• Title/Summary/Keyword: cable sensor

Search Result 270, Processing Time 0.024 seconds

Sensorless Vector Control Using Tabu Search Algorithm (타부 탐색을 이용한 센서리스 벡터 제어)

  • Lee, Yang-Woo;Park, Kyung-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2625-2632
    • /
    • 2009
  • Recently, a speed control method of induction motor by vector control theory is applied to highly efficient industrial field. The speed sensors attached to motor are used for detection of rotating speed. In the case using speed sensor, the installation of cable for minimization of electric noise, weaken maintenance, increase of price are demerit. Therefore the study of speed sensorless vector control theory performed activity. The design of sensorless vector controller for induction motor using tabu search is studied. The proposed sensorless vector control for Induction Motor is composed of two parts. The first part is for optimizing the speed estimation with initial PI parameters. The second part is for optimizing the speed control with initial PI parameters using tabu search. Proposed tabu search is improved by neighbor solution creation using Triangular random distribution. In order to show the usefulness of the proposed method, we apply the proposed controller to the sensorless speed control of an actual AC induction Motor System. The performance of this approach is verified through simulation and the experiment.

Design and Data Analysis of Signal Measurement System for In-Building Propagation Characteristics based on Variable Short Signature Sequences (가변의 짧은 시그니처 시퀀스 기반 건물 내 메시지 전달특성 측정시스템 설계)

  • Kim, Jeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.10-14
    • /
    • 2015
  • Recently, the collection of the sensor data and its analysis become important as the smart buildings equipped with the various sensors appear as a usual scene. The interconnection through the wire cable among the sensors is indispensible because of the information collections such as the temperature, the humidity, and the luminance in the rooms and the hallways for the effective management of the in-building energies. However, these interconnections through the cabling will be very costly, time-consuming, and a difficult task since they will cause some damages to the buildings. Therefore, the interconnections through the unwired connections are required in terms of the deployment effectiveness such as time and cost In this paper, the design and the short sequence operation appropriateness are confirmed through the simulation of the signal measurement system for in-building propagation characteristics based on short signature sequence and the analysis of the system characteristics based on the false alarm probability is performed thereafter.

Development of Long-perimeter Intrusion Detection System Aided by deep Learning-based Distributed Fiber-optic Acoustic·vibration Sensing Technology (딥러닝 기반 광섬유 분포 음향·진동 계측기술을 활용한 장거리 외곽 침입감지 시스템 개발)

  • Kim, Huioon;Lee, Joo-young;Jung, Hyoyoung;Kim, Young Ho;Kwon, Jun Hyuk;Ki, Song Do;Kim, Myoung Jin
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.24-30
    • /
    • 2022
  • Distributed fiber-optic acoustic·vibration sensing technology is becoming increasingly popular in many industrial and academic areas such as in securing large edifices, exploring underground seismic activity, monitoring oil well/reservoir, etc. Long-range perimeter intrusion detection exemplifies an application that not only detects intrusion, but also pinpoints where it happens and recognizes kinds of threats made along the perimeter where a single fiber cable was installed. In this study, we developed a distributed fiber-optic sensing device that measures a distributed acoustic·vibration signature (pattern) for intrusion detection. In addition, we demontrate the proposed deep learning algorithm and how it classifies various intrusion events. We evaluated the sensing device and deep learning algorithm in a practical testbed setup. The evaluation results confirm that the developed system is a promising intrusion detection system for long-distance and seamless recognition requirements.

Structural Health Monitoring System for Large-Bridge-Based LoRa LPWAN (LoRa LPWAN 기반의 대형 교량 구조건전성 모니터링 시스템)

  • Jin-Oh Park;Ki-Don Kim;Kyung-soo Kim;Sang-Heon Park
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.1
    • /
    • pp.49-56
    • /
    • 2023
  • With the development of technology worldwide, bridges are becoming larger, and the number of old bridges is also rapidly increasing. Monitoring the structural health of large, aging bridges is essential to preventing large-scale accidents. In this study, the application of a LoRa low-power wide-area network (LPWAN)-based wireless measurement system was investigated, and a LoRa wireless measurement system was established in the cable-stayed bridge section of Cheonsa Bridge, located in Shinan-gun, Jeollanam-do, Korea. The applicability of the LoRa LPWAN-based wireless monitoring system to large marine bridges was reviewed by comparing the performance and economic feasibility with wire-based monitoring systems that were built and operated by establishing a measurement system for the pylons, cables, and reinforcing girders of the bridge.

