• 제목/요약/키워드: cQA

검색결과 56건 처리시간 0.022초

Study on Highly Accuracy Quality Evaluation of Spot Weld by use of Image Processing Technique

    • 한국생산제조학회지
    • /
    • 제5권4호
    • /
    • pp.38-46
    • /
    • 1996
  • This paper discusses the feasibility of Ultrasonic Nondestructive Evaluation (UNDE) technique for sport weld quality. Ultrasonic c-scan image assisted by image processing technique was used for Nondestructive Evaluation(NDE) of spot weld quality. Ultrasonic testing results obtained were confirmed and compared by Optical Microscope and SAM(Scanning Acoustic Mircroscope) observation of the spot-weld cross section, The results show that the nugget dinameter can be successfully measured with the accuracy of 0.5mm. It was ascertained that ultrasonic c-scan technique is very effective method for the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget. Additional support for the above conclusions is provided by the results for galvanized steel. The ultrasonic results for galvanized welds generally correspond to the results for uncoated steel. Finally, it was found that the above-mentioned technique can be sufficiently applied to NDE method for securing the Quality Assurance(QA) of spot welded products in production line.

  • PDF

LOCAL SPECTRAL THEORY II

  • YOO, JONG-KWANG
    • Journal of applied mathematics & informatics
    • /
    • 제39권3_4호
    • /
    • pp.487-496
    • /
    • 2021
  • In this paper we show that if A ∈ L(X) and B ∈ L(Y), X and Y complex Banach spaces, then A ⊕ B ∈ L(X ⊕ Y) is subscalar if and only if both A and B are subscalar. We also prove that if A, Q ∈ L(X) satisfies AQ = QA and Qp = 0 for some nonnegative integer p, then A has property (C) (resp. property (𝛽)) if and only if so does A + Q (resp. property (𝛽)). Finally, we show that A ∈ L(X, Y) and B, C ∈ L(Y, X) satisfying operator equation ABA = ACA and BA ∈ L(X) is subscalar with property (𝛿) then both Lat(BA) and Lat(AC) are non-trivial.

EPID의 적정관리 도구로서의 유용성에 관한 연구 (The useage of the EPID as a QA tools)

  • 조정희;방동완;윤성익;박재일
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

Effect of Parthenogenetic Mouse Embryonic Stem Cell (PmES) in the Mouse Model of Huntington′s Disease

  • 이창현;김용식;이영재;김은영;길광수;정길생;박세필;임진호
    • 한국동물번식학회:학술대회논문집
    • /
    • 한국동물번식학회 2003년도 학술발표대회 발표논문초록집
    • /
    • pp.80-80
    • /
    • 2003
  • Huntington's disease (HD) is an autosomal dominant neurodegenerative disorder characterized by motor, cognitive, and psychiatric symptoms, accompanied by marked cell death in the striatum and cortex. Stereotaxic injection of quinolinic acid (QA) into striatum results in a degeneration of GABAergic neurons and exhibits abnormal motor behaviors typical of the illness. The objective of this study was carried out to obtain basic information about whether parthenogenetic mouse embryonic stem (PmES) cells are suitable for cell replacement therapy of HD. To establish PmES cell lines, hybrid F1 (C57BL/6xCBA/N) mouse oocytes were treated with 7% ethanol for 5 min and cytochalasin-B for 4 hr to initiate spontaneous cleavage. Thus established PmES cells were induced to differentiate using bFGF (20ng/ml) followed by selection of neuronal precursor cells for 8 days in N2 medium. After selection, cells were expanded at the presence of bFGF (20 ng/ml) for another 6 days, then a final differentiation step in N2 medium for 7 days. To establish recipient animal models of HD, young adult mice (7 weeks age ICR mice) were lesioned unilaterally with a stereotaxic injection of QA (60 nM) into the striatum and the rotational behavior of the animals was tested using apomorphine (0.1mg/kg, IP) 7 days after the induction of lesion. Animals rotating more than 120 turns per hour were selected and the differentiated PmES cells (1$\times$10$^4$cells/ul) were implanted into striatum. Four weeks after the graft, immunohistochemical studies revealed the presence of cells reactive to anti-NeuN antibody. However, only a slight improvement of motor behavior was observed. By Nissl staining, cell mass resembling tumor was found at the graft site and near cortex which may explain the slight behavioral improvement. Detailed experiment on cell viability, differentiation and migration explanted in vivo is currently being studied.

