• Title/Summary/Keyword: bus split

Search Result 25, Processing Time 0.021 seconds

Power Distribution and Coordinated Control for a Power Split Hybrid Electric Bus

  • Wang, Feng;Zhong, Hu;Ma, Zi-Lin;Mao, Xiao-Jian;Zhuo, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.593-598
    • /
    • 2008
  • The power distribution is proposed to determine the target operating points of the system components as the basis for maximal the efficiency of the overall system for a power split dual electric machine hybrid electric bus. The coordinated control is constructed on the basis of the power distribution. The basic coordinated control is implemented to satisfy the driver's power demand, in which both the dynamic characteristics of the engine and the dual electric machine are explicitly taken into account. Moreover, the improved coordinated control is suggested to suppress engine dynamic operation and rich fuel injection.

Comparison of Fault Current Limiting Characteristics According to Facility in Power System (전력계통의 사고전류 저감 설비별 특성 비교)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Lim, Sung-Hun;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.127-129
    • /
    • 2005
  • We investigated the fault current limiting characteristics according to the various facilities in power system. Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such as short circuits are increasing higher, which causes the ratings of circuit breakers(CBs) to increase. Upgrading or replacement of CBs is not difficult from the technical and economical point of view. Bus split is being adopted into a part of 154 kV power systems, but it has adverse effects such as overload to neighboring power systems, increased voltage fluctuation, and decreased power system stability. For 345 kV power systems, the bus split measure is not feasible and dc reactors are being suggested. The superconducting fault current limiter is a protection gear of new concept that limits fault current automatically in a few milliseconds. It can also provide the effect of CB capacity increase, relaxation of power machine criteria, enhancement in power system reliability, and flexible power system operation.

  • PDF

Modal Split Forecasting of Tour-Bus Based on Changing Demand Between Tour-Bus and Cars (관광객의 수요변화에 따른 관광버스 분담율 추정에 관한 연구)

  • 장명순;강창욱
    • Journal of Korean Society of Transportation
    • /
    • v.11 no.3
    • /
    • pp.21-30
    • /
    • 1993
  • When the cars were not popular, the majority of travellers used the tour-bus. As the total number of cars increases every year, the pattern of travelling means is changing. This paper develops statistical models to predict the number of cars, to estimate the macket share of road transportation between tour-bus and cars.

  • PDF

A Study on the Classification of Transportation Connections in Seoul Subway Adjacent Area Using Portfolio Analysis (Portfolio분석을 이용한 서울시 역세권 지하철 연계수단간 유형분류 연구 - 서울시 25개 행정구역을 중심으로 -)

  • Kim, Tae-Ho;Park, Jun-Tae;Son, Sang-Ho;Park, Je-Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.1329-1338
    • /
    • 2015
  • This article aims to develop model for the right policy Tools available from the cause analysis regarding the regional differences of subway modal split in Seoul metropolitan area. This allows two major factors of the most influential subway modal split to be proved and Portfolio Analysis is conducted. The results are as follows. Firstly, the two primary factors affecting subway modal split were shown as subway adjacent area and local line bus. It signifies that expansion of subway adjacent area, establishing the number of the subway stations and increase of local line bus are required in order to improve a diminishing subway modal split. Following that, pattern of the improvement to strengthen better subway connections are classified according to the two areas which are Concentration Area of Improvement in Subway Station Area (CAISSA) and Concentration Area of Improvement in Local Bus (CAILB). Our study revealed that Ganbukgu, Seodaemungu, Geumcheongu, and Gwanakgu were selected as the area of CAILB and Songpagu, and Junggu were selected as the area of CAISSA. As all things are considered, transportation policy makers should be taken into account in the two main factors driven by our study according to types in order to enhance the future subway share proportion.

Study on Optimization of Generation System in Series HEV Bus (직렬형 하이브리드 전기버스에서의 발전 시스템 최적화에 관한 연구)

  • Jung, Dae-Bong;Min, Kyoung-Doug;Jo, Yong-Rae;Lim, Yong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.773-779
    • /
    • 2011
  • In order to improve fuel economy and emissions, many studies of HEV have been conducted. However, most of these studies concentrate on parallel or power-split HEVs. Series-type HEVs have some advantages over parallel and power-split HEVs. One is that the engine is operated at high efficiency since the engine and the driveshaft are decoupled. Nevertheless, the optimization of the powertrain system of series HEV has not been specifically addressed. We conduct an optimization of the generation system of a series HEV based on the series HEV bus. The main objectives are to simulate the system and to compare the fuel economies of conventional and optimized generation systems.

