• Title/Summary/Keyword: bypass

Search Result 2,120, Processing Time 0.036 seconds

Analysis on thermal & electrical characteristics variation of PV module with damaged bypass diodes (PV 모듈 내 바이패스 다이오드 손상에 의한 열적 전기적 특성 변화 분석)

  • Shin, Woo-Gyun;Jung, Tae-Hee;Go, Seok-Hwan;Ju, Young-Chul;Chang, Hyo-Sik;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.67-75
    • /
    • 2015
  • PV module is conventionally connected in series with some solar cell to adjust the output of module. Some bypass diodes in module are installed to prevent module from hot spot and mismatch power loss. However, bypass diode in module exposed outdoor is easily damaged by surge voltage. In this paper, we study the thermal and electrical characteristics change of module with damaged bypass diode to easily find module with damaged bypass diode in photovoltaic system consisting of many modules. Firstly, the temperature change of bypass diode is measured according to forward and reverse bias current flowing through bypass diode. The maximum surface temperature of damaged bypass diode applied reverse bias is higher than that of normal bypass diode despite flowing equal current. Also, the output change of module with and without damaged bypass diode is observed. The output of module with damaged bypass diode is proportionally reduced by the total number of connected solar cells per one bypass diode. Lastly, the distribution temperature of module with damaged bypass diode is confirmed by IR camera. Temperature of all solar cells connected with damaged bypass diode rises and even hot spot of some solar cells is observed. We confirm that damaged bypass diodes in module lead to power drop of module, temperature rise of module and temperature rise of bypass diode. Those results are used to find module with a damaged bypass diode in system.

"Off-Pump" Coronary rtery bypass Grafting in Multi-vessel Coronary Disease -Two Cases- (다중 혈관질환에서 심폐바이패스를 이용하지 않은 관상동맥 우회술)

  • 유원희;김기봉
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1123-1126
    • /
    • 1999
  • Coronary artery bypass grafting (CABG) technique has been much developed but CABG under cardiopulmonary bypass has the unavoidable deficits such as generalized inflammatory reaction from cardiopulmonary bypass and myocardial ischemia from aortic-cross clamp. There has been remarkable advancement of CABG without cadiopulmonary bypass. We performed CABG successfully without cardiopulmonary bypass. We performed CABG successfully without cardiopulmonary bypass in two patients with multivessel coronary disease who were failed to intervene with percutaneous transluminal coronary angioplasty. We herein report the two cases.

  • PDF

The Characteristics of a Bypass Air Conditioning System for Load Variation (부하변동에 대한 바이패스 공조시스템의 특성)

  • 김보철;신현준;김정엽
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation (고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구)

  • Ahn, Jae Hwan;Joo, Youngju;Yoon, Won Jae;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

ASSESSMENT of CORE BYPASS FLOW IN A PRISMATIC VERY HIGH TEMPERATURE REACTOR BY USING MULTI-BLOCK EXPERIMENT and CFD ANALYSIS (다중블록실험과 전산유체해석을 통한 블록형 초고온가스로의 노심우회유량 평가)

  • Yoon, S.J.;Lee, J.H.;Kim, M.H.;Park, G.C.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.95-103
    • /
    • 2011
  • In the block type VHTR core, there are inevitable gaps among core blocks for the installation and refueling of the fuel blocks. These gaps are called bypass gap and the bypass flow is defined as a coolant flows through the bypass gap. Distribution of core bypass flow varies according to the reactor operation since the graphite core blocks are deformed by the fast neutron irradiation and thermal expansion. Furthermore, the cross-flow through an interfacial gap between the stacked blocks causes flow mixing between the coolant holes and bypass gap, so that complicated flow distribution occurs in the core. Since the bypass flow affects core thermal margin and reactor efficiency, accurate prediction and evaluation of the core bypass flow are very important. In this regard, experimental and computational studies were carried out to evaluate the core bypass flow distribution. A multi-block experimental apparatus was constructed to measure flow and pressure distribution. Multi-block effect such as cross flow phenomenon was investigated in the experiment. The experimental data were used to validate a CFD model foranalysis of bypass flow characteristics in detail.

Sequential Bypass Effects in the Stenosed Coronary Artery (협착이 발생된 관상동맥내 시퀜셜 문합의 효과)

  • Roh, Hyung-Woon;Suh, Sang-Ho;Kwon, Hyuck-Moon;Lee, Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1919-1922
    • /
    • 2003
  • Bypass anastomosis are frequently adopted for surgical treatments. After the bypass grafting, the bypass artery is often occluded due to restenosis and/or anastomotic neointimal fibrous hyperplasia phenomena. Optimal coronary bypass anastomosis should be investigated to improve the patency for the arterial bypass techniques. The objective of this study is to investigate the influence of bypass with sequential bypass effects in the stenosed coronary artery. Numerical analyses are focused on the understanding of the flow patterns for different sequential anastomosis techniques. Blood flow field is treated as two-dimensional incompressible laminar flow. The finite volume method is adopted for discretization of the governing equations. The Carreau model is employed as the constitutive equation for blood. To find the optimal sequential bypass anastomotic configurations, the mass flow rates at the outlet of different models are compared quantitatively.

