• Title/Summary/Keyword: cable length

Search Result 372, Processing Time 0.035 seconds

Development of the compacted extra high voltage by-pass cable machinery (콤팩트화된 특고압 이동형 케이블 장치의 개발)

  • Ahn, Y.K.;Seo, S.J.;Paeck, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.268-270
    • /
    • 1991
  • In this paper, we introduce the 22.9kv by-pass cable machinery being developed. This machinery is so desinged as to solve many problems of the conventional one such as the limitation of usage, working space, route length etc. It is, so to speak, one touch-one system. Compared with the conventional system, this has several advantages, which are the cost down, the decreasing working time and space, and the multiusage etc.

  • PDF

Partial Discharges Detection for MV Cables using Non-conventional Sensors (Non-conventional 센서를 이용한 MV급 전력케이블의 부분방전 측정)

  • Kim, Jong-Yeol;Lee, Young-Jo;Cho, Sung-Joo;Nam, Jung-Hak;Koo, Ja-Yoon;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1604-1605
    • /
    • 2011
  • This paper deals with the partial discharge detection in order to recognize with three different nature of artificial defects using non-conventional HF-VHF PD sensor of which two measuring position are chosen along the 22.9kV XLPE power cable specimen. The response of the sensor under investigation has been observed be significantly affected by the cable length from the PD sources. As a result, it seems that the detecting sensor position is very important for the analysis of the nature of PD source. Moreover, it could be suggested that any standardized calibration method should be established replacing IEC 60270 as far as any type of non-conventional sensors are concerned.

  • PDF

Plan IE Design Of Extradosed Bridge Supported by Single Plane Cables (일면지지식 Extradosed교의 계획 및 설계)

  • 이종대;이두화;권소진;김종수;손준상
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.615-620
    • /
    • 2001
  • The aim of this paper is to open up a relatively new type in bridge engineering by introducing plan and design of extradosed bridge which is implemented in Sungnam-Janghowon T/K project. The topic encompasses parametric study including the behavior of the bridge relevant to the cable layout, the distance from pier table to the first cable's location, the height of pylon, the stiffness of cross section and wind vibration to ascertain sectional type of bridge and span length. For the purpose of the knowledge base presented here, the important feature of design is recommended such as modeling method, camber control, finite element analysis and heat hydration of pier table. We can verify the issue related to the characteristics of extradosed bridge as a result of study and design endeavor.

  • PDF

Development of a Remote Inspection Method and Device for Line Sleeves on Transmission Line (송전선로 직선슬리브 원격점검 방법 및 장치)

  • Lee, Jae-Kyung;Jung, Nam-Joon;Kim, Ho-Ki;Kim, Kyeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.206-213
    • /
    • 2011
  • Line sleeves, which used to connect ACSR cables when transmission lines were constructing, sometimes cause power transmission failure due to deterioration and corrosion. Therefore, power transmission line should be inspected regularly to prevent national disaster. Current inspection tool detects insertion length of transmission line on line sleeves, the inspection tool includes enormous error by operator. Moreover, the system is not controlled remotely, negligent accident would be caused while inspecting. To deal with those problems, KEPCO reviewed several ways to inspect line sleeves and proposes new method to inspect line sleeve by measuring magnetic flex which penetrate junction of steel and aluminum sleeve. The developed inspection tool is reliable enough to detect eccentric sleeves. Also, the developed inspection device was applied on actual transmission line and verified its effectiveness.

An Estimating Mehod of the Angle of Attack of a Vertical V-type Otter Board (종만곡 V형 전개판의 영각 추정법)

  • Park, Hae-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.2
    • /
    • pp.113-121
    • /
    • 2005
  • How to extimate the angle of attack of a vertical V-type cambered otter board was described. A three-dimensional semi-analytic treatment of a towing cable system was applied to the field experiments of a midwater trawl obtained by the Scanmar system. Also the equilibrium condition of the horizontal component and vertical component of forces and moment around the otter board was used. When the warp length was 300m long and the towing speed was between 2.61 and 3.86 knots, the estimated angle of attack of the otter board was ranged between $24.7^{\circ}$ and $26.2^{\circ}$, though the maximum lift force was at the angle of attack $22^{\circ}$.

