• Title/Summary/Keyword: cable length

Search Result 372, Processing Time 0.032 seconds

Linear and Nonlinear Wave Pressure Distributions Acting on Vertical Caisson of Large Size in 3-Dimensional Wave Fields (3차원파동장에 있어서 대형연직케이슨에 작용하는 선형 및 비선형의 파압분포특성에 관한 연구)

  • 김도삼;신동훈;이봉재
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.114-119
    • /
    • 2001
  • Goda formula (Goda, 1973) has been used in the determination of wave pressures acting on a large size caisson such as the pier of the cable stayed bridge at sea. Goda formula, however, is to evaluate the wave pressures acting the infinite vertical caisson of composite breakwater so that it can`t be applied to a large caisson with finite width and length because of diffraction effects. In the present study, three dimensional nonlinear frequence domain method based on perturbation method and boundary integral method is applied to the computation of the linear and nonlinear wave pressures acting on the front of a large size caisson under the variation of its width and length, and angle of incident wave. The numerical results are compared to Goda\`s ones, and then the characteristics of wave pressure distributions acting on a large size caisson are discussed.

  • PDF

Retrofitting Device to Increase Seismic Resistant Capactiy of Shear Walls (전단벽의 내진보강을 위한 방법에 관한 연구)

  • Hong, Sung-Gul;Lee, Ji-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.25-28
    • /
    • 2005
  • The elastic buckling load or strength of a concentrically loaded slender metal column may be increased many times by reinforcing it with an assemblage of pretensioned stays and rigidity connected crossarm members. The complete system is herein referred to as a 'stayed column'. The purpose of the pretensioned stays and crossarm members is to introduce, at several points along the length of the column, restraint against translation and rotation and thereby decrease the effective unsupported buckling length of the column. This paper verifies that pretensioned cable of stayed column is effective for cyclic load and increases strength of shear wall against earthquake by reinforcing side of wall. Design process of stayed column which satisfies demanded capacity and ductility of wall is presented by analyzing result of experiment.

  • PDF

1Monitoring system for the subway structures using pre-strain controllable FBG sensors (프리스트레인 가변형 광섬유센서를 이용한 지하철 구조 모니터링시스템)

  • Kim, Ki-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.700-709
    • /
    • 2009
  • FBG sensor system is applied to the concrete lining structure in Taegu subway. Near the structure, the power cable tunnel construction started. We wanted to measure the deformation of the structure due to the construction by the FBG sensor. The applied sensor has the gauge length of 1 meter to overcome the inhomogeneity of the concrete material with enough length. In order to fix tightly to the structure, the partially stripped parts of the sensor glued to the package and slip phenomenon between fiber and acrylate jacket was prevented. Prestrain of the sensor was imposed by controlling the two fixed points with bolts and nuts in order to measure compressive strain as well as tensile strain. The behavior of subway lining structure could be monitored very well.

  • PDF

Equilibrium shape analysis of single layer structure by measure potential function

  • Ijima, Katsushi;Xi, Wei;Goto, Shigeo
    • Structural Engineering and Mechanics
    • /
    • v.5 no.6
    • /
    • pp.775-784
    • /
    • 1997
  • A unified theory is presented for the shape analysis of curved surface with a single layer structure composed by frame, membrane or shell. The shapes produced by the theory have no shear stress in elements, and the stress states in the whole shape are as uniform as possible under an ordinary load. The theory starts from defining an element potential function expressed by the measurement of the element length or the element area. Therefore, the shape analysis can produce various forms according to the definition of the potential function, and each of those form or the cable net form with the potential function of the second power of element length is simply gotten by the linear analysis. The form in tensile stress is mechanically equal to an isotropic tension form.

Measurement and Analysis of Sheath Circulating Current in Domestic Underground Transmission Cables (국내 송전 케이블 시스 순환전류 실측 및 분석)

  • 하체웅;김정년;이수길;김동욱;이종범;강지원
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.193-200
    • /
    • 2003
  • The use of underground transmission tables has continuously increased in densely inhabited urban and suburban area. Due to a increasing demand of underground cables, two or more circuits are installed in parallel for several kilometers. It, however, has not been realized that the sheath circulating current is generated in the system where a large number of cables are laid in the same route. In this paper, Author studied diversely the sheath circulating current on underground cables depending on the various length rate, the phase arrangement, and the grounding resistance of the sheath in the cross-bonded section. It was clear that very large circulating current is generated in cable systems due to unbalanced length rate and phase arrangement in the cross-bonded section.

A Study on Behavior Analysis of Large-diameter Drilled Shaft by Design Methods in Deep Water Depth Composite Foundation (대수심 대형 복합기초에서 설계기법에 따른 대구경 현장타설말뚝의 거동 분석 연구)

  • Han, Yushik;Choi, Yongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.1
    • /
    • pp.5-16
    • /
    • 2015
  • In the long span bridge construction, construction cost portion of large scale marine foundation is about 40% (KICTEP, 2007). In this study, designs for deep water depth large composite foundation of a super long span cable-stayed girder bridge of prototype were performed by three design methods (ASD, LRFD, Eurocode) and the behaviors of a large diameter drilled shaft were analyzed and the 3D numerical analysis was performed. As a result, the soft rock socket lengths in allowable stress design estimation method were the longest. The soft rock socket lengths estimated by the design approach 2 among Eurocode and the LRFD were similar. The longer the socket length socketed in the soft rock was, the smaller the axial force acting on a large-diameter drilled shaft head was and the smaller the settlement of drilled shaft was.