Development of Non-Contact Fiber Jumper Cord and Evaluation of Light Transmission Performance (비접촉식 광 점퍼 코드 개발 및 광 전송 성능 평가)

  • Kim, Heonyoung;Kang, Donghoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.399-405
    • /
    • 2016
  • Recently, fiber optic sensors, which have many advantages are being applied in various fields by replacing conventional electric sensors. To transmit the light signals between an interrogator and a sensor head, optical components such as an optical adaptor and optical jumper cords are generally used. When signals are transmitted using an adaptor, the end surface of each jumper cord is faced together. If alien substances exist on the core surface of an optical fiber, those can cause light transmission loss and signal disappearance. For this reason, non-contact fiber jumper cords are developed to overcome the problems that require continual attention. The light transmission performance of non-contact fiber jumper cords are also evaluated. From the test results, conventional fiber jumper cords are unable to transmit the signals over 2 mm cavity between the ends of both cords. Otherwise, non-contact fiber jumper cords can transmit the signals with stability up to the cavity of 7 mm though they have more transmission loss than the conventional ones. Consequently, non-contact fiber jumper cords that have better signal stability than conventional ones in environments are highly recommended in field applications, especially if they play a role as a cable for signal transmission between fiber optic sensors.

A Study on Stabilization of Underwater TAS Winch System Deploy/Recover Operation Performance (수중용 TAS윈치 전개/회수 성능 안정화 방안에 관한 연구)

  • Chang, Ho-Seong;Cho, Kyu-Lyong;Hwang, Jae-Gyo;Lee, Sang-Yong;Kim, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.472-482
    • /
    • 2019
  • This paper describes the stabilization of underwater TAS winch system Deploy/Recover operation performance. TAS winch installed on the stern of submarine performs to deploy/recover sensor, towing cable and rope tail which is deployed from the stern and separated from submarine itself. Also TAS winch provides transmission path of power to the sensor and data transmitting/receiving path which data are acquired from underwater environment like sound, depth and temperature. At the step of TAS winch evaluation test, sporadic standstill and rotating speed oscillation phenomenon were occurred. Winch motor provides the available torque to deploy/recover TAS and root cause analysis to the winch motor was done to find exact reason to sporadic malfunction. When winch motor was disassembled, eccentricity of rotor, slip-ring and the other composition part for winch motor were found. These might cause magnetic field distortion. To make TAS winch system more stable and block magnetic field distortion, this paper suggests methods to enhance fixing status installed in winch motor. For reliable data acquisition for TAS winch operation, the deploy/recover function of the improved type of TAS winch was verified in LBTS making similar condition with sea status. At the end of stage, improved type of TAS winch was tested on some functions not only deploy/recover function, but sustainability of TAS operation on specific velocity, steering angle of submarine in the sea trial. Improved type of TAS winch was verified in accordance with design requirement. Also, validity of suggested methods were verified by the sea trial.

Temperature Compensation of Optical FBG Sensors Embedded Tendon for Long-term Monitoring of Tension Force of Ground Anchor (광섬유 센서 내장형 텐던을 이용한 그라운드 앵커의 장기 장력모니터링을 위한 온도보상)