Decision Making on Bus Splitting Locations Using a Modified Fault Current Constrained Optimal Power Flow (FCC-OPF)

  • Song, Hwachang;Vovos, Panagis N.;Cho, Kang-Wook;Kim, Tae-Sun
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.76-85
    • /
    • 2016
  • This paper presents a method of decision on where bus splitting is needed to reduce fault current level of power systems and to satisfy the fault current constraints. The method employs a modified fault current constrained optimal power flow (FCC-OPF) with X variables for the candidate locations of splitting and for decision making on whether to split or not, it adopts soft-discretization by augmenting inversed U-shaped penalty terms. Also, this paper discusses the procedure on the adequate selection of bus splitting locations based on the results of the modified FCC-OPF, to reduce the total number of the actions taken.

A Study on the Bus-Tie Application of 154kV HTS-FCL in Korean Power System (실계통에서의 154kV HTS-FCL Bus-Tie 최적 적용방안에 관한 연구)

  • Kim Jong-Yul;Yoon Jae Young;Lee Seung Rvul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.226-233
    • /
    • 2005
  • As the power demand has been increasing, a fault current problem is becoming more serious in real power system. Various ways like bus-split operation, transmission line open operation, are used in Korean power system for solving the problem. In this time, superconducting FCL(Fault Current Limiter) has been developed as a vary attractive alternative since HTS(High Temperature Superconductivity) was discovered. Korea, a project developing superconducting FCL to apply to 154kV transmission system is proceeding. Therefore, a power system analysis for SFCL application to power system is necessary, This paper presents the determination of quenching resistance and the selection of optimal cites when 154kV HTS-FCL is applied to Korean power system.

A Development of Parallel Type Hybrid Drivetrain System for Transit Bus Part 3 : Optimal Driving Control Algorithm (버스용 병렬형 하이브리드 동력전달계의 개발(III) 제 3 편;최적 주행 제어 알고리즘)

  • 조한상;이장무;박영일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.182-197
    • /
    • 1999
  • Described in this paper is an optimal driving control algorithm which focused on the improvement of fuel economy and the minimization of pollutant emissions in the parallel type hybrid drivertrain system for transit bus. For the energy balance among components such as engine, induction machine and buttery, the algorithm for power split ration determine is proposed. When it is implemented in the hybrid electric control unit(HECU) , using the sub-optimal method and the approximate technique , it is possible to save the memory , to shorten the calculation time, and to achieve the efficient driving actually. A Shift strategy for automated manual transmission is the other side of the driving control algorithm. It enables to select the optimal gear by using several shift maps which were predefined from the proposed method in this paper, As a results of driving simulation, it is proved that these algorithms make the hybrid drivetrain system to reduce fuel consumption and emissions considerably and to have the ability to the efficient use of battery.

  • PDF

A Study on the Transmission Overload Relief by Fast Switching (고속 스위칭에 의한 송전선로 과부하 해소 연구)

  • Cho, Yoon-Sung;Lee, Han-Sang;Jang, Gilsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1053-1058
    • /
    • 2013
  • Because of computational burden and complex topology of substation, a transmission overload relief using circuit-breaker switching was very complex and difficult. However, a on-line algorithm for reducing the overloads in transmission lines has made progress due to the advance of IT technology. This paper describes the methodology for alleviating the overloads in transmission lines by circuit-breaker switching. First, the severe contingency lists and substations were selected from the results of contingency analysis. Then the switch combinations are determined using circuit-breakers of the selected substation. The topology changes are limited to equipment outage, bus split, island split, bus merge and island merge. Finally, the fast screening and full analysis methods are used to analyze the overload in transmission lines. To verify the performance of the proposed methodology, we performed a comprehensive test for both test system and large-scale power systems. The results of these tests showed that the proposed methodology can accurately alleviate the overloads in transmission lines from online data and can be applied to on-line applications.

Size Reduction and Performance Analysis of the Bit-map Table Used in the Bus-based Shared Memory System (버스기반의 공유메모리 시스템에서 사용된 비트맵 테이블의 크기 축소와 성능 분석)

  • Woo, Jong-Jung;Lee, Ka-Young
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.1
    • /
    • pp.24-32
    • /
    • 1998
  • The bus contention among bus-based shared-memory multiprocessors limits their performance. In addition, under split bus transaction environment, multiprocessors may make some memory requests unnecessary stand by in the memory access buffer, which makes system performance worse. This unnecessary stand-by can be eliminated by maintaining the bitmap table which contains the status bit for each memory block. However, this mechanism requires a great size of SRAM for the status information, which is fully mapped from the whole memory blocks. To solve this problem, we propose a bitmap cache which exploits partial mapping and locality of references. The simulation results show that the proposed system can greatly reduce the capacity of SRAM for the status information with little deteriorating its performance.

  • PDF