• Title/Summary/Keyword: bypass model

Search Result 165, Processing Time 0.024 seconds

A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting (착상을 수반한 멀티 가변속 열펌프의 동특성)

  • ;;Shigeru Koyama
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.

Three-dimensional Fluid Flow Analysis in Taylor Reactor Using Computational Fluid Dynamics (CFD를 이용한 테일러 반응기의 3차원 유동해석)

  • Kwon, Seong Ye;Lee, Seung-Ho;Jeon, Dong Hyup
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.448-453
    • /
    • 2017
  • We conducted the three-dimensional fluid flow analysis in a Taylor reactor using computational fluid dynamics (CFD). The Taylor flow can be categorized into five regions according to Reynolds number, i.e., circular Couette flow (CCF), Taylor vortex flow (TVF), wavy vortex flow (WVF), modulated wavy vortex flow (MWVF), and turbulent Taylor vortex flow (TTVF), and we investigated the flow characteristics at each region. For each region, the shape, number and length of vortices were different and they influenced on the bypass flow. As a result, the Taylor vortex was found at TVF, WVF, MWVF and TTVF regions. The highest number of Taylor vortex was observed at TVF region, while the lowest at TTVF region. The numerical model was validated by comparing with the experimental data and the simulation results were in good agreement with the experimental data.

RTD Analysis using Radioisotope Tracer on the Water Flow Characteristics in a Flocculator of Wastewater Treatment Facility (방사성동위원소 추적자를 이용한 폐수처리시설의 응집조에서 유입수의 체류시간분포 분석)

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Using In-113m emitting gamma ray of 0.392MeV at radioisotope tracer the RTD (residence time distribution) of water in the flocculator of wastewater treatment facility was measured. The result was analyzed mathematically using K-RTD program constructed on the basis of CFSTR (constant flow stirred tank reactor) model. The mean residence time and the tank number are the main parameters which describe the flow behavior of the system. Those parameters were obtained in the fitting profess of the simulated curves to the experimental results. It was suggested to construct a modified numerical model to describe the bypass flow which was observed in the experiment.

The Impact of an Attending Intensivist on the Clinical Outcomes of Patients Admitted to the Cardiac Surgical Intensive Care Unit after Coronary Artery Bypass Grafting

  • Kim, Dong Jung;Sohn, Bongyeon;Kim, Hakju;Chang, Hyoung Woo;Lee, Jae Hang;Kim, Jun Sung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.53 no.1
    • /
    • pp.8-15
    • /
    • 2020
  • Background: We aimed to investigate the associations of critical care provided in a cardiac surgical intensive care unit (CSICU) staffed by an attending intensivist with improvements in intensive care unit (ICU) quality and reductions in postoperative complications. Methods: Patients who underwent elective isolated coronary artery bypass grafting (CABG) between January 2007 and December 2012 (the control group) were propensity-matched (1:1) to CABG patients between January 2013 and June 2018 (the intensivist group). Results: Using propensity score matching, 302 patients were extracted from each group. The proportion of patients with at least 1 postoperative complication was significantly lower in the intensivist group than in the control group (17.2% vs. 28.5%, p=0.001). In the intensivist group, the duration of mechanical ventilation (6.4±13.7 hours vs. 13.7±49.3 hours, p=0.013) and length of ICU stay (28.7±33.9 hours vs. 41.7±90.4 hours, p=0.018) were significantly shorter than in the control group. The proportions of patients with prolonged mechanical ventilation (2.3% vs. 7.6%, p=0.006), delirium (1.3% vs. 6.3%, p=0.003) and acute kidney injury (1.3% vs. 5.3%, p=0.012) were significantly lower in the intensivist group than in the control group. Conclusion: A transition from an open ICU model with trainee coverage to a closed ICU model with attending intensivist coverage can be expected to yield improvements in CSICU quality and reductions in postoperative complications.