  • Sung, Hyun-Jong;Kim, Young-Sang;Kim, Jae-Min;Park, Gui-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.13-25
    • /
    • 2012
  • Ground anchor method is one of the most popular reinforcing technology for slope in Korea. For the health monitoring of slope which is reinforced by permanent anchor for a long period, monitoring of the tension force of ground anchor is very important. However, since electromechanical sensors such as strain gauge and V/W type load cell are also subject to long-term risk as well as suffering from noise during long distance transmission and immunity to electromagnetic interference (EMI), optical FBG sensors embedded tendon was developed to measure strain of 7-wire strand by embedding FBG sensor into the center king cable of 7-wire strand. This FBG sensors embedded tendon has been successfully applied to measuring the short-term anchor force. But to adopt this tendon to long-term monitoring, temperature compensation of the FBG sensors embedded tendon should be done. In this paper, we described how to compensate the effect in compliance with the change of underground temperature during long-term tension force monitoring of ground anchors by using optical fiber sensors (FBG: Fiber Bragg Grating). The model test was carried out to determine the temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon. The determined temperature sensitivity coefficient ${\beta}^{\prime}=2.0{\times}10^{-5}/^{\circ}C$ was verified by comparing the ground temperatures predicted from the proposed sensor using ${\beta}^{\prime}$ with ground temperatures measured from ground thermometer. Finally, temperature compensations were carried out based on ${\beta}^{\prime}$ value and ground temperature measurement from KMA for the tension force monitoring results of tension type and compression type anchors, which had been installed more than 1 year before at the test site. Temperature compensated tension forces are compared with those measured from conventional load cell during the same measuring time. Test results show that determined temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon is valid and proposed temperature compensation method is also appropriate from the fact that the temperature compensated tension forces are not dependent on the change of ground temperature and are consistent with the tension forces measured from the conventional load cell.

Fabrication and Reliability Properties of Optical Fiber Sensor Cable for Detecting Intruders (침입자 감지용 광섬유 센서 케이블 제작 및 신뢰성 특성)

  • Kim, Jun-Hyong;Jung, Yoon-Seok;Sung, Tae-Kyung;An, Bo-Young;Park, In-Chul;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.208-208
    • /
    • 2009
  • 최근 광섬유 센서기술의 수요는 전 산업분야에 걸쳐 높아지고 있으며, 이에 비례하여 기업 간, 국가 간 경쟁이 첨예화되고 있다. 또한 소형화, 경량화, 고성능화 센서에 대한 요구도 높아지고 있어 종래의 각종 센서들의 형태와 개선을 위한 연구개발이 매우 활발하게 전개되고 있으므로 이를 대체할 수 있는 광섬유 센서의 수요가 급격히 늘어날 전망이다. 기존 침입자 감지 시스템은 태풍, 낙뢰, 폭설, 폭우 등의 기상변화나 지반 흔들림, 통행차량 진동 및 전자기 간섭 등에 영향을 받아 오작동, 오경보가 빈번히 발생된다. 이러한 문제의 해결책으로 광섬유 센서 케이블을 이용한 시스템이 대안으로 부각되고 있다. 현재 국내에서 군부대, 공항을 중심으로 펜스와 휴전선 철책에 힘입자 감지를 위하여 도입되고 있다. 광섬유 센서 케이블을 사용하는 광망경비시스템은 광섬유 센서 케이블을 그물망 형태(광망)로 만들어 경계 지역에 설치된다. 광망경비시스템의 원리는 광섬유에 광펄스를 입사시켜 순환시키는데 침입자가 광망을 절단하거나 외력을 가할 경우 발생되는 레일리 산란에 기인하는 후방산란과 접속점과 파단점에서 생기는 반사광을 OTDR(Optical Time Domain Reflectometer)로 검출하여 침입상황 및 침입위치를 탐지한다. 그러나 이러한 침입자 감지를 위한 광망경비시스템의 핵심부품인 광섬유 센서 케이블은 기존에 전량 해외수입에 의존하고 있는 실정이며, 지금까지 국내에서 생산하기 위한 제작 기술과 노하우가 초보단계에 머물러 있다. 이러한 광섬유 센서 케이블 제작에 있어서 중요한 부분이 패키징 기술이라 할 수 있다. 이는 광섬유 센서를 일반적인 피복 구조로 패키징하게 되면, 센서 고유의 특성이 패키징 과정과 운반과정, 포설과정에서 변하게 되고 센서로써의 신뢰성이 크게 저하된다. 본 연구에서는 힘입자 감지용 광섬유 센서 케이블의 설계와 제작을 위한 제조공법을 확립하고, 이를 이용해 제작된 광섬유 센서 케이블의 신뢰성 특성을 평가하였다. 설계 제작된 광섬유 센서 케이블의 구조는 멀티모드광섬유(MMF) 에 0.9 mm Tight buffer를 코팅하고, 광심선 주위에 아라미드 얀을 삽입시킨 후 고문자 수지를 적용하여 외부 피복 (jacket)을 하였다. 제작된 광섬유 센서 케이블의 외경 측정결과 기준치 ($2.95\;{\pm}\;0.03$ mm)를 모두 만족하였고, 850 nm 파장에서의 광 손실 측정 결과 4.0 dB/km 이하였다. 또한 주요 항목의 신뢰성 특성 시험결과, 인장강도는 8~10 kg의 인장력을 갖으며 온도순환시험 ($-30^{\circ}C\;{\sim}\;+75^{\circ}C$)에서의 광 손실은 0.6 dB 이하로 나타나 침입자 감지용 광섬유 센서 케이블로 적합함을 확인할 수 있었다.

