• Title/Summary/Keyword: caliber

Search Result 133, Processing Time 0.031 seconds

The influence of roll caliber design on the wire rod's Wrinkle defect (선재공형이 주름흠에 미치는 영향)

  • 김준영;조용근;김용호;임규환;이영석
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.180-187
    • /
    • 1999
  • This document illustrates the relationship between the wire rod wrinkle defect and the roll caliber design. The wrinkle defect is caused by the incongruent rolling conditions of the roll caliber design, the roll adjustment, and the extracting temperature. In this document, we restrict the study scope to the roll caliber design's effect on wrinkle defect at the base of real condition of the No.2 Wire Rod mill, POSCO. There has been wrinkle defect problem in the No.2 Wire Rod Mill, POSCO for many years. The engineers of the wire rod mill have been making efforts to solve the problem. As one of the efforts, we take the samples of the wire rod in the each stands of the 2'nd wire rod mill and then analyze the samples. Through the analysis, we find out the problem of the roll caliber design. So, we suggest the roll caliber design method to be more effective to weaken the wrinkle defect.

  • PDF

caliber Design in Shape Rolling by Finite Element Method (유한요소법을 이용한 형상 압연 공정의 공형 설계)

  • 황상무
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.44-47
    • /
    • 2000
  • In industrial practice caliber design in shape rolling depends on the designer's experience which in general is obtained through costly trial-and error process. Demonstrated in this paper is an application of the finite element method to the determination of optimal caliber shapes in shape rolling of LM-Guide.

  • PDF

Process Design of Multi-Pass Shape Rolling for Manufacturing Piston Ring Wire (피스톤 링 제조용 선재의 다단 형상 압연공정 설계)

  • Kim, N.J.;Lee, K.H.;Lim, S.H.;Lee, J.M.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2017
  • Multi-pass shape rolling is performed to produce long products of arbitrary cross-sectional shapes. In the past, the multi-pass shape rolling process has been designed by the trial and error method or the experience of experts based on the empirical approach. Particularly, the design of roll caliber in shape rolling is important to improve product quality and dimensional accuracy. In this paper, the caliber design and pass schedule of multi-pass shape rolling were proposed for manufacturing piston ring wire. In order to design roll caliber, major shape parameter and dimension was determined by analysis of various caliber design. FE-simulation was conducted to verify effectiveness of proposed process design. At first, forming simulation was performed to predict shape of the product. Then, fracture of the wire was evaluated by critical damage value using normalized Cockcroft-Latham criteria. The experiment was carried out and the results are within the allowable tolerance.

A Study on the Design and Testing of 155mm Howitzer Silencer (155mm 화포의 소음기 설계 및 시험평가에 관한 연구)

  • Yeo, Chul-Mo;Park, Sung-Ho;Lee, Hae-Suk;Kim, Young-Seop;Chung, Han-Shik;Jeong, Hyo-Min
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.144-149
    • /
    • 2014
  • The silencer of 155mm caliber howitzer is developed to reduce its firing loud noise. This kind of research of a large gun was seldom because its big firing noise does not make significant effect even if to use silencer. Nowadays, military facilities became closely located civilian residential area. The noise would be regarded environmental pollution. So the noise reducing research becomes reconsidered. The previous silencer researches were only dealt with small guns as pistols and rifles moreover their theories was not properly analyzed for a large caliber silencer. The reason was previous researches of a large caliber silencer as 155mm howitzer were limited because their data based on simulation results without actual test by using computational fluid dynamics. In this study, the entire processes of silencer of 155mm caliber howitzer which were design, manufacturing, actual firing test, and analysis of its theories, were performed and showed. In particular, the actual noise of with silencer and without was measured and the results were compared to analyze the effect of silencer.

Usefulness of Small Caliber Catheter Insertion for a Spontaneous Pneumothorax (자연 공기가슴증 치료에서 소구경 도관 흉강삽입술의 유용성)

  • Kim, Eun Jung;Yoon, Sung Ho;Lee, Seung Il;Kwon, Yong Eun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.27-31
    • /
    • 2009
  • Background: The large caliber catheter used in the treatment of pneumothorax causes great damage to the chest wall and organs. The purpose of this study was to prove that the use of a smaller caliber catheter is effective in treating pneumothorax with decreasing admission period and that the recurrence rate of spontaneous pneumothorax is low. Methods: Patients who had been admitted for treatment of first time occurrence of pneumothorax between May, 2004 and December, 2008 were included in the study. The caliber of catheter used this study is 18 Guage (1.2mm). The efficacy of treatment, admission period and recurrence rate of treating pneumothorax with small caliber catheter were compared to the control group using a tube thoracostomy for treatment. Results: The admission period for primary spontaneous pneumothorax was 10.8$\pm$3.6 days for the group (n=68) using tube thoracostomy compared to 4.5$\pm$1.3 days for the group (n=31) using the small caliber catheter (p<0.05). There was no statistically significant difference in recurrence rate between the two groups. Conclusion: The use of a smaller caliber catheter for the treatment of pneumothorax reduces the admission period without a significant increase in recurrence rates.

