber.

  • PDF

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF