• 제목/요약/키워드: building frame structures

검색결과 449건 처리시간 0.027초

RC 라멘조에 SMART Frame 적용 시 효용성 분석 (Performance Analysis of SMART Frame Applied to RC Column-Beam Structures)

  • 조원현;임채연;장덕배;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.168-169
    • /
    • 2015
  • SMART Frame is a composite precast concrete structure system to deliver the advantages of both steel frame and reinforced concrete. Many studies have established to date that SMART Frame is more advantageous than conventional frame-type structure in terms of structural stability, constructability, economic viability as well as reduction of construction schedule. However, such studies have focused primarily on wall-type or flat slab-type apartment housing structures, failing to include Rahmen structures in their scope. Accordingly, this study aims to analyze the benefits of potential application of SMART Frame to RC Rahmen structures. As the structural stability and constructability of SMART Frame is already proven, this study reviews its benefits from the perspective of cost reduction. Conclusion of this study will be used subsequently in predicting the benefits of SMART Frame when it is adapted to RC Rahmen structures.

  • PDF

복합구조물의 하부층수 변화에 따른 비선형 동적응답특성 (Nonlinear Dynamic Response Characteristics with Variations in the Lower Stories of Mixed Building Structures)

  • 강병두;전대한;김재웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.443-450
    • /
    • 2001
  • The Mixed building structures can be divided into three partition, namely, upper wall, lower frame, and transfer system which link two partitions. The purpose of this study is to investigate the nonlinear response characteristics of structures, as the stories of lower frame of mixed building structures changes. The recorded earthquake ground motions of EI Centro 1940 NS is adopted, and the maximum ground accelerations are adjusted to 55ga1, 110ga1, 220ga1, 330ga1. The conclusions of this study are the following. 1) The responses of model that the story of lower frame is one were different from those of other models. 2) The process of ductility hinge occurrence of member was ends of coupling beam of upper wall and ends of beam of lower frame in 55ga1, bases of shear wall on pit floor in 110ga1, and bases of column of 1F in 220ga1.

  • PDF

Seismic fragility analysis of wood frame building in hilly region

  • Ghosh, Swarup;Chakraborty, Subrata
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.97-107
    • /
    • 2021
  • A comprehensive study on seismic performance of wood frame building in hilly regions is presented. Specifically, seismic fragility assessment of a typical wood frame building at various locations of the northeast region of India are demonstrated. A three-dimensional simplified model of the wood frame building is developed with due consideration to nonlinear behaviour of shear walls under lateral loads. In doing so, a trilinear model having improved capability to capture the force-deformation behaviour of shear walls including the strength degradation at higher deformations is proposed. The improved capability of the proposed model to capture the force-deformation behaviour of shear wall is validated by comparing with the existing experimental results. The structural demand values are obtained from nonlinear time history analysis (NLTHA) of the three-dimensional wood frame model considering the effect of uncertainty due to record to record variation of ground motions and structural parameters as well. The ground motion bins necessary for NLTHA are prepared based on the identified hazard level from probabilistic seismic hazard analysis of the considered locations. The maximum likelihood estimates of the lognormal fragility parameters are obtained from the observed failure cases and the seismic fragilities corresponding to different locations are estimated accordingly. The results of the numerical study show that the wood frame constructions commonly found in the region are likely to suffer minor cracking or damage in the shear walls under the earthquake occurrence corresponding to the estimated seismic hazard level; however, poses negligible risk against complete collapse of such structures.

Seismic Performance of High-rise Moment-resisting RC Frame Structures with Vertical Setback

  • Jiang, Huanjun;Huang, Youlu;Li, Wannian
    • 국제초고층학회논문집
    • /
    • 제9권4호
    • /
    • pp.307-314
    • /
    • 2020
  • High-rise buildings with vertical setback are widely used in practice. From the field investigation of the past earthquakes, it was found that such kind of vertically irregular high-rise building structures easily suffer severe damage during strong earthquakes. This paper presents an extensive study on the earthquake responses of moment-resisting frame structures (MFS) popularly applied in high-rise buildings with vertical setback. Four groups of MFS are designed, including three groups of structures with vertical setback and one group of structures with the lateral stiffness varying along the building height but without vertical setback. The numerical models of the structures are established, and the time history analysis of the structures under different levels of earthquakes is conducted. The earthquake responses of the structures are compared. The influence of the ratio between the horizontal setback dimension and the previous plan dimension, the eccentricity of setback, and the position where the setback occurs on the seismic performance of structures is studied. The rationality of the provisions for the structures with vertical setback specified in the current design codes is checked by the findings from this study.

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Kumar, Pardeep;Petwal, Sandeep
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.401-413
    • /
    • 2019
  • The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.

