• Title/Summary/Keyword: cable vibration

Search Result 392, Processing Time 0.028 seconds

Determining minimum analysis conditions of scale ratio change to evaluate modal damping ratio in long-span bridge

  • Oh, Seungtaek;Lee, Hoyeop;Yhim, Sung-Soon;Lee, Hak-Eun;Chun, Nakhyun
    • Smart Structures and Systems
    • /
    • v.22 no.1
    • /
    • pp.41-55
    • /
    • 2018
  • Damping ratio and frequency have influence on dynamic serviceability or instability such as vortex-induced vibration and displacement amplification due to earthquake and critical flutter velocity, and it is thus important to make determination of damping ratio and frequency accurate. As bridges are getting longer, small scale model test considering similitude law must be conducted to evaluate damping ratio and frequency. Analysis conditions modified by similitude law are applied to experimental test considering different scale ratios. Generally, Nyquist frequency condition based on natural frequency modified by similitude law has been used to determine sampling rate for different scale ratios, and total time length has been determined by users arbitrarily or by considering similitude law with respect to time for different scale ratios. However, Nyquist frequency condition is not suitable for multimode system with noisy signals. In addition, there is no specified criteria for determination of total time length. Those analysis conditions severely affect accuracy of damping ratio. The focus of this study is made on the determination of minimum analysis conditions for different scale ratios. Influence of signal to noise ratio is studied according to the level of noise level. Free initial value problem is proposed to resolve the condition that is difficult to know original initial value for free vibration. Ambient and free vibration tests were used to analyze the dynamic properties of a system using data collected from tests with a two degree-of-freedom section model and performed on full bridge 3D models of cable stayed bridges. The free decay is estimated with the stochastic subspace identification method that uses displacement data to measure damping ratios under noisy conditions, and the iterative least squares method that adopts low pass filtering and fourth order central differencing. Reasonable results were yielded in numerical and experimental tests.

Unsupervised Vortex-induced Vibration Detection Using Data Synthesis (합성데이터를 이용한 비지도학습 기반 실시간 와류진동 탐지모델)

  • Sunho Lee;Sunjoong Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.5
    • /
    • pp.315-321
    • /
    • 2023
  • Long-span bridges are flexible structures with low natural frequencies and damping ratios, making them susceptible to vibrational serviceability problems. However, the current design guideline of South Korea assumes a uniform threshold of wind speed or vibrational amplitude to assess the occurrence of harmful vibrations, potentially overlooking the complex vibrational patterns observed in long-span bridges. In this study, we propose a pointwise vortex-induced vibration (VIV) detection method using a deep-learning-based signalsegmentation model. Departing from conventional supervised methods of data acquisition and manual labeling, we synthesize training data by generating sinusoidal waves with an envelope to accurately represent VIV. A Fourier synchrosqueezed transform is leveraged to extract time-frequency features, which serve as input data for training a bidirectional long short-term memory model. The effectiveness of the model trained on synthetic VIV data is demonstrated through a comparison with its counterpart trained on manually labeled real datasets from an actual cable-supported bridge.

An Experimental Study on the Galloping of Inclined Cables

  • Kim, Han-Soo;Lee, Do-Hyung;Kim, Seok-Jung
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.137-144
    • /
    • 2002
  • A series of wind tunnel tests was conducted to investigate the existence of the galloping instability of inclined dry cables and also to Identify the influence of some parameters on it. These parameters are the structural damping and cable surface roughness, which may have significant impact on the vibration characteristics. The test results showed both the divergent type of galloping instability and the limited amplitude high wind speed vortex shedding excitation. Galloping instability was observed in only one case. Parametric study shows that the vortex shedding oscillation can be easily suppressed with an increase of structural damping. It was also shown that the instability criterion indicated by earlier research was too conservative compared to the results obtained from the present study.

  • PDF

The discussion on the Plasma blasting Experimentation (Plasma파암 실험토론회)

  • 박철화
    • Explosives and Blasting
    • /
    • v.16 no.3
    • /
    • pp.35-48
    • /
    • 1998
  • An overview of the plasma rock fragmentation system, the first commercial application of plasma blasting, is presented. Plasma blasting is based on the fast delivery of stored electrical energy to fracture the rock. The capacitor bank, switching device, cable and blasting electrode employed in the system are described. Utilization of the chemical energy delivered from the electrolyte and the development of a large charge transfer switch using pseudospark enabled the commerciailzaion. The vibration and noise level of the blasting is acceptable in the most ground breaking.

  • PDF

Sensitivity and vibration reduction of buffeting induced resonance of hangers

  • Zhang, Zhitian;Zhang, Weifeng
    • Wind and Structures
    • /
    • v.25 no.1
    • /
    • pp.39-61
    • /
    • 2017
  • Buffeting induced resonance (BIR) of hangers on long-suspension bridges is briefly reviewed, including mechanism and experimental verification. Taken the Xihoumen suspension bridge as a numerical example, sensitivities of the BIR of hangers to wind properties are investigated, including types of wind spectrum, turbulence intensity, and spacial coherence of wind fluctuations. Numerical simulations indicate that the BIR of hangers occur to both cases of different wind spectra, showing that it is insensitive to types of wind spectrum. On the other hand, it is found that the turbulence intensity affects buffeting of main cables almost in a linear manner, and so it does to the BIR of the hangers; however, the resonance factors, namely the ratio of the response of the hanger to that of the main cable, are little affected by the turbulence intensity. The spacial coherence of the wind fluctuations, although plays an important role on the buffeting responses of the main structure, has no substantial effects on the BIR of the hangers. Finally, replacement of steel strand with CFRP material has been verified as a very effective countermeasure against the BIR of hangers.