  • PDF

The Change of Derum and Urine Amylase Level Following Cardiopulmonary Bypass in the Patients with Congenital heart disease (선천성 심기형 환아에서 체외순환후 혈청 및 소변 Amylase치의 변화)

  • Baek, Hui-Jong;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.28 no.10
    • /
    • pp.892-899
    • /
    • 1995
  • Pancreatitis is a known complication of cardiac surgery with cardiopulmonary bypass. Although ischemia is believed to be a factor, the exact cause of pancreatitis after cardiopulmonary bypass remains unknown.We prospectively studied 67 consecutive patients undergoing cardiac surgery with cardiopulmonary bypass for evaluation of the pancreatic injury after cardiopulmonary bypas. Serial measurement of amylase level in serum and urine was done postoperatively. Hyperamylasemia was detected in 15 patients[22.4% , of whom no patient had pancreatitis. There was no significant difference between serum amylase level and parameters such as cardiopulmonay bypass time, aortic cross clamp time, mean blood pressure, rectal temperature, flow rate, and use of circulatory arrest during cardiopulmonary bypass. Hyperamylasuria was detected in 8 patients[11.9% , and urine amylase level was elevated significantly in the groups with prolonged cardiopulmonary bypass, mean blood pressure more than 40mmHg, and rectal temperature more than 20 $^{\circ}$C. We recommend that serum amylase level and/or amylase-creatinine clearance ratio is measured for ealy detection and management of pancreatitis after cardiopulmonary bypass.

  • PDF

A Study on the Decrease of Compressor Discharge Temperature Using Subcooling Bypass Technology (Subcooling Bypass Technology를 적용한 압축기 토출 냉매 온도 감소에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.326-332
    • /
    • 2009
  • The purpose of the study is to decrease the refrigerant temperature at the outlet of the compressor under high thermal load conditions for air cooled vapor compression refrigeration system. The subcooling bypass line called subcooling bypass technology(SBT) is installed to the window type A/C system to investigate the performance test. The standard air calorimeter test method is applied to measure the refrigerant temperature at the outlet of the compressor, cooling capacity, power consumption, and system EER. The refrigerant temperature at the outlet of the compressor decreases as the bypass rate increases. When the bypass rate is 8.2%, the refrigerant temperature at the outlet of the compressor decreases $2.8^{\circ}C$ while the cooling capacity and EER are the same as the conventional A/C unit.

Effects of the Geometric Dimensions on the Hemodynamics of Aorto-Coronary Bypass (Aorto-Coronary Bypass의 기하학적 형상이 관상동맥의 혈류특성에 미치는 영향)

  • Suh, S.H.;Roh, H.W.;Yoo, S.S.;Kwon, H.M.;Kim, D.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.254-257
    • /
    • 1996
  • An aorto-coronary bypass graft is frequently adopted for the interventional therapy of the diseased atherosclerotic coronary artery grafting. The bypass artery is often occluded due to restenosis and/or anastomotic neointimal fibrous hyperplasia after bypass graft. The optimal aorto-coronary bypass procedure must be studied in order to improve patency rate for the arterial bypass techniques. The objective of this study is to investigate the influences of geometric dimensions of bypass on the hemodynamics around the anastomosis in the stenosed coronary artery with aorto-coronary bypass.

  • PDF

A Clinical Analysis of Atherosclerosis Obliterance in the Lower Extremity (폐쇄성 하지 동맥 경화증의 임상적 고찰)

  • 김종만
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.333-341
    • /
    • 1990
  • aortoiliac pattern, Group II; femoropopliteal pattern and Group g; tibioperoneal pattern. A majority of patients belonged to group I [27 cases], 8 patients came under group II .and none in group g. Thirty patients underwent bypass operation with autogenous saphenous vein or synthetic graft with or without concomitant lumbar sympathectomy. Remaining 5 patients were operated on with sympathectomy only, Bypass procedures were anatomic bypass in 22 cases: aortoiliac artery bypass in 11 cases, femoropopliteal artery bypass in 10 cases, sequential femoropopliteal artery bypass in one case and extra-anatomic bypass in 8 cases, axillary-bifemoral artery bypass in one case and femorofemoral artery bypass in 7 cases. Postoperative complications which mainly composed of superficial wound infection[5 cases] which were treated without any significant sequel in all cases and thrombosis[2 cases]. Three patients died whose causes of death were acute renal failure in 2 cases and myocardial infarction in other, The overall patency, rate was 70Zo in 5 years. In conclusion, the clinical pattern and operative outcome were similar to he western pattern and all cases of death did not related to operative procedures and ischemic symptoms were relieved by bypass operations except several cases. I think and recommend that all patients suffering chronic arterial insufficiency by atherosclerosis obliterans ought to be managed with urgent and adequate operative procedure.

  • PDF