• Title/Summary/Keyword: building rooftop

Search Result 128, Processing Time 0.02 seconds

Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building (초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가)

  • Ryu, Taek-Hyoung;Um, Jung-Sup
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

Comparative Evaluation of Surface Temperature among Rooftop Colors of Flat Roof Building Models : Towards Performance Evaluation of Cool Roof (평지붕 건물 축소모형의 지붕색에 대한 표면 온도의 비교평가: 쿨루프 성능평가 차원에서)

  • Ryu, Taek Hyoung;Um, Jung-Sup
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.83-91
    • /
    • 2013
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. It is specifically proposed that the changing trends of rooftop surface temperature in the flat roof building model could be used effectively as an indicator to reduced cooling load reduced by cool roof since it can present stable temperature record, that is not influenced according to the nearby physical as well as human variables. The temperature of cool roof in summer was lower around $20^{\circ}C$, compared to the general roofs. Such a seasonal or daily comparative study for rooftop temperature in the building model will highlight that the cool roof efficiency could be calculated in much area-wide context according to rooftop color distribution in urban residential area. It is anticipated that this research output could be used as a valuable reference in identifying energy saving by cool roof since an objective monitoring has been proposed based on the rooftop temperature in the building model, fully quantitative performance of thermal infrared image.

A CFD Study of Near-field Odor Dispersion around a Cubic Building from Rooftop Emissions

  • Jeong, Sang Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.153-164
    • /
    • 2017
  • Odor dispersion around a cubic building from rooftop odor emissions was investigated using computational fluid dynamics (CFD). The Shear Stress Transport (here after SST) $k-{\omega}$ model in FLUENT CFD code was used to simulate the flow and odor dispersion around a cubic building. The CFD simulations were performed for three different configurations of cubic buildings comprised of one building, two buildings or three buildings. Five test emission rates were assumed as 1000 OU/s, 2000 OU/s, 3000 OU/s, 4000 OU/s and 5000 OU/s, respectively. Experimental data from wind tunnels obtained by previous studies are used to validate the numerical result of an isolated cubic building. The simulated flow and concentration results of neutral stability condition were compared with the wind tunnel experiments. The profile of streamline velocity and concentration simulation results show a reasonable level of agreement with wind tunnel data. In case of a two-building configuration, the result of emission rate 1000 OU/s illustrates the same plume behavior as a one-building configuration. However, the plume tends to the cover rooftop surface and windward facet of a downstream building as the emission rate increases. In case of a three-building configuration, low emission rates (<4000 OU/s) form a similar plume zone to that of a two-building configuration. However, the addition of a third building, with an emission rate of 5000 OU/s, creates a much greater odorous plume zone on the surface of second building in comparison with a two-building configuration.

Generation of 3D Building Model by Grouping of 3D Line Segments (3차원 선소의 Grouping에 의한 3차원 건물 모델 발생)

  • Kang, Yon-Uk;Woo, Dong-Min
    • Journal of IKEEE
    • /
    • v.10 no.1 s.18
    • /
    • pp.40-48
    • /
    • 2006
  • This paper presents a new rooftop surface estimation method from 3D line segments. 3D rooftop surface estimation is based on the hierarchical grouping and initiated by 3D line merging for the disconnected 3D line segments. Merged 3D lines are applied to the detection of rooftop by surface estimating technique. To estimate surfaces we detect L-corner and T-corner points, and find fixed reliable junction points. The hypothesis of the possible rooftop surfaces are estimated as polygonal surfaces by these fixed junction points and building's rooftop models are generated by testing the possible surfaces in terms of assumptions of building surface properties. We carried out experiments by synthetic images on Avenches data set and the experimental results showed that we could reliably build 3D model with 3D surfaces, errors of which came up with 0.4 - 1.3 meter, 2.5 times more accurate than the elevation date from the conventional area-based stereo.

  • PDF

A Study on a Rooftop Biotope Creation Technique Reflecting the UNESCO Biosphere Reserve Concept - Focusing on the UNESCO Building Rooftop - (유네스코 생물권보전지역 개념을 도입한 옥상 생물서식공간 조성 기법에 관한 연구 -유네스코회관 옥상을 사례로-)

  • Kim, Kwi-Gon;Cho, Dong-Gil
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.4
    • /
    • pp.32-43
    • /
    • 2004
  • Targeting a rooftop biotope created in urban area, this study aims at verifying a creation technique reflecting an urban biosphere reserve concept as well as its function as the habitats of various wild animals. To this end, a set of processes of a biosphere reserve-based basic conception and master plan, sectoral plans, construction and monitoring were applied to the rooftop of 12-story UNESCO Building in Seoul. In particular, the rooftop habitats were divided into core area, buffer zone and transition area, and habitats and facilities suitable to the characteristics of each space were planned. By aligning a plantation planning map with environmental conditions such as topography and water, creation of diverse habitats was enabled. As a result, a set of various habitats including wetlands, wild grassland, shrubs, forest trees and vegetable fields was created at the site. Species living in these habitats included 148 plant species, 62 insect species, 2 amphibian species, 3 fishery species and 3 bird species. The rooftop eco-park of UNESCO Building, which was created one year ago, is assessed as an important space for conservation of biodiversity as well as a place where a biosphere reserve concept was well applied. Meanwhile, for this rooftop biotope to be a pioneer of urban biosphere reserve-based types, a number of principles & methodologies suggested in this study need to be applied, In a perspective of landscape ecology, maintenance efforts should be linked with green areas in neighboring areas, which are the sources of species, In addition, considering that the rooftop biotope is a restored ecosystem, theories and approaches from restoration ecology should be applied. On-going monitoring on environmental changes is also required as the site is located in the urban center, Ultimately, rooftop biotopes including the case study area should contribute in promoting the socio-economic, cultural, and spiritual sustainability as well as environmental sustainability of a city.