Experimental Study for Developing Silencer Adapted by Large Caliber Gun (대구경 화포용 소음기 개발을 위한 실험적 연구)

  • Lee, Hae-Suk;Park, Sung-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.9
    • /
    • pp.593-598
    • /
    • 2015
  • In this paper, the silencer for large caliber gun to reduce the propagation of gun-generated noise was studied. The results of structural analysis and firing test were described. Structural analysis was conducted by using a commercial program, ANSYS, and showed that there was not any structural problem. The sound pressure level was diminished about 10 dB by the silencer adapted in front of the gun and the soundness of the material was verified from the internal pressure measurement. The reduction of weight, improvement of durability and speed-up of actuating device have to be studied later to improve the usability of silencer for large caliber gun.

A Muffler with Ventilation Holes for a 40 mm Medium Caliber Gun (40 mm 중구경 화포용 천공형 소음기 설계)

  • Lee, Hae-Suk;Hong, Jun-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.479-485
    • /
    • 2016
  • A 40 mm medium caliber gun to be equipped with ventilation holes is designed and manufactured in this study. The muffler used is composed of holes, blades, and several spaces in the tube. Accordingly, a numerical analysis is performed with computational fluid dynamics (CFD) before testing the muffler. The validity of the numerical analysis is examined by analyzing the differences between the measured data of the firing test and the results of the CFD analysis. The CFD analysis showed that the numerical analysis can be used positively in the muffler design because no difference exists between the results of the field test and the CFD analysis. The test result also indicated a noise reduction of approximately 10 dB. Moreover, the muzzle velocity is almost equivalent, regardless of the muffler.

Finite Element Analysis of 3 Dimensional Steady State Deformation in Multi-stand Rod and Bar Rolling (유한 요소법을 이용한 다단 선재 압연의 3차원 정상 상태 변형 해석)

  • 김홍준;김태효;황상무
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1998.03a
    • /
    • pp.134-137
    • /
    • 1998
  • Caliber design in bar and rod rolling depends on the designer's experience, which in general is acquired through costly trial-and-error process. As a prerequisite for developing a scientific approach to caliber design, we present a finite element model to simulate 3-D deformation of bars and rods occurring in multi-pass sequence. The results are compared with measurements obtained from POSCO for to assess the solution accuracy. The comparison shows that the simulation results agree well experiments.

  • PDF

Temporary Semi-Jailing Technique for Coil Embolization of Wide-Neck Aneurysm with Small Caliber Parent Artery Following Incomplete Clipping

  • Byun, Jun Soo;Kim, Jae Kyun;Lee, Hwa Yeon;Hwang, Sung Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.4
    • /
    • pp.241-244
    • /
    • 2013
  • The authors describe the use of a self-expandable stent in a temporary deployment for treatment of a very wide-neck A1 segment of anterior cerebral artery (ACA) aneurysm following incomplete clipping. A 39-year-old hypertensive man presenting with seizure-like movement underwent computed tomography, which showed acute subarachnoid hemorrhage and an A1 segment of ACA aneurysm with superior and inferior projection. He underwent surgical clipping of the aneurysm, but superior and posterior portion of wide-neck aneurysm remained. We decided to treat the remnant aneurysm using an endovascular modality. After selection of the aneurysm, coil packing was performed assisted by the temporary semi-jailing technique. The Enterprise stent (Cordis Neurovascular, Miami, FL, USA) was deployed and recaptured repeatedly for angiography to ensure safety of the small caliber parent artery. Successful semi-deployment and recapture of the stent allowed subtotal coil occlusion of the aneurysm with good anatomic and clinical results. No complications were encountered. The stent could be recaptured up to the point where the proximal end of the stent marker was aligned with distal marker band of the microcatheter, approximately 70% of the stent length. The temporary semi-jailing technique is feasible for wide-neck aneurysm with small caliber parent artery.

An Experimental Study on Installation of the Shielding Material to Reduce the Shock Noise of a Gun (화포소음 저감을 위한 차폐재 설치에 관한 실험적 연구)

  • Lee, Haesuk;Hong, Junhee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.453-461
    • /
    • 2016
  • The paper represents the experimental analysis of the shock noise of medium caliber guns when a projectile is passed through the shielding material. In the study, the shielding material was constructed and tested in three separate experiments. The shielding material was not installed for medium caliber gun in Case 1. A medium caliber gun was fully covered with shielding material in Case 2, and another one was put with shielding material near muzzle in Case 3. In each experiment, the experimental data was compared with each other. Results showed the firing shielding material achieved a significant noise reduction in $90^{\circ}$ to the noise source. Case 3 is confirmed to be better effective than Case 2 in the near field. But, the noise reduction in the far field is small in quantity due to the low frequency. The paper is considered that further study is necessary for the shielding material which can absorb a low frequency noise in the future.