• 제목/요약/키워드: buildup region

검색결과 31건 처리시간 0.023초

두경부암 치료를 위한 6MV X-선 산란판의 제작과 산란분포 측정 (Skin Dose Distributions with Spoiler of 6MV x-ray for Head and Neck Tumor)

  • 이호수;이종걸;이병준
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.176-184
    • /
    • 1995
  • It is very useful benefits to use the megavoltage photon beams in deep site tumor radiotherapy for skin sparing effects. But, In some cases of head and mock tumors, it is often necessary to use spoiler for rapid buildup on skin region. A spoiler with tissue equivalent material to be moved between the patients and the collimator can increase or control the skin dose and buildup region due to position and thickness of the spoiler was measured. Then, the effect of spoiler on skin dose and build up region in protruded tumor of head and neck was evaluated quantitatively. The measurements were abtained with PTW 2334 chamber (Markus type) on a polystylene phantom for 6MV x-ray from an accelerator.

  • PDF

Evaluation of photon radiation attenuation and buildup factors for energy absorption and exposure in some soils using EPICS2017 library

  • Hila, F.C.;Javier-Hila, A.M.V.;Sayyed, M.I.;Asuncion-Astronomo, A.;Dicen, G.P.;Jecong, J.F.M.;Guillermo, N.R.D.;Amorsolo, A.V. Jr.
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3808-3815
    • /
    • 2021
  • In this paper, the EPICS2017 photoatomic database was used to evaluate the photon mass attenuation coefficients and buildup factors of soils collected at different depths in the Philippine islands. The extraction and interpolation of the library was accomplished at the recommended linear-linear scales to obtain the incoherent and total cross section and mass attenuation coefficient. The buildup factors were evaluated using the G-P fitting method in ANSI/ANS-6.4.3. An agreement was achieved between XCOM, MCNP5, and EPICS2017 for the calculated mass attenuation coefficient values. The buildup factors were reported at several penetration depths within the standard energy grid. The highest values of both buildup factor classifications were found in the energy range between 100 and 400 keV where incoherent scattering interaction probabilities are predominant, and least at the region of predominant photoionization events. The buildup factors were examined as a function of different soil silica contents. The soil samples with larger silica concentrations were found to have higher buildup factor values and hence lower shielding characteristics, while conversely, those with the least silica contents have increased shielding characteristics brought by the increased proportions of the abundant heavier oxides.

Quality Degradation of Semiconductor Transistors by 1MeV Electron Beam Exposure

  • Lee, Tae-Hoon;Gyuseong Cho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(2)
    • /
    • pp.401-406
    • /
    • 1997
  • This paper presents preliminary results on the degradation of BJTs(Bipolar Junction Transistors) and MOSFETs(Metal Oxide Semiconductor Field Effect Transistors) by 1MeV electron beam. Exposure experimental results show that the change of minority-carrier life time in base region dominates the behavior of BJTs and that the buildup of charges in oxide region can affect the value of threshold voltage for MOSFETs. It was possible to correlate the decrease of the minority-carrier life time of BJTs with irradiation dose, while the shift of MOSFETs' threshold voltage was not only a function of charge buildup in oxide region.

  • PDF

표피로 부터 buildup 영역까지 흡수되는 암치료용 방사선의 선량분석 (Analysis of dose from surface to near the buildup region in the therapeutic X-ray beam)