Stem Effect Correction Factor of Ionization Chamber in Exposure Measurements of High Energy Photons (고 에너지 광자선의 조사선량 측정 시 전리함의 스템효과 보정계수)

  • Park, Cheol-Woo;Lee, Jae-Seung;Kweon, Dae-Chel;Cha, Dong-Soo;Kim, Jin-Soo;Kim, Kyoung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • Ionization chambers often exhibit a stem effect, caused by interactions of radiation with air near the chamber end, or with dielectric in the chamber stem or cable. In this study measured stem effect correction factor for length of ionization chamber from medical linear accelerator recommend to with the use of stem correction method. For a model of the Farmer-type chamber, were used to calculate the beam quality correction factor. These interactions contribute to the apparent measured exposure. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field. Linear accelerator generated photons energy and increased dose repeatedly measured by using stem correction method. Stem effect was dependence of the energy and increases with photon energy conditions improved of beam quality. In conclusion, stem effect correction factor was measured within 0.4% calculated according to the exposures stem length and also supposed to determined below 1% of another stem correction method.

  • PDF

Review on Underwater Positioning for Deep Towing Vehicles (심해 예인 탐사장비의 위치 보정에 대한 고찰)

  • Lee, Gun-Chang;Ko, Young-Tak;Yoo, Chan-Min;Chi, Sang-Bum;Kim, Jong-Uk;Ham, Dong-Jin
    • Ocean and Polar Research
    • /
    • v.27 no.3
    • /
    • pp.335-339
    • /
    • 2005
  • The underwater positioning system is important in interpreting data that are acquired from towing vehicles such as the deep-sea camera (DSC) system. Currently, several acoustic positioning systems such as long baseline (LBL), short baseline (SBL), and ultra short baseline (USBL), are used for underwater positioning. The accurate position of DSC, however, could not be determined in a R/V Onnuri unequipped with any of these underwater positioning systems. As an alternative, the DSC position was estimated based on the topography of towing track and cable length in the cruises before 1999. The great uncertainties, however, were found in the areas of flat bottom topography. In the 2003 and 2004 cruises these uncertainties were reduced by calculating the position of DSC with the cable length and seafloor depth below the vessel. The Japanese cruises for Mn-nodule used a similar estimation method for the DSC positioning system with a CTD sensor. Although the latter can provide better information for the position of DSC, the USBL underwater positioning system is strongly recommended for establishing better positioning of DSC and other towing devices.

The Characteristics of Residual Stand Damages Caused by Skyline Thinning Operations in Mixed Conifer Stands in South Korea

  • Han, Sang-Kyun;Cho, Min-Jae;Baek, Seung-An;Yun, Ju-Ung;Cha, Du-Song
    • Journal of Forest and Environmental Science
    • /
    • v.35 no.3
    • /
    • pp.197-204
    • /
    • 2019
  • A tree-length harvesting system using the HAM300, which is mounted on a farm tractor prototype machine, have been recently introduced in South Korea for thinning old (>30 years) forests. However, no research has previously been conducted on the characteristics of residual stand damage associated with cable yarding systems on thinning treatment stands in South Korea. Therefore, there were assessed on the degree and quantity of residual stand damage caused by felling and yarding process to broaden the knowledge of residual stand damage on semi-mechanized skyline thinning operations. This study investigated scar size, direction, area, shape type and their distribution on the residual stand damage caused by felling and yarding operations. Damage to residual trees was generated for 7.4% and 6.9% of residual trees in felling and yarding operations, respectively. Damaged direction of scars was located in front-side (38.9%) and up-side (34.7%) for felling operations while the highest scar damage was found on down-side (44.6%) for yarding operations. Scar heights of felling damage were higher than those of yarding damage. In yarding operation, the most of the scars was located within l0m from the center of the skyline corridor. These results should be useful information for forest managers and landowners to reduce residual stand damages and retain valuable timber volume from thinning treatments.

Visitors' Perceptions and Attitudes about Establishing a Cable Car in Mudeungsan Provincial Park (무등산도립공원 케이블카 설치에 대한 탐방객의 인식 및 태도)

  • Kim, Sang-Oh
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.3
    • /
    • pp.421-431
    • /
    • 2011
  • This study examined visitors' perceptions and attitudes about establishing cable car in Mudeungsan Provincial Park (MPP). Data were collected from 401 respondents by a field questionnaire survey in MPP during the September of 2010. 61.7% of respondents opposed to establishing cable car in MPP while 20.6 percent supported it. Respondents showed high level of belief to possible consequences that establishing cable car will result in 'deterioration of ecosystem and natural landscape', 'crowding problem by increased number of visitors', 'disappearance of naturalness or previous nature experiences in MPP'. Respondents, however, presented low belief to 'positive effects on increasing economic income and local economic growth by attracting tourists'. 32.4 percent of the survey respondents evaluated the present MPP as a place of 'Nature Preservation Area (NPA)' and 10.5% as 'Developed Park Area (DPA)'. 48.8% of respondents answered that MPP should be managed as 'NPA' with only 2.5% as DPA. Respondents' socio-demographic characteristics (i.e., gender, age, education level, length of residence in Gwang-ju city), use patterns (number of visits to MPP or to Jungbong and surrounding areas), and normative place condition of MPP showed relationship with the overall support rates about establishing cable car. The results and their implications were discussed.