• Title/Summary/Keyword: bypass flow

Search Result 326, Processing Time 0.028 seconds

Application of Bypass Flow for Improving Performance of the Vertical Column Pneumatic Separator (수직(垂直)컬럼형(形) 풍력선별기(風力選別機)의 분리효율향상(分離效率向上)을 위한 bypass유로(流路)의 적용(適用))

  • Lee, Gye-Seung;Song, Young Jun;Yotsumoto, Hiroki
    • Resources Recycling
    • /
    • v.22 no.3
    • /
    • pp.65-72
    • /
    • 2013
  • A vertical column pneumatic separator was modified to improve its separation performance. A branch column was installed at the center of the main column, which created a bypass flow and changed the flow rate of the main column before and after the branch column. To separate a mixture comprising light and heavy materials, the airflow in main column after the branch column was set to lift the only light materials and the airflow in main column before the branch column was set to prevent the flow of the light materials from flowing downwards. Materials directed into the branch column were separated from the flow and returned to the feeder through the cyclone linked to the branch column. The performances of the straight-type separator and the modified separator were compared using glass and zirconia beads with a narrow size distribution.

Establishment of Featal Heart Surgery with an Improvement of the Placental Blood Flow in Cardiopulmonary Bypass Using Fetal Lamb Model (양태아를 이용한 심폐우회술에서의 태반혈류개선을 통한 태아심장수술의 기반기술 확립)

  • 이정렬;박천수;임홍국;배은정;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • Background: We tested the effect of indomethacine and total spinal anesthesia on the improvement of placental flow during cardiopulmonary bypass on fetal lamb. Material and Method: Twenty fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Ten served as a control group in which placenta was worked as an oxygenator during bypass (Control group). The remainder worked as an experimental group in which pretreatment with indomethacine and total spinal anesthesia was performed before bypass with the same extracorporeal circulation technique as control group (Experimental group). Observations were made every 10 minutes during a 30-minute bypass and 30-minute post bypass period. Result: Weights of the fetuses ranged from 2.2 to 5.2 kg. In Control group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of Pa$CO_2$ increased from 61.9 to 129.6 mmHg at each time points during bypass. Flow rate was suboptimal (74.3 to 97.0 $m\ell$/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. On the contrary, in Experimental group, means of arterial pressure reamined higher (45.8 to 30 mmHg) during bypass (p<0.05). Means of Pa$CO_2$ were less ranging from 59.8 to 79.4 mmHg during bypass (P<0.05). Flow rates were higher (78.8 to 120.2 $m\ell$/kg/min) during bypass (p<0.05). There were slower deterioration of cardiac function after cessation of bypass. Conclusion: In this study, we demonstrated that the placental flow was increased during fetal cardiopulmonary bypass in the group pretreated with indomethacine and total spinal anesthesia. However, further studies with modifications of the bypass including a creation of more concise bypass circuit, and a use of axial pump are mandatory for the clinical application.

The Change of Derum and Urine Amylase Level Following Cardiopulmonary Bypass in the Patients with Congenital heart disease (선천성 심기형 환아에서 체외순환후 혈청 및 소변 Amylase치의 변화)

  • Baek, Hui-Jong;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.28 no.10
    • /
    • pp.892-899
    • /
    • 1995
  • Pancreatitis is a known complication of cardiac surgery with cardiopulmonary bypass. Although ischemia is believed to be a factor, the exact cause of pancreatitis after cardiopulmonary bypass remains unknown.We prospectively studied 67 consecutive patients undergoing cardiac surgery with cardiopulmonary bypass for evaluation of the pancreatic injury after cardiopulmonary bypas. Serial measurement of amylase level in serum and urine was done postoperatively. Hyperamylasemia was detected in 15 patients[22.4% , of whom no patient had pancreatitis. There was no significant difference between serum amylase level and parameters such as cardiopulmonay bypass time, aortic cross clamp time, mean blood pressure, rectal temperature, flow rate, and use of circulatory arrest during cardiopulmonary bypass. Hyperamylasuria was detected in 8 patients[11.9% , and urine amylase level was elevated significantly in the groups with prolonged cardiopulmonary bypass, mean blood pressure more than 40mmHg, and rectal temperature more than 20 $^{\circ}$C. We recommend that serum amylase level and/or amylase-creatinine clearance ratio is measured for ealy detection and management of pancreatitis after cardiopulmonary bypass.

