A Nonlinear Analysis of Cable Stayed Bridge including Sway Vibrational Effects using Multiple Cable Elements (다수 케이블요소를 사용한 사장교의 횡방향진동을 포함한 비선형 해석)

  • Seong, Ik-Hyun;Yoon, Ki-Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.661-670
    • /
    • 2000
  • To investigate the characteristics of the dynamic response of long-span cable-stayed bridges due to various dynamic loadings likes moving traffic loads, two different 3-D cable-stayed bridge models are considered in this study. Two models are exactly the same in structural configurations but different in finite element discretization. Modal analysis is conducted using the deformed dead-load tangent stiffness matrix. A new concept was presented by using divided a cable into several elements in order to study the effect of the cable vibration (both in-plane and swinging) on the overall bridge dynamics. Futhermore case of asymmetric traffic loading clustered in one direction are also considered to study the torsional response of the bridge. The result of this study demonstrates the importance of cable vibration on the overall bridge dynamics.

  • PDF

Buffeting response control of a long span cable-stayed bridge during construction using semi-active tuned liquid column dampers

  • Shum, K.M.;Xu, Y.L.;Guo, W.H.
    • Wind and Structures
    • /
    • v.9 no.4
    • /
    • pp.271-296
    • /
    • 2006
  • The frequency of a traditional tuned liquid column damper (TLCD) depends solely on the length of liquid column, which imposes certain restrictions on its application to long span cable-stayed bridges during construction. The configuration of a cable-stayed bridge varies from different construction stages and so do its natural frequencies. It is thus difficult to apply TLCD with a fixed configuration to the bridge during construction or it is not economical to design a series of TLCD with different liquid lengths to suit for various construction stages. Semi-active tuned liquid column damper (SATLCD) with adaptive frequency tuning capacity is studied in this paper for buffeting response control of a long span cable-stayed bridge during construction. The frequency of SATLCD can be adjusted by active control of air pressures inside the air chamber at the two ends of the container. The performance of SATLCD for suppressing combined lateral and torsional vibration of a real long span cable-stayed bridge during construction stage is numerically investigated using a finite element-based approach. The finite element model of SATLCD is also developed and incorporated into the finite element model of the bridge for predicting buffeting response of the coupled SATLCD-bridge system in the time domain. The investigations show that with a fixed container configuration, the SATLCD with adaptive frequency tuning can effectively reduce buffeting response of the bridge during various construction stages.

Mechanisms of thermally induced deflection of a long-span cable-stayed bridge

  • Zhou, Yi;Sun, Limin;Peng, Zhijian
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.505-522
    • /
    • 2015
  • Variation of temperature is a primary environmental factor that affects the behavior of structures. Therefore, understanding the mechanisms of normal temperature-induced variations of structural behavior would help in distinguishing them from anomalies. In this study, we used the structural health monitoring data of the Shanghai Yangtze River Bridge, a steel girder cable-stayed bridge, to investigate the mechanisms of thermally induced vertical deflection ($D_T$) at mid-span of such bridges. The $D_T$ results from a multisource combination of thermal expansion effects of the cable temperature ($T_{Cab}$), girder temperature ($T_{Gir}$), girder differential temperature ($T_{Dif}$), and tower temperature ($T_{Tow}$). It could be approximated by multiple linear superpositions under operational conditions. The sensitivities of $D_T$ of the Shanghai Yangtze River Bridge to the above temperatures were in the following order: $T_{Cab}$ > $T_{Gir}$ > $T_{Tow}$ > $T_{Dif}$. However, the direction of the effect of $T_{Cab}$ was observed to be opposite to that of the other three temperatures, and the magnitudes of the effects of $T_{Cab}$ and $T_{Gir}$ were found to be almost one order greater than those of $T_{Dif}$ and $T_{Tow}$. The mechanisms of the thermally induced vertical deflection variation at mid-span of a cable-stayed bridge as well as the analytical methodology adopted in this study could be applicable for other long-span cable-stayed bridges.

