• Title/Summary/Keyword: cable length

Search Result 372, Processing Time 0.031 seconds

Design and development of VSI Optical Adapter for high speed transmission of VLBI observation data (VLBI 관측데이터 초고속 전송을 위한 VSI 광변환 송수신 장치의 설계 및 개발)

  • Oh, Se-Jin;Roh, Duk-Gyoo;Yeom, Jae-Hwan;Jung, Jin-Seung;Jung, Dong-Kyu;Oh, Chung-Sik;Ozeki, Kensuke;Onuki, Hirofumi;Harada, Keniichi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.4
    • /
    • pp.261-269
    • /
    • 2013
  • This paper describes the design and development of VSI (VLBI standard interface) optical adapter for transmitting VLBI(Very long baseline interferometry) observation data with optical signal. VSI cable comprised of 80-line is being used for observed data transmission with maximum length of 5-meter between playbacks (Mark5B, VERA2000) and raw VLBI data buffer (RVDB), RVDB and VLBI correlation subsystem (VCS) in Daejeon correlator. It has a plan to conduct the data processing for 16-stations and introduce the 14 RVDB systems in near future. And data loss frequently occurred because of trouble of VSI cable MDR80 connector. By considering the data loss by connector error of VSI cable, RVDB system extension plan, effective space usage and long distance data transmission(e-VLBI), the VSI optical adapter was proposed and developed for effectively transmitting and receiving VLBI data through optical signal. In order to confirming the performance of developed VSI optical adapter, the experiments for data transmission was conducted between playback and RVDB system, and confirmed that data transmission was clearly done without any data loss.

Georadar System Using Network-Analyzer (네트웍 분석기를 이용한 레이다탐사 시스템의 구현)

  • Cho Seong-Jun;Kim Jung-Ho;Lee Seoung Kon;Son Jeong-Sul;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.272-279
    • /
    • 2002
  • During field survey of ground penetrating radar or borehole radar, we often encounter some problems which could be solved easily by modifying structure of the system such as antenna length, shape or array. In addition, it is necessary that the user could easily modify configuration of the radar system na test various array of antennas in order to verify and confirm numerical modeling results concerning radar antennas. We have developed network-analyzer-based, stepped-frequency georadar system. This system had been comprised with coaxial cable to confirm possibility of the system, then we have upgraded the system to use optical cable that is composed of optical/electric transducers, electric/optical transducers, amp, pre-amp and antennas. The software for the aquisition of data has been developed to control the system automatically using PC with GPIB communication and to display the obtained data graphically. We have tested the system in field survey na the results have been compared with those of RAMAC/GPR system.

Effect of the Tapered Angle on the Ultimate Load Factors of PPWS Sockets in Main Cables of Suspension Bridges (현수교 PPWS용 소켓의 내벽 경사각이 소켓의 극한 하중계수에 미치는 영향)

  • Yoo, Hoon;Lee, Sung-Hyung;Seo, Ju-Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.47-59
    • /
    • 2013
  • Ultimate load factors of PPWS(Prefabricated Parallel Wire Strand) sockets in main cables of suspension bridges are studied with respect to the tapered angles of the inner surface of sockets. After briefly reviewing the current design method, 15 numbers of finite element models of sockets are prepared by varying the number of wires in a strand and the tapered angles. The finite element models are updated by comparing experimental and numerical results, so that the models can reflect the real behavior of sockets. The stress distributions at the first yielding and ultimate states are analyzed by performing the incremental load analysis using ABAQUS. It is concluded that the optimized tapered angle of sockets should be determined at the specific angle between the results of verification equations of the required bonding length and stress resistance length.

An estimated angle of attack of a cambered otter board in a bottom trawl using three dimensional position (저층 트롤에서 3차원 위치를 이용한 만곡형 전개판의 영각 추정)

  • Go, Gwang Su;Chol, Bong Kon;Bae, Jae Hyun;Cho, Seong-Ok;Won, Sung-Jae;Yoon, Hong Keun;Park, Hae-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.1
    • /
    • pp.26-34
    • /
    • 2015
  • The angle of attack of a cambered otter board in a bottom trawl was estimated using a three-dimensional semi-analytic treatment of a towing cable (warp) system that was applied to the field experiments of a bottom trawl obtained by the Scanmar system. The equilibrium condition of the horizontal component and vertical component of forces was used to the three forces acting on the otter board in the horizontal plane. Those forces were the force on the warp at the bracket, hydrodynamic lift and drag forces on the otter board and the force on the hand rope attached just behind the otter board. Also the equilibrium of moment about the front edge of the otter board was used to find out the angle of attack of the cambered otter board. When the warp length was 120m and 180m long and the towing speed was between 1.23 and 1.90 m/s, the estimated angle of attack of the cambered otter board was ranged between $26.1^{\circ}$ and $29.6^{\circ}$, respectively, though the maximum lift force was at the angle of attack $22.6^{\circ}$. The angle of attack of the otter board was tended to increase weakly with the longer length of warp (180 m) at the same towing speed in the experiment.

Axial Fatigue Behavior of Structural Cables (구조용 케이블의 축방향 피로거동)

  • Suh, Jeong In;Chang, Sung Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.589-600
    • /
    • 1998
  • This study was planned to verify the usefulness of Latin square design method in fatigue tests of cables and to see the axial fatigue behavior of wire ropes being used as hangers in suspension bridges. Three parameters : mean stress, stress range. and specimen length, were adopted for verification. The effects of these parameters are in argument except for stress range. Three classes in each parameter were used. Triple replication was performed in each cell to increase the number of replication (or degree of freedoms). The major cause of fatigue failure was fretting fatigue at trellis contact point. Three chosen parameters were proved to be significant. It was verified that the effect of stress range was in agreement with expectation, but the effect of specimen length was contrary to the expectation. It was also observed that the effect of mean stress depended upon the chosen level. Therefore Latin square design method is effective for verifying the parameters that affect fatigue behaviour under orthogonality conditions.