Does performing high- or low-risk coronary artery bypass graft surgery bias the assessment of risk-adjusted mortality rates of hospitals? (관상동맥우회로술의 위험 수준이 병원내사망률 평가 결과에 미친 영향 분석)

  • Lee, Kwang-Soo;Lee, Sang-Il;Lee, Jung-Soo
    • Health Policy and Management
    • /
    • v.17 no.3
    • /
    • pp.87-105
    • /
    • 2007
  • The purpose of this study was to analyze whether nonemergency, isolated coronary artery bypass graft (CABG) surgery for high- or low-risk patients biases the assessment of the risk-adjusted mortality rates of hospitals. This study used 2002 National Health Insurance claims data for tertiary hospitals in Korea. The study sample consisted of 1,959 patients from 23 tertiary hospitals. The risk-adjustment model used the patients' biological, admission, and comorbidity data identified in the claims. The subjects were classified into high- and low-risk groups based on predicted surgical risk. The crude mortality rates and risk-adjusted mortality rates for low-risk, high-risk, and all patients in a hospital were compared based on the rank and the four intervals defined by quartile. Also, the crude mortality rates of the three groups were compared with their 95% confidence intervals of predicted mortality rates. The C-statistic (0.83) and Hosmer-Lemeshow test ($X^2$=11.47, p=0.18) indicated that the risk-adjustment model performed well. Presenting crude mortality rates with their 95% confidence intervals of predicted rates showed higher agreements among the three groups than using the rank or intervals of mortality rates defined by quartile in the hospital performance assessment. The crude mortality rates for the low-risk patients in 21 of the 23 hospitals were located on the same side of their 95% confidence intervals compared to that for all patients. High-risk patients and all patients differed at only one hospital. In conclusion, the impact of risk selection by hospital on the assessment results was the smallest when comparing the crude inpatient mortality rates of CABG patients with the 95% confidence intervals of predicted mortality rates. Given the increasing importance of quality improvements in Korean health policy, it will be necessary to use the appropriate method of releasing the hospital performance data to the public to minimize any unwanted impact such as risk-based hospital selection.

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.

A study on Stage-Based Flow Graph Model for Expressing Cyber Attack Train Scenarios (사이버 공격 훈련 시나리오 표현을 위한 Stage 기반 플로우 그래프 모델 연구)

  • Kim, Moon-Sun;Lee, Man-Hee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.31 no.5
    • /
    • pp.1021-1030
    • /
    • 2021
  • This paper proposes S-CAFG(Stage-based Cyber Attack Flow Graph), a model for effectively describing training scenarios that simulate modern complex cyber attacks. On top of existing graph and tree models, we add a stage node to model more complex scenarios. In order to evaluate the proposed model, we create a complicated scenario and compare how the previous models and S-CAFG express the scenario. As a result, we confirm that S-CAFG can effectively describe various attack scenarios such as simultaneous attacks, additional attacks, and bypass path selection.

Temperature Control of Ultrasupercritical Once-through Boiler-turbine System Using Multi-input Multi-output Dynamic Matrix Control

  • Moon, Un-Chul;Kim, Woo-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.423-430
    • /
    • 2011
  • Multi-input multi-output (MIMO) dynamic matrix control (DMC) technique is applied to control steam temperatures in a large-scale ultrasupercritical once-through boiler-turbine system. Specifically, four output variables (i.e., outlet temperatures of platen superheater, finish superheater, primary reheater, and finish reheater) are controlled using four input variables (i.e., two spray valves, bypass valve, and damper). The step-response matrix for the MIMO DMC is constructed using the four input and the four output variables. Online optimization is performed for the MIMO DMC using the model predictive control technique. The MIMO DMC controller is implemented in a full-scope power plant simulator with satisfactory performance.

An Accelerated Life Test of Booster Pump for Water Purifier (정수기용 부스터펌프의 가속수명시험)

  • Moon, Ji-Seob;Jeong, Seon-Yong;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2011
  • This paper presents an accelerated life test of booster pump for home water purifier. The failure analysis shows that decreased flux due to the plastic deformation of bypass spring adjusting pressure is the predominant failure mechanism. An accelerated life test is designed and implemented to estimate the lifetime of the booster pump. Temperature, water pressure and voltage are selected as accelerating variables through the technical review about failure mechanism. It is assumed that the lifetimes of booster pumps follow lognormal distribution and the combination model of temperature and non-thermal stresses holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.