Determination of flutter derivatives by stochastic subspace identification technique

  • Qin, Xian-Rong;Gu, Ming
    • Wind and Structures
    • /
    • v.7 no.3
    • /
    • pp.173-186
    • /
    • 2004
  • Flutter derivatives provide the basis of predicting the critical wind speed in flutter and buffeting analysis of long-span cable-supported bridges. In this paper, one popular stochastic system identification technique, covariance-driven Stochastic Subspace Identification(SSI in short), is firstly presented for estimation of the flutter derivatives of bridge decks from their random responses in turbulent flow. Secondly, wind tunnel tests of a streamlined thin plate model and a ${\Pi}$ type blunt bridge section model are conducted in turbulent flow and the flutter derivatives are determined by SSI. The flutter derivatives of the thin plate model identified by SSI are very comparable to those identified by the unifying least-square method and Theodorson's theoretical values. As to the ${\Pi}$ type section model, the effect of turbulence on aerodynamic damping seems to be somewhat notable, therefore perhaps the wind tunnel tests for flutter derivative estimation of those models with similar blunt sections should be conducted in turbulent flow.

Safety Assurance of Dropper Clamp in Overhead Catenary System(I) (전차선로 드롭바 클램프 안전성 확보(I))

  • Lee, Ki-Won;Cho, Yong-Hyeon;Park, Young;Min, Byung-Il;Kwon, Sam-Young;Seok, Chang-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.223-226
    • /
    • 2007
  • In the electrical railway, for the improvement of a train speed, it is necessary to study not only the dynamic behaviors of overhead catenary system but the fatigue behaviors of components for a safety assurance according to the increase of vibration level. One of the critical components in the system is a dropper. Therefore, the dynamic force acting on a dropper was measured in the Chungbuk Line and analyzed to figure out the dynamic characteristics the dropper. And in order to assure the safety of dropper clamp and cable, we proposed a test facility as well as test method based on the test results For the further study, we will measure the dynamic forces in the conventional line and high-speed line and make up the test condition, so that the safety of dropper clamps can be assured.

  • PDF

A vibration Analysis of Cable-type Power Transformer Winding by the Pseudospectral Method (Pseudospectral를 이용한 케이블 권선형 배전용 변압기 권선의 진동모드 해석)

  • Chung, Hyun-Koo;Wo, Sung-Hyun;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.83-85
    • /
    • 2008
  • 본 논문은 변압기의 대부분 고장원인이 되는 권선 간의 단자 시 발생하는 진동을 수치적으로 계산하고 전자력 계산을 위한 방법으로 Pseudospectral Method을 적용하여 단락권선사이의 강제진동해석을 수행하였다. 나선형권선의 방정식은 Chebyshev다항식 시리즈의 확장과 Gauss-Lobatto collocation 과정을 수행되어진다. 알고리즘 검증을 위하여 22.9kV/220V, 1000kVA 용량의 케이블 타입의 변압기의 FEM 시물레이션 결과와 이론적 수치적계산과 함께 비교하였다.

  • PDF

Performance Evaluation of Hinge Driving Separation Nut-type Holding and Releasing Mechanism Triggered by Nichrome Burn Wire

  • LEE, Myeong-Jae;LEE, Yong-Keun;OH, Hyun-Ung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.4
    • /
    • pp.602-613
    • /
    • 2015
  • As one of the mission payloads to be verified through the cube satellite mission of Cube Laboratory for Space Technology Experimental Project (STEP Cube Lab), we developed a hinge driving separation nut-type holding and releasing mechanism. The mechanism offers advantages, such as a large holding capacity and negligible induced shock, although its activation principle is based on a nylon cable cutting mechanism triggered by a nichrome burn wire generally used for cube satellite applications for the purpose of holding and releasing onboard appendages owing to its simplicity and low cost. The basic characteristics of the mechanism have been measured through a release function test, static load test under qualification temperature limits, and shock measurement test. In addition, the structural safety and operational functionality of the mechanism module under launch and on-orbit environments have been successfully demonstrated through a vibration test and thermal vacuum test.

Wind Tunnel Testing of a Concrete Pylon for Long Span Cable-Stayed Bridge (장대 사장교 콘크리트 주탑의 풍동실험 연구)

  • 윤태양
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.239-248
    • /
    • 1994
  • Wind tunnel tests and analyses of the response of the concrete pylon for the Seo Han Grand Bridge were conducted using aeroelastic model technique. A 1/250 scale aeroelastic model was used to measure the responses of the pylon at the several critical locations and to find any possible vibrational behavior. In order to confirm the model design and fabrication, natural frequencies and mode shapes measured from the model were compared with those from the calculation. Tests were conducted under the various angles ranging from $0^{\circ}$ to $90^{\circ}$ to find the critical angle of the wind. In order to evaluate the sensitivity of the response to changes in structural damping, a series of tests were conducted with two different values of structural damping such as 0.2% and 1.0% of critical. Additional tests were also conducted considering construction sequence.

  • PDF