  • PDF

MLC leakage를 이용할 Verification의 효용성 고찰 (Verification of set-up accuracy using MLC leakage)

  • 윤인하;홍동기;정왕권;서동린;윤화룡;김정만
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.11-19
    • /
    • 2004
  • 서론 및 목적 : 세기변조 방사선치료와 전신 정위적 방사선치료에서 5mm이내의 위치 정확성확인 (L-gram)은 환자치료 목적 달성을 위한 중요한 QA과정의 하나이다. 이에 본원에서 제작한 scale point를 이용하여 L-gram 영상을 얻어 환자치료의 정확성을 향상시키고자 한다. 대상 및 방법 : 본원의 MLC 부착장비인 CL2100C/D, CL21EX에서 치료중인 IMRT, SRS환자를 대상으로 기존의 상품화된 port film graticule과 본원에서 제작한 MLC scale pointer를 비교 분석하였다. 결과 : MLC를 이용한 scale pointer는 beam의 확산까지 고려한 정확한 위치를 나타내었고 MLC의 교차로 생기는 pixel 모양의 형성을 통해 어떠한 위치에서도 정확한 확인이 가능했다. 결론 및 고찰 : L-gram 확인시 약간의 시간적 투자($1{\sim}2$분)로서 정확한 위치를 나타냄으로서 L-gram 확인시간 단축과 치료부위의 정확한 위치 확인을 할 수 있었다.

  • PDF

콩우유와 우유 혼합유의 단백질 안정성에 미치는 영향인자 (Factors Affecting on Protein Stability of Mixed Cow and Soy Milk)

  • 정남용;김우정
    • 한국식품영양학회지
    • /
    • 제7권4호
    • /
    • pp.345-352
    • /
    • 1994
  • High protein beverage of cow-soy milk was prepared by mixing the soymilk and commercial homogenized cow milk in the various ratios. Effect of heat treatment, pH and addition of calcium and sucrose was studied on the water-soluble nitrogen of cow-soy milk The heat-treated soymilk at 10$0^{\circ}C$ were centrifuged at the range of 830~29,900xg for 30 min and 11,200xg was found to be proper for determination of the degree of protein denaturation by centrifugal method. When soymilk was heated at 70~10$0^{\circ}C$ for 30~240 min, soluble nitrogen (QA SN) in supernatant of protein was decreased to 78.0~56.8% due to protein denaturation. Most of heat denaturation of protein was found to be occurred during Initial heating 10$0^{\circ}C$ for all mixed cow-soy milk. The sedimentation of SN was maximum at pH 4.0 In the range of pH 3~8. Addition of sucrose affected little on oASN while calcium addition reduced %SN significantly to approx. 55% for soymilk(100%). The effect of Ca was less as the ratio of cow milk increased.

  • PDF

PM2.5 자동측정장비 비교 및 정도관리 방안 (Comparison of the Real-time Measurements for PM2.5 and Quality Control Method)

  • 박미경;박진수;조미라;이용환;김현재;오준;최진수;안준영;홍유덕
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).

컴퓨터 단층촬영, 자기공명영상, 뇌혈관촬영을 이용한 정위적 수술시스템의 개발 (Development of Stereotactic Surgery system with CT, MR Imaging, and Angiography)

  • 김성현;서태석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.117-118
    • /
    • 1998
  • The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using CT/MRI/angiography and multi-purpose QA phantom. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed, and targets on each CT image were superimposed each other on MR/angiography images without distortion corretion. This system was implented in Visual C++ as a PC-based application program.

  • PDF

인공심장박동기가 이식된 유방암환자의 방사선 치료에 대한 사례 보고 (Case Report of Radiotherapy to a Breast Cancer Patient with a Pacemaker)