Fabrication and properties of 500A class multistrand conductor for HTS power cable (고온초전도 전력케이블용 500A급 코어 도체 제조 및 특성실험)

  • Yoo, Jai-Moo;Park, Sung-Chang;Ko, Jae-Woong;Kim, Hai-Doo;Chung, Hyung-Sik
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.334-337
    • /
    • 1999
  • High T$_c$ (${\sim}$21,500 A/cm$^2$, at 77K) of 100m length of BSCCO 2223 tapes have been achieved using optimized precursor powders with carefully controlling variables in heat treatment. Prototype 500A class multistrand conductor for HTS power cable was fabricated using these tapes. Also discussed are the transportation properties of prototype 500A class multistrand conductor.

  • PDF

장파장 다중모드 광섬유 통신시스템의 실용시험

  • Kim, Yong-Hwan;Lee, Seong-Eun;Kim, Hong-Man;Park, Chang-Su;Won, Yong-Hyeop;An, Jong-Pyeong;Yu, Tae-Hwan;Sin, Dong-Hyeok;Seo, Wan-Seok;Gang, Min-Ho
    • ETRI Journal
    • /
    • v.6 no.2
    • /
    • pp.15-17
    • /
    • 1984
  • A long-wavelength ($1. 3\mum$) multimode fiber-optic transmission system has been developed and the field trial system has been installed over 17.3km distance in Daejeon Area by KETRI. The 45Mb/s and 90Mb/s system operate with BER $10^-9$over 17.3km distance, and they successfully operate on the route of 34. 6km length when the fiber cable is simply connected at one end. Average loss of the fiber cable shows 0. 81dB/km including splice loss and the average bandwidth over the 17. 3km distance is 170MHz.

  • PDF

Analysis of Sheath Circulating Current in Underground Transmission Power Cables according to Unbalanced Factor (불평형 요소 변화에 따른 지중 송전선로의 시스순환전류 분석)

  • Choi, Soo-Hyun;Kim, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.294-295
    • /
    • 2015
  • Many unbalanced factors of underground transmission power cable, such as burying types and the length difference of the cable between each minor section, etc will cause the impedance unbalance and excessive circulating current between cables. So this paper presents the analysis of sheath circulating current in accordance with the distance between the center conductors and phase arrangement. ground resistance value changes on 154kV transmission system. Based on these simulation results, this paper will contribute to the reduction method of sheath circulation current.

  • PDF

Anormal Dielectric and Insulation Properties of Semiconductor/XLPE (반도전층/XLPE 의 불규칙한 유전 및 절연 특성)

  • Lee, Jong-Chan;Kim, Kwang-Soo;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.53-57
    • /
    • 2002
  • Reduction of insulation thickness would be beneficial not only for increasing the cable length but would also improve its thermal performance. An interfacial diffusion method was devised to reduce insulation thickness by improving the interfacial properties of XLPE cable insulation. In this paper, to evaluate superficially the interface properties between XLPE insulation and semiconducting layer, the dielectric and insulation properties of tan${\delta}$ and volume resistance were measured with temperature dependence. Above the results, dielectirc and insulation properties with semiconductor/XLPE were more anormal than its bulk caused by the interfacial properties.

  • PDF

Igniter design methods of the ballasts for Ceramic Metal Halide lamp (세라믹 메탈할라이드 램프용 안정기의 점화기 설계 방법)

  • Park, Chong-Yeun;Choe, Wang-Seop
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.75-81
    • /
    • 2010
  • We described the operating principles of two different type of igniters for lightning of Ceramic Metal Halide Lamp(CMHL) and also provide some useful comparisons. One is for magnetic ballast, the other one is for electronic ballast which operates lamp by low-frequency square-waveform. Ignition voltage of lamp depends on the structure of igniter, such as the length and electrical characteristics of cable, which make troubles for ignition in real sites. Therefore, we measured and analyzed ignition voltages from igniters which are used in magnetic and electronic ballast in cables at a distance of 5 meters between a lamp and a igniter to suggests an applicable solution in real sites.

  • PDF