• Title/Summary/Keyword: burst size

Search Result 155, Processing Time 0.025 seconds

Propulsion Installation Design on Wing-Mounted-Nacelle Type (주익장착방식의 추진기관 장착설계)

  • 진광석;최광윤;공창덕
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.1
    • /
    • pp.88-94
    • /
    • 1998
  • Installation design methods and results of an aircraft engine on the wing-mounted-nacelle type aircraft has been presented in this paper. The design process starts from design requirements and constraints and covers some major aspects of the engine installation design such as wing-nacelle interference drag, roll clearance, ground clearance, nose gear collapse margin, rotor burst and fuel tank capacity. The method was applied to 100-seat class airplane(K100). Results of the design suggest optimum nacelle location and nacelle installation angle(toe-in, incidence, droop angle) which satisfies in stalled engine performance and size/location of wing dry day.

  • PDF

Characterization of the bacteriophage P4 sid+ derivative overcoming P2sir-associated helper inefficiency through DNA conformational adaptation (DNA 형태 적응을 거쳐 P2sir-관련 도움파지 비효율성을 극복하는 박테리오파지 P4 sid+ 유도체 정성 연구)

  • Kim, Kyoung-Jin
    • Korean Journal of Microbiology
    • /
    • v.52 no.1
    • /
    • pp.120-124
    • /
    • 2016
  • A certain size of DNA (28-29 kb long) to be packaged into P2-size head and the mutation in sid gene of bacteriophage P4 are the major factors to overcome "P2 sir-associated helper inefficiency". To clarify whether the presence of sid mutation is essential to overcome "P2 sir-associated helper inefficiency" or not, we tested the P4 derivative, P4 delRI::kmr, which is $sid^+$ and whose genome size supposed to be 28.5 kb long in the case of being packaged into $P2_{sir3}$-sized large head. As P4 delRI::kmr showed the low EOP with P2 sir3 lysogen, P4 delRI::kmr phage stock was prepared in P2 sir3 lysogen host to increase the EOP with P2 sir3 lysogen. Through this process, P4 delRI::kmr had been adapted for P2 sir3 lysogen. With a CsCl buoyant equilibrium density gradient experiment and gel electrophoresis of the isolated DNA, it was evident that the adaptation of P4 delRI::kmr for P2 sir3 lysogen was caused by the conformational change of DNA to be packaged into large head. The burst size determination experiments with P4 delRI::kmr phage stock adapted for P2 sir3 lysogen and normal P4 delRI::kmr phage stock showed that not the sid mutation but the size of DNA to be packaged (28-29 kb long) was essential to overcome "P2 sir-associated helper inefficiency".

An Admission Control for End-to-end Performance Guarantee in Next Generation Networks (Next Generation Networks에서의 단대단 성능 보장형 인입제어)

  • Joung, Jin-Oo;Choi, Jeong-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8B
    • /
    • pp.1141-1149
    • /
    • 2010
  • Next Generation Networks (NGN) is defined as IP-based networks with multi-services and with multi-access networks. A variety of services and access technologies are co-existed within NGN. Therefore there are numerous transport technologies such as Differentiated Services (DiffServ), Multi-protocol Label Switching (MPLS), and the combined transport technologies. In such an environment, flows are aggregated and de-aggregated multiple times in their end-to-end paths. In this research, a method for calculating end-to-end delay bound for such a flow, provided that the information exchanged among networks regarding flow aggregates, especially the maximum burst size of a flow aggregate entering a network. We suggest an admission control mechanism that can decide whether the requested performance for a flow can be met. We further verify the suggested calculation and admission algorithm with a few realistic scenarios.

Adaptive Burst Size-based Loss Differentiation for Transmitting Massive Medical Data in Optical Internet (광 인터넷에서 대용량 의학 데이터 전송을 위한 적응형 버스트 길이 기반 손실 차등화 기법)

  • Lee, Yonggyu
    • Journal of Digital Convergence
    • /
    • v.20 no.3
    • /
    • pp.389-397
    • /
    • 2022
  • As increasing the growth of the Internet in medical area, a new technology to transmit effectively massive medical data is required. In optical internet, all OBS nodes have fiber delay lines, hardware components. These components are calculated under some optimal traffic conditions, and this means that if the conditions change, then the components should be altered. Therefore, in this article a new service differentiation algorithm using the previously installed components is proposed, which is used although the conditions vary. When traffic conditions change, the algorithm dynamically recalculates the threshold value used to decide the length of data bursts. By doing so, irrelevant to changes, the algorithm can maintain the service differentiation between classes without replacing any fiber delay lines. With the algorithm, loss sensitive medical data can be transferred well.