  • 채승훈;박장필;이양훈;유숙현;성원모;김규보
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.197-203
    • /
    • 2012
  • 목 적: 본원을 내원한 인공심장박동기를 이식한 유방암 환자에 대해 장비위치이전수술, 차폐 또는 빔 정형 등을 고려하여 방사선치료를 시행한 사례의 전반적인 과정을 고찰해보고자 한다. 대상 및 방법: 본원을 내원한 유방암환자 중 좌측 흉부에 인공심장박동기를 이식한 54세 여성 환자를 대상으로 방사선치료를 시행하였다. 환자의 방사선치료 시행이 결정된 후, 인공심장박동기로의 선량 유입을 최소화하기 위해 순환기내과와의 협의를 통해 환자 좌측 흉부에 이식되어있던 기기를 우측 흉부로 이동시키는 수술을 시행하였다. 총 선량 5,040 cGy, 일일선량 180 cGy, 28회, 치료 조건으로 광자선 에너지 10 MV, 조사야 크기 0/$9.5{\times}20$ cm를 사용하여 Half beam 대향이문조사치료를 시행하기 위한 방사선치료계획을 하였다. 방사선 치료계획 시 적합한 차폐체의 두께를 정하기 위하여 Solid water phantom($30{\times}30{\times}7$ cm)에 Farmer-type chamber (TN30013, PTW, Germany)를 이용해 차폐체(납, Pb $28{\times}27{\times}0.1$ cm)를 사용하였을 경우와 사용하지 않았을 경우 기기에 유입될 예상선량을 산출하였다. 전산화치료계획장비(Eclipse, Varian, USA)를 사용해 치료계획을 시행하고, 두께 2 mm의 차폐체를 사용하였을 경우와 사용하지 않았을 경우에 기기에 유입될 예상선량을 산출해내었다. 치료 첫 날, MOSFET Dose Verification System (TN-RD-70-W, Medical Canada Ltd., Canada)을 이용하여 인공심장박동기에 유입되는 선량을 측정하였다. 결 과: 차폐체 두께산정 실험에서 인공심장박동기가 위치한 B 지점에서 차폐체 2 mm일 경우, 105.265 cGy, 처방선량의 2.09%로 산출되어, 적합한 차폐체의 두께를 정할 수 있었다. 전산화치료계획장비에서 2 mm 차폐 시 총 치료기간 동안 11.5에서 38.2 cGy까지 기기에 유입될 수 있음이 나타났으며, DVH 최대값은 77.3 cGy로 나타났다. 환자의 첫 치료 시 MOSFET 측정 결과 4.3 cGy로 측정되어, 총 치료기간동안 120.4 cGy, 처방선량의 2.39%의 선량이 유입될 것으로 예상되었다. 환자는 치료기간동안 그리고 치료받은 후 어떠한 부작용도 일으키지 않았으며, 인공심장박동기는 치료시작 전과 후에 순환기내과에서 기능측정을 받은 결과 아무런 이상을 보이지 않았다. 결 론: 현재 인공심장박동기가 이식된 암 환자의 방사선 치료에 대한 공신력 있는 기관의 권고안이 노후화되어, 새로운 장비들에 대한 데이터가 부족한 상황에서 우리는 타과와 원활한 협업, 철저한 치료계획과 정밀한 QA, 지속적인 in-vivo dosimetry와 monitoring 등을 통하여 이러한 환자들의 방사선치료를 성공적으로 해낼 수 있을 것으로 사료된다.

  • PDF

CT 영상을 이용한 불균질 조직의 선량보정 평가 (Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image)

  • 김가중
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.75-80
    • /
    • 2006
  • 목 적: 방사선치료에 있어 종양조직이나 정상조직의 정확한 선량계산은 치료의 성패를 좌우하는 가장 큰 요인이다. 이로 인해 방사선치료계획은 컴퓨터 단층 영상의 재구성을 통한 불균질 조직에 선흡수계수를 밀도로 변환하여 CT 번호에 의한 선량 보정이 유효하게 이루어지고 있다. 대상 및 방법: 이에 본 연구는 불균질 조직등가 팬톰을 제작하여 현재 사용 중인 방사선 치료 계획시스템을 이용한 CT 번호의 측정과 질량밀도를 계산하여 물을 기준으로 상대값을 구하였다. 또한 실제 방사선 조사 시 측정된 선량(nC)과 CT영상을 이용한 치료계획 시 선량(PDD)을 상대적으로 비교함으로써 실제 CT 번호를 이용한 불균질 조직의 보정에 대한 유용성과 정확성을 평가하고자 한다. 결 과: 측정결과 CT 번호를 이용하여 계산된 조직등가물질의 질량밀도와 실제 질량밀도는 $0.005{\sim}0.069g/cm^3$의 차이를 보였으며, 방사선 치료계획 시 심부선량(PDD)과 방사선 치료 장치로 조사하여 측정된 선량의 상대오차는 $-2.8{\sim}+1.06%$로 3% 이내의 유효범위이내의 결과를 얻었다. 결 론: 본 실험은 CT 영상을 이용한 불균질 조직의 보정에 대한 유용성을 확인할 수 있었고, 방사선 치료 계획 장치의 정도 관리(Quality Assurance; QA)의 기본 틀을 제공할 수 있을 것으로 사료된다.

  • PDF