  • Vahc, Young-Woo
    • 한국의학물리학회지:의학물리
    • /
    • 제6권2호
    • /
    • pp.41-50
    • /
    • 1995
  • 암치료용 방사선 (15 MV의 에너지를 갖는 광자선) 속에 있는 흡수선량과 불순전자 또는 산란 광자에 관한 분포를 광자선 면적 크기에 따른 변화와 광자선 면적을 반만 차폐시킨 선속에 대하여 연구 조사하였다. 광자선의 에너지를 15MV로 주어질때 광자선 최대 흡수깊이 $d^{max}$ 값은 광자선의 면적을 증가시키면 시킬수록(5$\times$5 에서 30$\times$30$\textrm{cm}^2$)d$_{max}$ 값은 감소된다. 이는 광자선 즉 방사선을 발생시키는 가속기 기계 속에 있는 여러 부품 (flattening filter, collimator jaws, tray holder,……)과 상호작용하여 형성된 불순전자로 인하여 d$_{max}$ 값이 표피쪽으로 이동되어 buildup 영역에 높은 선량흡수를 갖게 된다. 최대 흡수깊이 값을 계산할 때 이러한 현상을 고려하지 않으면 그릇된 data 값을 갖는다. 대부분의 불순 전자는 광자선 중심에 주로 분포하며 그 진행거리는 30.0mm 이하의 짧은 거리를 갖는다. 이 불순전자가 30.0mm이내(즉 buidup 영역)에 전부 흡수되므로 buidup 영역은 높은 선량흡수를 갖게되어 해를 주게된다. 그러므로 이러한 불순전자를 제거시키므로서 buidup 영역에 낮은 선량 흡수를 갖을 뿐 아니라 d$_{max}$ 값도 역시 깊은 곳까지 이동시켜 치료에 효과적인 방법 이 창출된다.

  • PDF

Monte Carlo Based Planning System for a Beam Spoiler

  • 강세권;조병철;박희철;배훈식
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.56-56
    • /
    • 2003
  • For the treatment of superficial tumors like squamous cell carcinoma of the head and neck, 6 MV photon beam is not appropriate and a spoiler is widely used to increase dose in the buildup region, while preserving the skin sparing effect. However, commercially available treatment planning systems assume a normal unspoiled beam, thereby cannot predict the buildup dose with spoiler accurately. We aimed to implement a Monte Carlo (MC) based planning system to apply it to the radiation treatment of head and neck. Lucite with thickness of 10-mm was used for the beam spoiler with Siemens Primus 6 MV photon beam. BEAM/DOSXYZ MC system was employed to model the linac and the spoiler. To verify the calculation accuracy of MC simulations, the percent depth doses (PDDs) and profiles with and without spoiler were measured using a parallel-plate chamber. For the MC based planning, we adopted a hybrid interface system between Pinnacle (Philips, USA) and BEAM/DOSXYZ to support treatment parameters of Siemens linac and the spoiler. The measurements of PDDs and profiles agreed with the corresponding MC simulations within 2% (lSD), which demonstrate the reliability of our MC simulations. The spoiler generated electrons make a contribution to the absorbed dose up to depth of 2cm, which shows that the dominant source of increased dose from spoiler system is the contaminating electrons created by the spoiler. The whole procedures necessary for MC based treatment planning were performed seamlessly between Pinnacle and BEAM/DOSXYZ system. This ability helps to increase the clinical efficiency of the spoiler technique. In conclusion, we implemented a MC based treatment planning system for a 6 MV photon beam with a spoiler. We demonstrate sophisticated MC technique makes it possible to predict dose distributions around buildup region accurately.

  • PDF

원자력발전소 증기발생기 전열관의 결함발생 예방을 위한 전자기 비파괴 검사방법 개발 (Development of an Electromagnetic Nondestructive Testing Method for the Prevention of Defects in Steam Generator Tubes at Nuclear Power Plant)

  • 신영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.83-85
    • /
    • 1996
  • Major cause of defects in steam generator tubes at nuclear power plant is the accumulation of magnetite and other byproducts of corrosion in the crevice gap between support plates and tubes. Since damaged tubes result in contamination of the secondary coolant by the radioactive primary coolant, they represent a safety hazard. Early detection of magnetite buildup is, therefore, imperative in order to take remedial measures such as chemical flushing. Although the eddy current testing is being used for the inspection of steam generator tubes, the interpretation of resulting signals is generally a difficult task. This paper uses the phase of sensor coil emf as the test signal to find a way of easier signal interpretation. Numerical study using FEM shows that the shape of resulting signal is good for identifying the relative position of the probe to the support plate, and for discreminating the different shapes and degrees of magnetite buildup in the crevice gap region.

