• Title/Summary/Keyword: calibration chart

Search Result 26, Processing Time 0.031 seconds

Color Calibration Method for Improvement of Reliability on Image Analysis of Rock (암석영상분석의 신뢰도 향상을 위한 컬러보정기법 연구)

  • 장윤섭;박형동
    • Tunnel and Underground Space
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • Recently, the use of image analysis methods and commercial equipments has been extensively increased in the field of rock engineering. However the problem of errors involved in the image acquisition and subsequent analysis procedure has been frequently neglected. In addition there has been few studies dealing with this problem. So proper color calibration method is needed to be developed for the objectivity and improvement of reliability on image analysis of rock. Color calibration method using standard color rendition chart was adopted on this study. Color calibration and error analysis were carried out for the image acquired from granite rock samples. As a result, comparison among other rock images and improvement of reliability on whole analysis were possible.

Study on the calibration of a five-hole Pitot-tube for the wake measurement (반류 계측용 5공 피토관의 캘리브레이션 방법에 관한 연구)

  • Kim, W.J.;Kim, D.H.;Yoon, H.S.;Moon, D.Y.;Van, S.H.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.2
    • /
    • pp.11-19
    • /
    • 1997
  • The new definition of calibration coefficients is proposed for a five-hole Pitot tube. Two-angle chart calibration other than one-angle variation is considered to improve the accuracy in the measurement of the three-dimensional velocity fields. Several sets of correlation coefficients are introduced for different shapes of the probe tip. The calibration method with one-angle variation is compared with the new two-angle chart calibration method and the improvement of the present method is clearly shown.

  • PDF

Response Calibration for Bridges based on Statistical Quality Control Chart (통계적 품질 관리도에 기초한 교량의 응답 보정)

  • Hwang, Jin Ha;An, Seoung Su;Kim, Ju Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.61-70
    • /
    • 2013
  • This paper presents the response calibration method based on quality control range, which is established from the concept and method of statistical quality control for natural frequency ratio and response ratio. To this end, statistical analysis including descriptive statistics analysis, normality test, ANOVA were performed for response characteristics obtained from loading tests and structural analysis for more than hundred and thirty well-conditioned bridges. Suggested method is based on real structural integrity evaluation case studies and statistical quality control approach, in this respect it is expected to provide scientific criteria and systematic procedure for response calibration and load carrying capacity assessment.

Comparison of Multivariate CUSUM Charts Based on Identification Accuracy for Spatio-temporal Surveillance (시공간 탐지 정확성을 고려한 다변량 누적합 관리도의 비교)

  • Lee, Mi Lim
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.4
    • /
    • pp.521-532
    • /
    • 2015
  • Purpose: The purpose of this study is to compare two multivariate cumulative sum (MCUSUM) charts designed for spatio-temporal surveillance in terms of not only temporal detection performance but also spatial detection performance. Method: Experiments under various configurations are designed and performed to test two CUSUM charts, namely SMCUSUM and RMCUSUM. In addition to average run length(ARL), two measures of spatial identification accuracy are reported and compared. Results: The RMCUSUM chart provides higher level of spatial identification accuracy while two charts show comparable performance in terms of ARL. Conclusion: The RMCUSUM chart has more flexibility, robustness, and spatial identification accuracy when compared to those of the SMCUSUM chart. We recommend to use the RMCUSUM chart if control limit calibration is not an urgent task.

Neural Network Based Camera Calibration and 2-D Range Finding (신경회로망을 이용한 카메라 교정과 2차원 거리 측정에 관한 연구)

  • 정우태;고국원;조형석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.510-514
    • /
    • 1994
  • This paper deals with an application of neural network to camera calibration with wide angle lens and 2-D range finding. Wide angle lens has an advantage of having wide view angles for mobile environment recognition ans robot eye in hand system. But, it has severe radial distortion. Multilayer neural network is used for the calibration of the camera considering lens distortion, and is trained it by error back-propagation method. MLP can map between camera image plane and plane the made by structured light. In experiments, Calibration of camers was executed with calibration chart which was printed by using laser printer with 300 d.p.i. resolution. High distortion lens, COSMICAR 4.2mm, was used to see whether the neural network could effectively calibrate camera distortion. 2-D range of several objects well be measured with laser range finding system composed of camera, frame grabber and laser structured light. The performance of 3-D range finding system was evaluated through experiments and analysis of the results.

