• Title/Summary/Keyword: cable stripping

Search Result 5, Processing Time 0.017 seconds

A Study on Shield Wire Stripping of Micro Coaxial Cable for Medical Device Using Nd:YAG Laser (Nd:YAG 레이저를 이용한 의료기기용 마이크로 동축케이블의 실드선 탈피에 관한 연구)

  • Lee, Jeong-Wan;Kim, Jung-Hoon
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.35-41
    • /
    • 2006
  • Recently, as ultrasonic medical devices are gradually developed, many of those requires smaller and more precision coaxial cables in probe. So, the use of micro coaxial cable becomes an efficient solution for ultrasonic machine. However, there are many difficulties in stripping micro coaxial cable by traditional mechanical process. In this paper, we use the Nd-YAG laser for the efficient stripping of conduct wire of cable. We propose a new method to strip the shield wire of micro coaxial cable. Through some experiments, we found that there is a new possibility in the proposed method. Also, in order to enhance the performance, we propose a preprocess of the cable before stripping.

  • PDF

Shield Wire Stripping of Micro Coaxial Cable for Medical Device Using Laser (레이저를 이용한 의료기기용 미세 동축케이블의 실드선 탈피)

  • Lee, Jeong-Wan;Kim, Jung-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.9
    • /
    • pp.64-71
    • /
    • 2009
  • Recently as ultrasonic medical devices are gradually developed, many of those require smaller and more precision coaxial cables in the probe. So, the use of micro coaxial cable becomes an efficient solution for ultrasonic machine. However, there are many difficulties in stripping micro coaxial cable by traditional mechanical process. In this paper we use the Nd:YAG laser for the efficient striping of conduct wire of cable. Through some experiments, we found that there is a new possibility in the proposed method. Also, we propose a pre-process of the cable before stripping in order to enhance the performance.

Evaluation of Separation on the Copper Recovery from Jelly filled type Cable (젤리충전통신케이블의 구리회수를 위한 친환경적 분리기술평가)

  • Min, Dal-Ki;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.21-26
    • /
    • 2003
  • The generation of waste cable has been continuously increased as a production of electrical and communication media are extended. The current recovery methods, such as mechanical peeling, incineration, solvent extraction and pyrolysis, seems inadequate because they are either hard to apply in some cases or environmentally unacceptable. It has been shown that copper can be effectively separated from the jelly filled type cables using a soybean oil treatment method. As a result, jelly compound is vanished from the wire by soybean oil bath and waste wires are separated copper and PE by the mechanical chipper. This is a more environmentally friendly method than burning, and considerably faster than Stripping.

Multiplexed Hard-Polymer-Clad Fiber Temperature Sensor Using An Optical Time-Domain Reflectometer

  • Lee, Jung-Ryul;Kim, Hyeng-Cheol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Optical fiber temperature sensing systems have incomparable advantages over traditional electrical-cable-based monitoring systems. However, the fiber optic interrogators and sensors have often been rejected as a temperature monitoring technology in real-world industrial applications because of high cost and over-specification. This study proposes a multiplexed fiber optic temperature monitoring sensor system using an economical Optical Time-Domain Reflectometer (OTDR) and Hard-Polymer-Clad Fiber (HPCF). HPCF is a special optical fiber in which a hard polymer cladding made of fluoroacrylate acts as a protective coating for an inner silica core. An OTDR is an optical loss measurement system that provides optical loss and event distance measurement in real time. A temperature sensor array with the five sensor nodes at 10-m interval was economically and quickly made by locally stripping HPCF clad through photo-thermal and photo-chemical processes using a continuous/pulse hybrid-mode laser. The exposed cores created backscattering signals in the OTDR attenuation trace. It was demonstrated that the backscattering peaks were independently sensitive to temperature variation. Since the 1.5-mm-long exposed core showed a 5-m-wide backscattering peak, the OTDR with a spatial resolution of 40 mm allows for making a sensor node at every 5 m for independent multiplexing. The performance of the sensor node included an operating range of up to $120^{\circ}C$, a resolution of $0.59^{\circ}C$, and a temperature sensitivity of $-0.00967dB/^{\circ}C$. Temperature monitoring errors in the environment tests stood at $0.76^{\circ}C$ and $0.36^{\circ}C$ under the temperature variation of the unstrapped fiber region and the vibration of the sensor node. The small sensitivities to the environment and the economic feasibility of the highly multiplexed HPCF temperature monitoring sensor system will be important advantages for use as system-integrated temperature sensors.

Determination of Iron in Seawater by Adsorptive Stripping Voltammetry (흡착 벗김 전압전류법에 의한 해수중 미량 철의 정량)

  • Czae, Myung-Zoon;Kim, Kyung;Kwon, Young-Soon
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.3
    • /
    • pp.186-190
    • /
    • 1995
  • A simple procedure, readily available at low cost with a sensitivity sufficient to determine trace levels of iron in seawater is proposed, which utilizes adsorptive accumulation of the iron/catechol complex on the mercury drop electrode in a borate medium of pH 8.0. Optimal conditions include a solution concentration of 2 mM catechol, 2.5 mM borate and a pH of 8.0, an accumulation potential of - 0.25 V is applied for 1∼3 min, and the potential scan is in the differential pulse mode. The limit of detection is 1.5 nM Fe using a preconcentration time of 3 min. The interference from copper can be eliminated and baseline slope is greatly improved, because its peak is well separated from that of iron in the proposed medium.

  • PDF