  • PDF

EVALUATION OF THE UNCERTAINTIES IN THE MODELING AND SOURCE DISTRIBUTION FOR PRESSURE VESSEL NEUTRON FLUENCE CALCULATIONS

  • Kim, Yong-Il;Hwang, Hae-Ryong
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.237-241
    • /
    • 2001
  • The uncertainties associated with fluence calculation at the pressure vessel have been evaluated for the Korean Next Generation Reactor, APR1400. To obtain uncertainties, sensitivity analyses were performed for each of the parameters important to calculated fast neutron fluence. Among the important parameters to the overall uncertainties, reactor modeling and core neutron source were examined. Mechanical tolerances, composition and density variations in the reactor materials as well as application of $r-{\theta}$ geometry in rectilinear region contribute to uncertainty in the reactor modeling. Depletion and buildup of fissile nuclides, instrument error related to core power level, uncertainty of fuel pin burnup, and variation of long-term axial peaking factors are main contributors to the core neutron source uncertainty. The sensitivity analyses have shown that the uncertainty in the fluence calculation at the reactor pressure vessel is +12%.

  • PDF

Experimental Study of Spatial and Temporal Dynamics in Double Phase Conjugation

  • Kwak, Keum-Cheol;Yu, Yong-Hun;Lim, Tong-Kun;Lee, Dae-Eun;Son, Jung-Young
    • Journal of the Optical Society of Korea
    • /
    • 제3권2호
    • /
    • pp.41-46
    • /
    • 1999
  • Spatial and temporal dynamics arising in a photorefractive crystal(BaTiO3) during the process of double phase conjugation was studied experimentally. We studied the dynamical effects caused by the buildup of the diffraction grating and turn on of phase conjugated beams, as well as the spatial effects caused by the finite transverse coupling of beams and the propagation direction of beams. We observed conical emission in DPCM. We believe that various temporal and spatial instabilities are due to movement of the nonlinear grating. For a real beam coupling and constructive interaction of interference fringes in the crystal, we observed steady, periodic, irregular temporal behavior. And, by the calculation of the correlation index, we found that the spatial correlation decreased as the transverse interaction region was increased.

Analytical Consideration of Surface Dose and Kerma for Megavoltage Photon Beams in Clinical Radiation Therapy

  • Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Razmjoo, Sasan;Zabihzadeh, Mansour;Fatahiasl, Jafar;Maskni, Reza;Abdalvand, Neda;Asgarian, Zeynab;Shamsi, Azin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.153-157
    • /
    • 2016
  • Background: In radiation therapy, estimation of surface doses is clinically important. This study aimed to obtain an analytical relationship to determine the skin surface dose, kerma and the depth of maximum dose, with energies of 6 and 18 megavoltage (MV). Materials and Methods: To obtain the dose on the surface of skin, using the relationship between dose and kerma and solving differential equations governing the two quantities, a general relationship of dose changes relative to the depth was obtained. By dosimetry all the standard square fields of $5cm{\times}5cm$ to $40cm{\times}40cm$, an equation similar to response to differential equations of the dose and kerma were fitted on the measurements for any field size and energy. Applying two conditions: a) equality of the area under dose distribution and kerma changes in versus depth in 6 and 18 MV, b) equality of the kerma and dose at $x=d_{max}$ and using these results, coefficients of the obtained analytical relationship were determined. By putting the depth of zero in the relation, amount of PDD and kerma on the surface of the skin, could be obtained. Results: Using the MATLAB software, an exponential binomial function with R-Square >0.9953 was determined for any field size and depth in two energy modes 6 and 18MV, the surface PDD and kerma was obtained and both of them increase due to the increase of the field, but they reduce due to increased energy and from the obtained relation, depth of maximum dose can be determined. Conclusions: Using this analytical formula, one can find the skin surface dose, kerma and thickness of the buildup region.