Nonlinear Analysis of Cable-Stayed Bridges Using Energy Method (에너지법을 이용한 사장교의 비선형 해석)

  • Choi, Dong-Ho;Lee, Gi-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.187-194
    • /
    • 2003
  • This paper presents an energy method for the analysis of the in-plane ultimate load capacity of cable-stayed bridges considering deck and pylon connection. The potential energy of the whole bridge, including bridge deck, stayed cables, and pylons, and the work done by external loads are considered in the development of the bridge energy equation. Both geometric and material nonlinearities are taken into account in the analysis. The method is simple to use and has a high convergence rate.

  • PDF

Effects of Cable Rupture on Dynamic Responses of a Concrete Cable-stayed Bridge (케이블 파단이 콘크리트사장교 동적거동에 미치는 영향)

  • Kim, Yu Hee;Go, Hyeong Gyu;Kim, Jae Cheon;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.84-91
    • /
    • 2012
  • This paper aims to investigate the effects of cable rupture on the dynamic responses of concrete cable-stayed bridges in comparison with those of steel composite ones. It examines an adequate analysis method for simulating cable rupture using a time history function and evaluates the design guidelines for dynamic amplification factor (DAF). The computed DAFs from a concrete cable-stayed bridge are compared with those from a steel composite one based on the design guideline. As a conclusion, the current design guidelines for DAF may be reliable in overall but show some unstable cases despite satisfying the design guidelines, especially for concrete cable-stayed bridges.

Abnormal Response Analysis of a Cable-Stayed Bridge using Gradual Bilinear Method (Gradual Bilinear Method를 이용한 사장교의 케이블 손상응답 해석)

  • Kim, Byeong-Cheol;Park, Ki-Tae;Kim, Tae-Heon;Hwang, Ji-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.60-71
    • /
    • 2014
  • Cable-stayed bridge, which is one of the representative long-spanned bridge, needs prompt maintenances when a stay cable is damaged because it may cause structural failure of the entire bridge. Many researches are being conducted to develop abnormal behavior detection algorithms for the purpose of shortening the reaction time after the occurrence of structural damage. To improve the accuracy of the damage detection algorithm, ample observation data from various kinds of damage responses is needed. However, it is difficult to measure an abnormal response by damaging an existing bridge, numerical simulation can be an effective alternative. In most previous studies, which simulate the damage responses of a cable-stayed bridge, the damages has been considered as a load variation without regard to its stiffness variation. The analyses of using these simplification could not calculate exact responses of damaged structure, though it may reserve a sufficient accuracy for the purpose of bridge design. This study suggests Gradual Bilinear Method (GBM) which simulate the damage responses of cable-stayed bridge considering the stiffness and mass variation, and develops an analysis program. The developed program is verified from the responses of a simple model. The responses of a existing cable-stayed bridge model are analyzed with respect to the fracture delay time and damage ratio. The results of this study can be used to develop and verify the highly accurate abnormal behavior detection algorithm for safety management of architecture/large structures.

A novel method for vehicle load detection in cable-stayed bridge using graph neural network

  • Van-Thanh Pham;Hye-Sook Son;Cheol-Ho Kim;Yun Jang;Seung-Eock Kim
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.731-744
    • /
    • 2023
  • Vehicle load information is an important role in operating and ensuring the structural health of cable-stayed bridges. In this regard, an efficient and economic method is proposed for vehicle load detection based on the observed cable tension and vehicle position using a graph neural network (GNN). Datasets are first generated using the practical advanced analysis program (PAAP), a robust program for modeling and considering both geometric and material nonlinearities of bridge structures subjected to vehicle load with low computational costs. With the superiority of GNN, the proposed model is demonstrated to precisely capture complex nonlinear correlations between the input features and vehicle load in the output. Four popular machine learning methods including artificial neural network (ANN), decision tree (DT), random forest (RF), and support vector machines (SVM) are refereed in a comparison. A case study of a cable-stayed bridge with the typical truck is considered to evaluate the model's performance. The results demonstrate that the GNN-based model provides high accuracy and efficiency in prediction with satisfactory correlation coefficients, efficient determination values, and very small errors; and is a novel approach for vehicle load detection with the input data of the existing monitoring system.