Effect of Particle Shape and Size of Calcium Carbonate on Physical Properties of Paper (탄성칼슘에 성상이 종이물성에 미치는 영향)

  • 한영림;서영범
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.29 no.1
    • /
    • pp.7-12
    • /
    • 1997
  • This study was intended to investigate the proper shape and size of calcium carbonate for the improvement of paper properties and its end use performance. We loaded calcium carbonate of various shapes and size in the handsheet and measured their physical and optical properties. Results obtained from the study are summarized as follows : 1. Due to different particle shapes and sizes, precipitated calcium carbonate (PCC) contributed greater to bulk improvement than ground calcium carbonate (GCC). Scalenohedral form of PCC produced the bulkiest sheet, GCC made the sheet bulkier as average particle size increases. 2. Tensile strength increased as average particle size was increasing. GCC kept tensile strength more effectively than PCC. The effect of particle size on tensile strength was much more pronounced as filler addition level was increasing. 3. Over the average particle size of 6.99$\mu$m, GCC gave much higher burst strength and internal bond than PCC did. In the filler levels of 20% and 30%, GCC by using bigger size fillers showed 50~100% improvement in some cases than PCC at the same filler content. 4. Tear strength increased as average particle size was increasing. At the filler level of 30%, PCC decreased tear greatly. 5. Over the average particle size of 13.56$\mu$m, GCC kept bending stiffness greater than PCC. Due to its shape, Scalenohedral form of PCC showed higher stiffness than others at the same particle size. 6. Cubic and acicular form of PCC improved light scattering coefficient very effectively. Light scattering coefficient of GCC decreased as average particle size increased. 7. Both of particle shape and size of filler were important factor in developing optical properties and bending stiffness. Particle size was the only important factor in developing other strength properties

  • PDF

Construction and characterization of the bacteriophage P4 derivatives whose genome size suitable for packaging into a P2sir3-sized head (P2 sir3-sized head에 packaging 되기 용이한 크기의 박테리오파지 P4 유도체 조성과 정성 연구)

  • Kim, Kyoung-Jin
    • Korean Journal of Microbiology
    • /
    • v.51 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • The term "P2 sir-associated helper inefficiency" has been used to define the inefficient helper capability of P2 sir mutants for their satellite bacteriophage P4. The aim of this study was to investigate the factors overcoming P2 sir-associated helper inefficiency. At first, we verified whether the P2 cos region containing P4 sid71 cosP2 could overcome P2 sir-associated helper inefficiency with P2 sir3. The result was that P4 sid71 cosP2 could not overcome P2 sir-associated helper inefficiency with P2 sir3. Instead of cos region of P2, the size of the DNA packaged into a $P2_{sir}$-sized head seems to be important for overcoming P2 sir-associated helper inefficiency. In the present work, three kinds of P4 derivatives with packaged DNA sizes between those of P4 ost1 and P4 ost2, were constructed through DNA manipulation. In one P4 derivative, P4 sid71 delRI::apr, the size of the packaged DNA was identified with a CsCl buoyant equilibrium density gradient experiment. According to the burst sizes of the P4 derivatives, they could overcome P2 sir3-associated helper inefficiency. The size of the P4 derivative DNA suitable for packaging into a $P2_{sir3}$-sized head was 28-29 kb.

Preparation and Evaluation of Bupivacaine Microspheres by a Solvent Evaporation Method (II) (용매증발법에 의한 부피바카인 마이크로스피어의 제조 및 평가 (II))

  • 곽손혁;이시범;이종수;이병철;황성주
    • YAKHAK HOEJI
    • /
    • v.45 no.6
    • /
    • pp.623-633
    • /
    • 2001
  • Various bupivacaine-loaded microspheres were prepared using poly(d,1-lactide) (PLA) and poly(d,1-lactic-co-glycolide) (PLGA) by a solvent evaporation method for the sustained release of drug. The effects of process conditions such as drug loading, polymer type and solvent type on the characteristics of microspheres were investigated. The prepared microspheres were characterized for their drug loading, size distribution, surface morphology and release kinetics. Drug loading efficiency and yield of PLGA micro- spheres were higher than those of PLA microspheres. The prepared microspheres had an average particle size below 5${\mu}{\textrm}{m}$. The particle size range of microspheres was 1.65~2.24${\mu}{\textrm}{m}$. As a result of SEM, the particle size of PLA microspheres was smaller than that of PLGA microspheres. In morphology studies, microspheres showed a spherical shape and smooth surface in all process conditions. In thermal analysis, bupivacaine-loaded microspheres showed no peaks originating from bupivacaine. This suggested that bupivacaine base was molecular-dispersed in the polymer matrix of microspheres. The release pattern of the drug from microspheres was evaluated for 96 hours. The initial burst release of bupivacaine base decreased with increasing the molecular weight of PLGA, and the drug from microspheres released slowly. In conclusion, bupivacaine-loaded microspheres were successfully prepared from poly(d,1-lactide) and poly (d,1- lactic-co-glycolide) polymers with different molecular weights allowing control of the release rate.

