• Title/Summary/Keyword: calibration and test institution

Search Result 6, Processing Time 0.019 seconds

Evaluation on the Measurement Capability of Gauge Blocks for National Calibration and Test Institutions (길이분야 국가교정검사기관에 대한 게이지블록의 측정능력 평가)

  • Lee, Yong Sang;Eom, Cheon Il;Kang, Chu-Shik;Eom, Tae Bong;Han, Jin Wan;Kirn, Myung Soon;Chung, Myung Sai
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.2
    • /
    • pp.62-66
    • /
    • 1996
  • Since 1980, Korea Research Institute of Standards and Science (KRISS) have performed 8 round robin tests in gauge block measurement in order to evaluate the measurement capability and the state of environment control of National Calibration and Test Institutions. Two sets of five gauge blocks (nominal size : 1, 3, 10, 25, 100 mm) having different thermal expansion coefficients for each set were circulated for the measurement, and the measurement results were collected and analyzed to evaluate the traceability to the standard of KRISS. The method and results of the test are presented.

  • PDF

Measurement of Traceability Error for Calibration Service Center Using Type S Thermocouples (S형 열전대를 이용한 교정검사기관의 소급성 오차측정)

  • Gam, Kee-Sool;Kim, Yong-Gyoo;Kim, Sun-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.43-50
    • /
    • 1995
  • We measured the traceability error for nine high temperature calibration service centers including KRISS through the round-robin test. In this test the type S thermocouple, which used as a calibration standard thermometer commonly, was accommodated as a test thermocouple. Intercomparison data of three institutions were coincident with KRISS's data within ${\pm}0.5^{\circ}C$, which was the calibration uncertainty of the type S thermocouple, but the remaining six institution's data were deviated from the assigned uncertainty level. Deviation of the intercomparison data increased gradually according to the increase of the test temperature. and the maximum difference was so large as about $2.0^{\circ}C$ at the highest test temperature, gold point. In this study we found the traceability error of high temperature calibration service center for a high temperature standard was within $2.0^{\circ}C$.

  • PDF

Interaction between two neighboring tunnel using PFC2D

  • Sarfarazi, V.;Haeri, Hadi;Safavi, Salman;Marji, Mohammad Fatehi;Zhu, Zheming
    • Structural Engineering and Mechanics
    • /
    • v.71 no.1
    • /
    • pp.77-87
    • /
    • 2019
  • In this paper, the interaction between two neighboring tunnel has been investigated using PFC2D. For this purpose, firstly calibration of PFC was performed using Brazilian experimental test. Secondly, various configuration of two neighboring tunnel was prepared and tested by biaxial test. The maximum and minimum principle stresses were 0.2 and 30 MPa respectively. The modeling results show that in most cases, the tensile cracks are dominant mode of cracks that occurred in the model. With increasing the diameter of internal circle, number of cracks decreases in rock pillar also number of total cracks decreases in the model. The rock pillar was heavily broken when its width was too small. In fixed quarter size of tunnel, the crack initiation stress decreases with increasing the central tunnel diameter. In fixed central tunnel size, the crack initiation stress decreases with increasing the quarter size of tunnel.

Numerical simulation of the effect of confining pressure and tunnel depth on the vertical settlement using particle flow code (with direct tensile strength calibration in PFC Modeling)

  • Haeri, Hadi;Sarfarazi, Vahab;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • v.25 no.4
    • /
    • pp.433-446
    • /
    • 2020
  • In this paper the effect of confining pressure and tunnel depth on the ground vertical settlement has been investigated using particle flow code (PFC2D). For this perpuse firstly calibration of PFC2D was performed using both of tensile test and triaxial test. Then a model with dimention of 100 m × 100 m was built. A circular tunnel with diameter of 20 m was drillled in the middle of the model. Also, a rectangular tunnel with wide of 10 m and length of 20 m was drilled in the model. The center of tunnel was situated 15 m, 20 m, 25 m, 30 m, 35 m, 40 m, 45 m, 50 m, 55 m and 60 m below the ground surface. these models are under confining pressure of 0.001 GPa, 0.005 GPa, 0.01 GPa, 0.03 GPa, 0.05 GPa and 0.07 GPa. The results show that the volume of colapce zone is constant by increasing the distance between ground surface and tunnel position. Also, the volume of colapce zone was increased by decreasing of confining pressure. The maximum of settlement occurs at the top of the tunnel roof. The maximum of settlement occurs when center of tunnel was situated 15 m below the ground surface. The settlement decreases by increasing the distance between tunnel center line and measuring circles in the ground surface. The minimum of settlement occurs when center of circular tunnel was situated 60 m below the surface ground. Its to be note that the settlement increase by decreasing the confining pressure.

Improving the Performance of Risk-adjusted Mortality Modeling for Colorectal Cancer Surgery by Combining Claims Data and Clinical Data

  • Jang, Won Mo;Park, Jae-Hyun;Park, Jong-Hyock;Oh, Jae Hwan;Kim, Yoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.2
    • /
    • pp.74-81
    • /
    • 2013
  • Objectives: The objective of this study was to evaluate the performance of risk-adjusted mortality models for colorectal cancer surgery. Methods: We investigated patients (n=652) who had undergone colorectal cancer surgery (colectomy, colectomy of the rectum and sigmoid colon, total colectomy, total proctectomy) at five teaching hospitals during 2008. Mortality was defined as 30-day or in-hospital surgical mortality. Risk-adjusted mortality models were constructed using claims data (basic model) with the addition of TNM staging (TNM model), physiological data (physiological model), surgical data (surgical model), or all clinical data (composite model). Multiple logistic regression analysis was performed to develop the risk-adjustment models. To compare the performance of the models, both c-statistics using Hanley-McNeil pair-wise testing and the ratio of the observed to the expected mortality within quartiles of mortality risk were evaluated to assess the abilities of discrimination and calibration. Results: The physiological model (c=0.92), surgical model (c=0.92), and composite model (c=0.93) displayed a similar improvement in discrimination, whereas the TNM model (c=0.87) displayed little improvement over the basic model (c=0.86). The discriminatory power of the models did not differ by the Hanley-McNeil test (p>0.05). Within each quartile of mortality, the composite and surgical models displayed an expected mortality ratio close to 1. Conclusions: The addition of clinical data to claims data efficiently enhances the performance of the risk-adjusted postoperative mortality models in colorectal cancer surgery. We recommended that the performance of models should be evaluated through both discrimination and calibration.

Development and Performance Validation of Thermal Control Subsystem for Earth Observation Small Satellite Flight Model (지구관측 소형위성 비행모델의 열제어계 개발 및 성능 검증)

  • Chang, Jin-Soo;Jeong, Yun-Hwang;Kim, Byung-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.12
    • /
    • pp.1222-1228
    • /
    • 2008
  • A small satellite, DubaiSat-1 FM(Flight Model), which is based on SI-200 standard bus platform and scheduled to be launched in 2008, is being developed by Satrec Initiative and EIAST(Emirates Institution for Advanced Science and Technology). The TCS(Thermal Control Subsystem) of DubaiSat-1 FM has been designed to mainly utilize passive thermal control in order to minimize power consumption, but the active control method using heaters has been applied to some critical parts. Also, thermal analysis has been performed for DubaiSat-1's mission orbit using a thermal analysis model. The thermal design is modified and optimized to satisfy the design temperature requirements for all parts according to the analysis result. The thermal control performance of DubaiSat-1 FM is verified by thermal vacuum space simulation, consisting of thermal cycling and thermal balance test. Also, to validate the thermal modeling of DubaiSat-1 FM, comparison of test results with analysis has been performed and model calibration has been completed.