Relationship between the Cultural History of Modern Japan and Rooftop Gardens

  • Yamada, Hiroyuki;Yabu, Shinobu
    • Proceedings of the Korean Institute of Landscape Architecture Conference
    • /
    • 2007.10b
    • /
    • pp.157-161
    • /
    • 2007
  • Full-scale ferro-concrete building technology came was introduced in Japan in Meiji $35{\sim}40(1902{\sim}1907)$ and heralding the beginning of urban modernization. On the roofs of these new architectural constructions, full-scale rooftop gardens were also developed. We consider that gardens established on the roofs of hotel and department stores created a new, modernized garden culture, which greatly influenced the early modern urban culture of Japan, the drama of which it conceived based on the impression in a rooftop garden is made. In this paper, we discuss the influence of Meiji-Era cultural and technological advances on rooftop gardens constructed during the Taisho $Era(1912{\sim}1926)$, as represented by the gardens of Kobe's Oriental Hotel, Tokyo's Mitsukoshi Department Store and Shimonoseki City's Akita Company. Photographic and print sources are utilized to analyze the design features and temporal changes of these pioneering rooftop gardens, as well as their influence on urban culture.

  • PDF

An Approach to Improve the Rooftop Space of Commercial Facilities (상업시설의 루프탑 공간 개선방안 연구)

  • Kim, Hye-Ri;Kim, Young-Hwa;Lee, Sang-Hong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.6
    • /
    • pp.93-103
    • /
    • 2018
  • In the past, the rooftop was a place where a water tank was to be installed, and a space of secretion and concealment such as a warehouse exposed in the air. It was because it was judged to hinder the beauty of a city as a whole without having any functional value per se. However, the roof portion is increasingly being utilized for a space such as a cafe, a pub, and a lounge as the rooftop is highly recognized as a place for leisure activities other than an idle space in modern times. Nonetheless, there are no detailed ordinances and criteria corresponding to such circumstances. For example, in case of the rooftop space, the building code applied to the rooftop space is a legal system when the rooftop was an idle space in the past though people have now accessed more increasingly to the rooftop than in the past. This study investigated the definition on the rooftop space evolved in accordance with the change of the rooftop space and the related legal system in Korea, and conducted a survey for the purpose of performing the field investigation for the analysis of physical status in 117 spaces that form the rooftop space in the rooftop of small-scale commercial facilities with 2 stories through 4 stories in Korea and analyze the recognition of users and analyzing the recognition of users. We analyzed the problems in the rooftop space through analysis of derived data, and suggested improvement plans.

Generation of 3D Building Model Using Estimation of Rooftop Surface (Rooftop 평면 추정에 의한 3차원 건물 모델 발생)

  • Kang, Yon-Uk;Woo, Dong-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2921-2923
    • /
    • 2005
  • This paper presents to generate 3D building model using estimation of rooftop surface after 3D line segment extraction using hybrid stereo matching techniques in terms of the co-operation of area-based stereo and feature-based stereo. we first performed a junction extraction from 3D line segment data which was obtained by stereo images, and finally generated building's reliable rooftop surface model using LSE(Least Square Error) method after creating surfaces by grouped and fixed junction points. we generated synthetic images for experimentation by photo-realistic simulation on Avenches data set of Ascona aerial images.

  • PDF

CFD Study on the Influence of Atmospheric Stability on Near-field Pollutant Dispersion from Rooftop Emissions

  • Jeong, Sang Jin;Kim, A Ra
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.47-58
    • /
    • 2018
  • The aim of this work is to investigate the effect of atmospheric stability on near-field pollutant dispersion from rooftop emissions of a single cubic building using computational fluid dynamics (CFD). This paper used the shear stress transport (here after SST) k-${\omega}$ model for predicting the flow and pollutant dispersion around an isolated cubic building. CFD simulations were performed with two emission rates and six atmospheric stability conditions. The results of the simulations were compared with the data from wind tunnel experiments and the result of simulations obtained by previous studies in neutral atmospheric condition. The results indicate that the reattachment length on the roof ($X_R$) obtained by computations show good agreement with the experimental results. However, the reattachment length of the rooftop of the building ($X_F$) is greatly overestimated compared to the findings of wind tunnel test. The result also shows that the general distribution of dimensionless concentration given by SST k-${\omega}$ at the side and leeward wall surfaces is similar to that of the experiment. In unstable conditions, the length of the rooftop cavity was decreased. In stable conditions, the horizontal velocity in the lower part around the building was increased and the vertical velocity around the building was decreased. Stratification increased the horizontal cavity length and width near surface and unstable stratification decreased the horizontal cavity length and width near surface. Maintained stability increases the lateral spread of the plume on the leeward surface. The concentration levels close to the ground's surface under stable conditions were higher than under unstable and neutral conditions.

A look at rooftop waterproofing methods that combine a circular adhesive insulated composite duplex exposure repellent with a airvent (원형 접착 절연형의 복합 복층형 노출 방수제와 탈기관을 결합한 옥상 방수 공법에 관한 고찰)

  • KIM, Yeong-Seok;JEON, Sang-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.236-237
    • /
    • 2021
  • In the waterproofing of the rooftop of reinforced concrete buildings, it is difficult to solve perfectly according to the proficiency of waterproofing materials, methods, and mechanics. Therefore, this study applies a Tricot Fabric Mesh to the behavior of the bottom concrete. In addition, it responds to the behavior of the concrete cracking, and the waterproofing and protective layer has developed a method to provide convenience for rooftop floor use by adhesion between the base and the waterproof layer with the use of high viscosity urethane to effectively move the surface deformation and surface vapor and install a airvent device on the wall.

  • PDF