  • PDF

Fabrication of Three-Dimensional Scanning System for Inspection of Mineshaft Using Multichannel Lidar (다중채널 Lidar를 이용한 수직갱도 조사용 3차원 형상화 장비 구현)

  • Soolo, Kim;Jong-Sung, Choi;Ho-Goon, Yoon;Sang-Wook, Kim
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.451-463
    • /
    • 2022
  • Whenever a mineshaft accidentally collapses, speedy risk assessment is both required and crucial. But onsite safety diagnosis by humans is reportedly difficult considering the additional risk of collapse of the unstable mineshaft. Generally, drones equipped with high-speed lidar sensors can be used for such inspection. However, the drone technology is restrictively applicable at very shallow depth, failing in mineshafts with depths of hundreds of meters because of the limit of wireless communication and turbulence inside the mineshaft. In previous study, a three-dimensional (3D) scanning system with a single channel lidar was fabricated and operated using towed cable in a mineshaft to a depth of 200 m. The rotation and pendulum movement errors of the measuring unit were compensated for by applying the data of inertial measuring unit and comparing the similarity between the scan data of the adjacent depths (Kim et al., 2020). However, the errors grew with scan depth. In this paper, a multi-channel lidar sensor to obtain a continuous cross-sectional image of the mineshaft from a winch system pulled from bottom upward. In this new approach, within overlapped region viewed by the multi-channel lidar, rotation error was compensated for by comparing the similarity between the scan data at the same depth. The fabricated system was applied to scan 0-165 m depth of the mineshaft with 180 m depth. The reconstructed image was depicted in a 3D graph for interpretation.

Verification of Multi-point Displacement Response Measurement Algorithm Using Image Processing Technique (영상처리기법을 이용한 다중 변위응답 측정 알고리즘의 검증)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.297-307
    • /
    • 2010
  • Recently, maintenance engineering and technology for civil and building structures have begun to draw big attention and actually the number of structures that need to be evaluate on structural safety due to deterioration and performance degradation of structures are rapidly increasing. When stiffness is decreased because of deterioration of structures and member cracks, dynamic characteristics of structures would be changed. And it is important that the damaged areas and extent of the damage are correctly evaluated by analyzing dynamic characteristics from the actual behavior of a structure. In general, typical measurement instruments used for structure monitoring are dynamic instruments. Existing dynamic instruments are not easy to obtain reliable data when the cable connecting measurement sensors and device is long, and have uneconomical for 1 to 1 connection process between each sensor and instrument. Therefore, a method without attaching sensors to measure vibration at a long range is required. The representative applicable non-contact methods to measure the vibration of structures are laser doppler effect, a method using GPS, and image processing technique. The method using laser doppler effect shows relatively high accuracy but uneconomical while the method using GPS requires expensive equipment, and has its signal's own error and limited speed of sampling rate. But the method using image signal is simple and economical, and is proper to get vibration of inaccessible structures and dynamic characteristics. Image signals of camera instead of sensors had been recently used by many researchers. But the existing method, which records a point of a target attached on a structure and then measures vibration using image processing technique, could have relatively the limited objects of measurement. Therefore, this study conducted shaking table test and field load test to verify the validity of the method that can measure multi-point displacement responses of structures using image processing technique.