프레임구조물의 터널시공에 따른 거동분석 (Response Analysis of Frame Structures with the Consideration of Tunnel Construction)

  • 손무락;박재현
    • 대한토목학회논문집
    • /
    • 제32권3C호
    • /
    • pp.121-127
    • /
    • 2012
  • 본 논문은 터널건설로 인해 발생된 인접지반에서의 지반변위가 프레임구조물에 미치는 영향을 터널 시공조건(지반손실)을 달리하면서 조사한 것이다. 터널굴착에 의해 발생된 지반변위에 노출된 4층 오픈 프레임구조물과 블록으로 채워진 프레임구조물이 서로 다른 시공조건(지반손실)에 노출될 때 발생되는 구조물 거동을 수치해석을 통해 조사하였다. 오픈 프레임구조물은 탄성구조물로서 모델링 한 반면, 블록으로 채워진 프레임구조물은 소요전단 및 인장강도 이상의 응력이 발생할 때 구조물에 실제크랙이 발생할 수 있도록 모델링하였다. 터널굴착유발 지반변위에 노출된 두 서로 다른 프레임구조물의 거동 및 손상정도를 터널 시공조건에 따라 조사하였으며, 발생된 구조물의 거동 및 손상정도는 구조물에 발생한 변형, 크랙크기 및 분포를 고려하여 서로 비교하였다. 뿐만 아니라, 다양한 시공조건(지반손실)의 변화에 의해 구조물에 유발될 수 있는 손상정도의 크기를 손상도 예측기준(Son and Cording, 2005)을 사용하여 제시하였다. 이러한 결과들은 향후 터널굴착으로 인해 유발되는 인접 프레임구조물의 손상을 제어하고 최소화하는데 필요한 정보를 제공할 것이다.

Optimal placement and design of nonlinear dampers for building structures in the frequency domain

  • Fujita, Kohei;Kasagi, Masatoshi;Lang, Zi-Qiang;Penfei, Guo;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1025-1044
    • /
    • 2014
  • In this paper, a systematic technique is proposed for the optimal placement and design of nonlinear dampers for building structures. The concept of Output Frequency Response Function (OFRF) is applied to analytically represent the output frequency response of a building frame where nonlinear viscous dampers are fitted for suppression of vibration during earthquakes. An effective algorithm is derived using the analytical representation to optimally determine the locations and parameters of the nonlinear dampers. Various numerical examples are provided to verify the effectiveness of the optimal designs. A comparison of the vibration suppression performance with that of the frame structure under a random or uniform damping allocation is also made to demonstrate the advantages of the new designs over traditional solutions.

동적 특성을 고려한 상주 양진당의 구조 안전성 평가 (Structural Safety Evaluation of Yangjindang in Sang-ju Using Vibration Characteristics)

  • 이가윤;이성민;김시윤;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.37-44
    • /
    • 2019
  • Yangjindang house, which is located in Sang-ju province of South Korea, is one of the special Hanok structures dated back to Joseon dynasty. This study aims to examine structural safety of the Yangjindang wood frame building considering dynamic parameters such as the natural frequency and damping ratio. The numerical model of the wood frame building is implemented using Midas Gen, especially the wood joint where column and beam were connected. The behavior of the actual frame building was compared with the modeling results. In addition, structure responses such as shear force, axial force, flexural moment and deflections were calculated and compared with the allowable limits. Numerical results show that, generally, despite of some local members shear failure, Yangjindang's structural response does not exceed the limitation according to current standards.

Development of Seismic Retrofit Devices for Building Structures

  • Kim, Jinkoo
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.221-227
    • /
    • 2019
  • In this paper passive seismic retrofit devices for building structures developed by the author in recent years are introduced. The proposed damping devices were developed by slightly modifying the configuration of conventional devices and enhancing their effectiveness. First a seismic retrofit system consisting of a pin-jointed steel frame and rotational friction dampers installed at each corner of the steel frame was developed. Then two types of steel slit dampers were developed; box-type slit damper and multi-slit damper. In addition, hybrid dampers were developed by combining a slit damper and a friction damper connected in parallel. Finally a self-centering system was developed by using preloaded tendons and viscous dampers connected in series. For each retrofit system developed, an appropriate analytical model was developed, and the seismic performance was verified by loading test and earthquake analysis of case study structures. The experimental and analysis results show that the proposed systems can be used efficiently to enhance the seismic performance of building structures.

점탄성물질 난류댐퍼를 이용한 V형 철골 브레이스 골조의 진동응답해석 (A Vibration Response Analysis of Steel Building Frame with V Shape Brace Vibrationally Controlled by Turbulent Flow Dampers Sealed by Visco-Elastic Material)

  • 이호;이상엽
    • 한국공간구조학회논문집
    • /
    • 제2권3호
    • /
    • pp.103-113
    • /
    • 2002
  • This thesis investigates vibration response characteristics of building frames in which dampers are installed. The frames belong to passively vibration-controlled. Structures which utilizes energy dissipation of mechanical dampers provided in the structure. In this thesis, a turbulent flow damper sealed by visco-elastic material was dealt with as the device of passive vibration control. To investigate the resisting force characteristics of the damper, harmonic vibratration tests were carried out. Based on the test results, a theoretical model of the damper resistance was presented and a method of identifying the model parameters was proposed. Shaking table tests of the frame with and without the dampers were carried out and the effectiveness of the damper was examined. The response of the frame with the dampers was reduced to 1/2 or 1/3 of the cases without the damper.

  • PDF