  • PDF

Analysis of Flow through High Pressure Bypass Valve in Power Plant (발전소용 고압 바이패스 밸브의 유동해석)

  • Cho, An-Tae;Kim, Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2558-2562
    • /
    • 2007
  • In the present work, flow characteristics analysis has been performed for steam turbine bypass control valve (single-path type). The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. Shear stress transport (SST) model is used as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. Mass flow rate at maximum plug opening condition is compared with the designed mass flow rate.

  • PDF

Computational modeling of the coronary circulation for the assessment of the coronary artery bypass through left ventricle (좌심실을 통한 관상동맥 우회술의 평가를 위한 관상순환계의 수치적 모델)

  • Shim, Eun-Bo;Kamm, Roger D.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.385-390
    • /
    • 2000
  • In this study we propose the computational model for the coronary circulation. The bypass from left ventricle is also considered. Lumped parameter model with three compartments in the coronary circulation is implemented in this study. We connected the coronary artery compartment with left ventricle to explain the bypass procedure from left ventricle. The asymmetric resistance is assumed in the bypass line from left ventricle. The present numerical method is tested for normal coronary circulation and the results are compared with the existing computational work. The bypass simulation is conducted and the flow pattern is delineated. The effect of shunt resistance and coronary compliance to circulation is investigated for the better design of the bypass shunt.

  • PDF

Experimental and Numerical Analyses of flow field in a bypass valve (바이패스밸브 유동장에 관한 실험 및 수치해석)

  • Choi, Ji-Yong;Cho, An-Tae;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.527-530
    • /
    • 2006
  • In the present work, characteristics of the flow in the cage of a steam turbine bypass control valve for thermal power plant are investigated. Experimental measurement for wall static pressure has been carried out to validate numerical solutions. And, the flowfield is analyzed by solving steady three-dimensional Reynolds-averaged Navier-Stokes equations. Shear stress transport (SST) model is used as turbulence closure. The effects of the flow area between stages of the cage on the pressure drop are also found.

  • PDF

Analysis of Flow Field in a Steam Turbine Bypass Valve (증기터빈 바이패스밸브 케이지 유동장 해석관한 연구)

  • Choi Ji-Yong;Cho An-Tai;Kim Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.36-42
    • /
    • 2006
  • In the present work, characteristics of the flow in the cage of a steam turbine bypass control valve for thermal power plant are investigated. Experimental measurement for wall static pressure has been carried out to validate numerical solutions. And, the flowfield is analyzed by solving steady three-dimensional Reynolds-averaged Navier-Stokes equations. Shear stress transport (SST) model is used as turbulence closure. The effects of the flow area between stages of the cage on the pressure drop are also found.

Aircraft Engine Performance Test Technologies by 150K lbf Thrust Test Cell (15만 파운드급 테스트 셀을 이용한 엔진성능 시험기술)

  • Kim, Woocheol;Kim, Chul;Kim, Sangbaek
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.180-187
    • /
    • 2017
  • Major design targets such as test cell type, cell flow, cell bypass ratio, approach velocity, cell depression, front cell distortion, noise level and vibration level to construct a new 150,000 lbf thrust aircraft engine test facility were established. Based on the final aerodynamic and acoustic performance tests conducted at the newly constructed test facility, it was found that the new test facility is judged to be excellent and meets design targets.

  • PDF

Numerical Analysis for Internal Leakage Flow Characteristics of Damped Bypass Valve (Damped Bypass Valve의 내부 누설 유동 특성 전산 해석)

  • Lee, Seawook;Kim, Daehyun;Kim, Sangbeom;Park, Sangjoon;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • A numerical analysis for the internal flow was carried out in order to analyze the leakage flow characteristics inside the damped bypass valve. This research has found that the valve characteristics became stable at above a specific temperature. Very small amount of leakage flow was occurred. But there was no effect in temperature. The more temperature fell, the more maximum pressure rate was increased.