  • PDF

Preparation and Reconstitution of Core-shell Type Nanoparticles of Poly(ε -caprolactone)/Poly(ethyleneglycol)/Poly(ε -caprolactone) Triblock Copolymers

  • Jeong, Young-Il;Ryu, Jae-Gon;Kim, Young-Hoon;Kim, Sung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.6
    • /
    • pp.872-879
    • /
    • 2002
  • One of the improtant characteristics of core-shell type nanoparticles is the long-term storage and reuse as an aqueous injection solution when required. For this reason, reconstruction of lyophilized core-shell type nanoparticles is considered to be essential . BAB type triblock copolymers differ from AB type diblock copolymers, which contain the A block as a hydrophilic part and the B block as a hydrophobic part. by not being easily redistributed into phosphate-buffered saline (PBS, pH 7.4, 0.1 M). Therefore, lyophilized core-shell type nanoparticles of CEC triblock copolymer were reconstituted using a somication process with a bar-type sonicator in combination with a freezing-thawing process. Soncation for 30s only resuspended CEC nanoparticles in PBS; their particle size distribution showed a monomodal pattern with narrow size distribution. The bimodal size distribution pattern and the aggregates were reduced by further sonication for 120 s but these nanoparticles showed a wide size distribution. The initial burst of drug release was increased by reconstitution process. The reconstitution of CEC core-shell type nanoparticles by freezing-thawing resulted in trimodal distribution pattern and formed aggregates, although freezing-thawing process was easier than sonication . Drug release form CEC nanoparticles prepared by freezing-thawing was slower than from the original dialysis solution. Although core-shell typenanoparticles of CEC triblock copolymers were not easily performed. Cytotoxicity testing of core-shell type nanoparticles of CEC-2 triblock copolymers containing clonazepam (CNZ) was performed using L929 cells. Cytotoxicity of CNZ was decreased by incorporation into nanoparticles.

Miniaturized Ground-Detection Sensor using a Geomagnetic Sensor for an Air-burst Munition Fuze (공중폭발탄용 신관에 적용 가능한 초소형 지자기 지면감지 센서)

  • LEE, HanJin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.97-105
    • /
    • 2017
  • An air-burst munition is limited in space, so there is a limit on the size of the fuze and the amount of ammunition. In order to increase a firepower to a target with limited ammunition, it is necessary to concentrate the firepower on the ground instead of the omnidirectional explosion after flying to the target. This paper explores the design and verification of a ground-detection sensor that detects the direction of the ground and determines the flight-distance of an air-burst munition using a single axis geomagnetic sensor. Prior to the design of the ground detection sensor, a geomagnetic sensor model mounted on the spinning air-burst munition is analyzed and a ground-detection algorithm by simplifying this model is designed. A high speed rotating device to simulate a rotation environment is designed and a geomagnetic sensor and a remote-recording system are fabricated to obtain geomagnetic data. The ground detection algorithm is verified by post-processing the acquired geomagnetic data. Taking miniaturization and low-power into consideration, the ground detection sensor is implemented with analog devices and the processor. The output signal of the ground detection sensor rotating at an arbitrary rotation speed of 200 Hz is connected to the LED (Light Emitting Diode) in the high speed rotating device and the ground detection sensor is verified using a high-speed camera.

Effect of Acoustic Emission During a Fatigue Test with Defect for Type II Gas Cylinder (피로시험시 발생하는 음향방출신호를 이용한 Type II Gas Cylinder의 손상평가)

  • Jee, Hyun-Sup;Lee, Jong-O;Ju, No-Hoe;So, Cheal-Ho;Lee, Jong-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • This research seeks to evaluate damage on type II gas cylinder by an acoustic emission test when executing 20000 cycles fatigue test and thereafter burst test. Used gas cylinders in the experimental are three types as follows; one is sound cylinder, others are cylinders which contain longitudinal and transverse artificial defect. The size of artificial defect is a depth of 3 mm, width of 3 mm and length of 50 mm. In the case of the cylinder which artificial defect, unlike the expectation that it will burst in low pressure, the burst pressure of the cylinder did not differ much according to whether or not there were defects. However, when there was longitudinal defect, the location of burst was near the location of defect. This leads to the effect in which the thickness of the composite material becomes thinner according to the length of the longitudinal defect and this is judged to have an effect on the location of initiation and growth of crack in the liner. Also, for the acoustic emission signal, when there is longitudinal defect, the ratio of an event occurring at defect position among overall hits is more than 50 %, and the source location also accords very precisely with defect position.