Seismic Response Control of a Cable-Stayed Bridge Using Passive, Active, Semiactive and Hybrid Systems (수동, 능동, 반능동 및 복합 시스템을 이용한 사장교의 지진응답 제어)

  • ;;Spencer, B. F.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.17-29
    • /
    • 2003
  • This paper preliminarily investigates the effectiveness of various control systems, such as passive, active, semiactive and hybrid control, for seismic protection of cable-stayed bridges by examining the ASCE first generation benchmark problem for a cable-stayed bridge. This benchm.0.00000ark problem considers the cable-stayed bridge that is scheduled for completion in Missouri, USA In 2003. Seismic considerations were strongly considered in the design of this bridge due to location of the bridge and its critical role as a principal crossing of the Mississippi River. Based on detailed drawings of this cable-stayed bridge, a three-dimensional linearized evaluation model has been developed to represent the complex behavior of the bridge. A set of eighteen evaluation criteria has been developed to evaluate the capability of each control system. In this study, four passive control systems, one active control system, two semiactive control systems and three hybrid control systems are considered. Numerical simulation results show that all the control systems are effective in reducing the responses of the benchmark cable-stayed bridge under the historical earthquakes. To get good performance, however, the passive control systems need quite large control forces compared to other control systems. The simulation results also demonstrate that the passive, semiactive and hybrid control systems are robust to the stiffness uncertainty of the structure. Therefore, the semiactive and hybrid control systems are more appropriate in real applications for full-scale civil infrastructures.

Hybrid Control of a Benchmark Cable-Stayed Bridge Considering Nonlinearity of a Lead Rubber Bearing (납고무받침의 비선형성을 고려한 벤치마크 사장교의 복합제어)

  • Park, Kyu-Sik;Jung, Hyun-Jo;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.51-63
    • /
    • 2002
  • This paper presents a hybrid control strategy for seismic protection of a benchmark cable-stayed bridge, which is provided as a testbed structure for the development of strategies for the control of cable-stayed bridges. This benchmark problem considers the cable-stayed bridge that is scheduled for completion in Cape Girardeau, Missouri, USA in 2003. Seismic considerations were strongly considered in the design of this bridge due to the location of the bridge in the New Madrid seismic zone and its critical role as a principal crossing of the Mississippi river. Based on detailed drawings of this cable-stayed bridge, a three-dimensional linearlized evaluation model has been developed to represent the complex behavior of the bridge. A set of eighteen evaluation criteria has been developed to evaluate the capabilities of each control strategy. In this study, a hybrid control system is composed of a passive control system to reduce the earthquake-induced forces in the structure and an active control system to further reduce the bridge responses, especially deck displacements. Conventional base isolation devices such as lead rubber bearings are used for the passive control design and Bouc-Wen model is used to simulate the nonlinear behavior of these devices For the active control design, ideal hydraulic actuators are used and on $H_2$/LQG control algorithm is adopted. Numerical simulation results show that the performance of the proposed hybrid control strategy is quite effective compared to that of the passive control strategy and slightly better than that of the active control strategy. The hybrid control method is also more reliable than the fully active control method due to the passive control part. Therefore, the proposed hybrid control strategy can effectively be used to seismically excited cable-stayed bridges.

Guidelines of Designing Lead Rubber Bearing for a Cable-Stayed Bridge In Control Seismic Response (사장교의 지진 응답 제어를 위한 납고무 받침의 설계 기준 제안)

  • 이성진;박규식;김춘호;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.509-516
    • /
    • 2003
  • In tile design of base isolation system for building and short-span bridge, shift of the natural period of the structure is main objective. But, most long-span bridges such as a cable-stayed bridges have a number of long-period modes due to their flexibility and small structural damping. thus the design concept of base isolation system for building and short-span brigde may be difficult to use directly to these structures. However, the effectiveness of LRB for cable-stayed bridges is indicated by Ali and Abdel-Ghaffar. In this study, the design procedure and guidelines of LRB for a seismically excited cable-stayed bridge are investigated. The design properties of LRB are chosen that the design index(DI) is minimized or little changed for variation of properties. This result show that the stiffer rubber and bigger lead core size are need to cable-stayed bridges. And the seismic performance of designed LRB is also investigated. The consequences show that the perforamnce of designed LRB is better than that of Naeim-Kelly mettled designning LRB for general building structures. Moreover, the design properties of LRB are researched to several diffrent dominant frequency of earthquake. The results present that the plastic and elastic stiffness of LRB are affected by the dominant frequency of earthquake.

  • PDF