  • PDF

Review and Suggestions of Models for Measurement System Analysis (측정 시스템 분석 모형의 고찰 및 새로운 모형의 제안)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.1
    • /
    • pp.191-195
    • /
    • 2008
  • The present study contributes reviewing and suggesting various models for measurement system analysis (MSA). Measurement errors consist of accuracy, linearity, stability, part precision, repeatability and reproducibility (R&R). First, the major content presents split-plot design, and the combination method of crossed and nested design for obtaining gage R&R. Second, we propose $\bar{x}-s$ variable control chart for calculating the gage R&R and number of distinct category. Lastly, investigating the determination of gage performance curve which establishes the control specification propagating calibration uncertainties and measurement errors is described.

A study on slim-hole neutron logging based on numerical simulation (소구경 시추공에서의 중성자검층 수치모델링 연구)

  • Ku, Bonjin;Nam, Myung Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.219-226
    • /
    • 2012
  • This study provides an analysis on results of neutron logging for various borehole environments through numerical simulation based on a Monte Carlo N-Particle (MCNP) code developed and maintained by Los Alamos National Laboratory. MCNP is suitable for the simulation of neutron logging since the algorithm can simulate transport of nuclear particles in three-dimensional geometry. Rather than simulating a specific tool of a particular service company between many commercial neutron tools, we have constructed a generic thermal neutron tool characterizing commercial tools. This study makes calibration chart of the neutron logging tool for materials (e.g., limestone, sandstone and dolomite) with various porosities. Further, we provides correction charts for the generic neutron logging tool to analyze responses of the tool under various borehole conditions by considering brine-filled borehole fluid and void water, and presence of borehole fluid.

Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer (자궁경부암의 강내치료를 위한 선량측정)

  • 김진기;김정수;김형진;권형철
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 1995
  • Dose distribution of HDR-RALS source represents an inverse square law as the distance. Difference of measurement value and calculation value according of brachytherapy. Therefore, in HDR-RALS dose calibration and calculation have an important effect in treatment of uterine cervical cancer and absorbed dose of interesting points. In intracavitary therapy, particula attention is paid for precise determination of the doses to be applied. In this report, we have discussed that the calibration of a HDR-RALS, differences between calculation dose use of isodose chart and measurement in rectum. Dose rate calibration of radiation sources are obtained from air kerma and Г factor with calibraed ion chamber for cobalt source. and used semiconductor detector for compared with measurement in phantom. Eighteen patients were treated with a HDR-RALS for intrcavitarty irradiation (ICR) using a cobalt-cesium source. Repoductivity of dose measurements were 0.3 -1.1% in phantom. The means of dose distribution was -6- +21% between calculation of isodose chart and measurement of recyum, and was same mean value upper 6.3% in measurement value than calculation does.

  • PDF

Construction of calibration models and calibrating experiment for efficient Held application of density log (밀도검층의 효과적인 현장 적용을 위한 모형 보정공 건설과 밀도 보정 기초연구)

  • Kim Ji-hoon;Kong Nam-young;Zhao Weijun;Kim Yeong-hwa
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.73-82
    • /
    • 2005
  • We constructed a series of calibration models in the campus of Kangwon National University. A series of experiment for calibrating sonde response as well as casing effect in field measurement. Here we explained the process of construction of calibrating facility which consists of three model holes of different density and three model holes of different diameter. It was discussed the calibration equations obtained from its sonde response calibration test. A density correction chart for different separation of detector from hole wall was suggested, and verified the possibility of determining true density from measurements in cased hole.

  • PDF

Calibration of a Chirp Sonar System Using Seven Tungsten Carbide Spheres of Different Sizes (크기가 다른 7개의 탄화 텅스텐 구를 이용한 Chirp 소너 시스템의 교정)

  • Lee, Dae-Jae;Lee, Kyounghoon;Jung, Bong-Kyu;Kang, Hee-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.2
    • /
    • pp.207-217
    • /
    • 2022
  • The accurate calibration of broadband echo sounders is essential for providing high quality acoustic information for fisheries applications. The increased range resolution of broadband echo sounder systems improves the detection and characterization of targets near boundaries, such as fish near the seabed. Most echo sounder systems are calibrated using tungsten-carbide (WC) spheres. For accurate calibration, it is necessary to select WC spheres of optimized diameters used frequently to calibrate echo sounder systems. For these purposes, the measured and simulated target strength (TS) data for seven WC spheres of different sizes were compared across a bandwidth of 100-200 kHz. The frequency-dependent TS pattern for the specular wave measured from two WC spheres using the fractional Fourier transform was also estimated and analyzed. Comparative results are presented for all the spheres and the best average precision of 0.15 dB was obtained for the 22 mm WC sphere.