  • PDF

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

Measurement of compressive and tensile strain in concrete structure with FBG sensor fixture (광섬유격자센서의 콘크리트구조물에의 고정과 압축 및 인장 변형의 측정)

  • Kim, Ki-Soo;Kim, Young-Jin;Moon, Dae-Jung;Kim, Seong-Woon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.149-152
    • /
    • 2008
  • FBG sensor system is applied to the concrete lining structure in Taegu subway. Near the structure, the power cable tunnel construction started. We wanted to measure the deformation of the structure due to the construction by the FBG sensor. The applied sensor has the gauge length of 1 meter to overcome the inhomogeneity of the concrete material with enough length. In order to fix tightly to the structure, the partially stripped parts of the sensor glued to the package and slip phenomenon between fiber and acrylate jacket was prevented. Prestrain of the sensor was imposed by controlling the two fixed points with bolts and nuts in order to measure compressive strain as well as tensile strain. The behavior of subway lining structure could be monitored very well

  • PDF

Wind characteristics at Sutong Bridge site using 8-year field measurement data

  • Xu, Zidong;Wang, Hao;Wu, Teng;Tao, Tianyou;Mao, Jianxiao
    • Wind and Structures
    • /
    • v.25 no.2
    • /
    • pp.195-214
    • /
    • 2017
  • Full-scale wind characteristics based on the field measurements is an essential element in structural wind engineering. Statistical analysis of the wind characteristics at Sutong Cable-stayed Bridge (SCB) site is conducted in this study with the recorded long-term wind data from structural health monitoring system (SHMS) between 2008 and 2015. Both the mean and turbulent wind characteristics and power spectra are comprehensively investigated and compared with those in the current codes of practice, such as the measured wind rose diagram, monthly maximum mean wind speed, turbulence intensity, integral length scale. Measurement results based on the monitoring data show that winds surrounding the SCB site are substantially influenced by the southeast monsoon in summer and strong northern wind in winter. The measured turbulence intensity is slightly higher than the recommended values in specifications, while the measured ratio of lateral to longitudinal turbulence intensity is slightly lower. An approximately linear relationship between the measured turbulence intensities and gust factors is obtained. The mean value of the turbulence integral length scale is smaller than that of typical typhoon events. In addition, it is found that the Kaimal spectrum is suitable to be adopted as the power spectrum for longitudinal wind component at the SCB site. This contribution would provide important wind characteristic references for the wind performance evaluation of SCB and other civil infrastructures in adjacent regions.

Design and Trend Analysis According to the Application Field of Monopole Antenna with Sleeve Structure (슬리브 구조를 갖는 모노폴 안테나의 활용분야에 따른 설계와 동향분석)

  • Kang, Sang-Won;Byeon, Mi-Kyeong;Lee, Shin-Hee;Choe, Gwang-Je
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.135-141
    • /
    • 2020
  • This paper summarizes the data of a monopole antenna with a sleeve structure that can be applied in various ways. Sleeve monopole antennas have broadband characteristics and are used for multi-frequency applications. The sleeve monopole antenna is composed of a vertical conductor, which is a radiator, and a sleeve having the same structure as a coaxial cable. The sleeve acts as a radiator and an open stub. The length of the sleeve should be 1/3~2/3 of the total length of the antenna. A monopole antenna having a sleeve structure is applicable to a vehicle wiper antenna. In addition, the case of applying this antenna to a broadband sleeve antenna using a loading coil, a broadband printed sleeve monopole antenna for an ISM band, a gap sleeve and a double sleeve, and a UWB planar monopole antenna using half cutting was summarized and analyzed in terms of structure and broadband.

Prediction of load transfer depth for cost-effective design of ground anchors using FBG sensors embedded tendon and numerical analysis

  • Do, Tan Manh;Kim, Young-Sang
    • Geomechanics and Engineering
    • /
    • v.10 no.6
    • /
    • pp.737-755
    • /
    • 2016
  • The load transfer depth of a ground anchor is the minimum length required to transfer the initial prestressing to the grout column through the bonded part. A thorough understanding of the mechanism of load transfer as well as accurate prediction of the load transfer depth are essential for designing an anchorage that has an adequate factor of safety and satisfies implicit economic criteria. In the current research, experimental and numerical studies were conducted to investigate the load transfer mechanism of ground anchors based on a series of laboratory and field load tests. Optical FBG sensors embedded in the central king cable of a seven-wire strand were successfully employed to monitor the changes in tensile force and its distribution along the tendons. Moreover, results from laboratory and in-situ pullout tests were compared with those from equivalent case studies simulated using the finite difference method in the FLAC 3D program. All the results obtained from the two proposed methods were remarkably consistent with respect to the load increments. They were similar not only in trend but also in magnitude and showed more consistency at higher pullout loading stages, especially the final loading stage. Furthermore, the estimated load transfer depth demonstrated a pronounced dependency on the surrounding ground condition, being shorter in hard ground conditions and longer in weaker ones. Finally, considering the safety factor and cost-effective design, the required bonded length of a ground anchor was formulated in terms of the load transfer depth.