• Title/Summary/Keyword: building frame structures

Search Result 449, Processing Time 0.025 seconds

Performance Analysis of SMART Frame Applied to RC Column-Beam Structures (RC 라멘조에 SMART Frame 적용 시 효용성 분석)

  • Cho, Wonhyun;Lim, Chaeyeon;Jang, Duk Bea;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.168-169
    • /
    • 2015
  • SMART Frame is a composite precast concrete structure system to deliver the advantages of both steel frame and reinforced concrete. Many studies have established to date that SMART Frame is more advantageous than conventional frame-type structure in terms of structural stability, constructability, economic viability as well as reduction of construction schedule. However, such studies have focused primarily on wall-type or flat slab-type apartment housing structures, failing to include Rahmen structures in their scope. Accordingly, this study aims to analyze the benefits of potential application of SMART Frame to RC Rahmen structures. As the structural stability and constructability of SMART Frame is already proven, this study reviews its benefits from the perspective of cost reduction. Conclusion of this study will be used subsequently in predicting the benefits of SMART Frame when it is adapted to RC Rahmen structures.

  • PDF

Nonlinear Dynamic Response Characteristics with Variations in the Lower Stories of Mixed Building Structures (복합구조물의 하부층수 변화에 따른 비선형 동적응답특성)

  • 강병두;전대한;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.443-450
    • /
    • 2001
  • The Mixed building structures can be divided into three partition, namely, upper wall, lower frame, and transfer system which link two partitions. The purpose of this study is to investigate the nonlinear response characteristics of structures, as the stories of lower frame of mixed building structures changes. The recorded earthquake ground motions of EI Centro 1940 NS is adopted, and the maximum ground accelerations are adjusted to 55ga1, 110ga1, 220ga1, 330ga1. The conclusions of this study are the following. 1) The responses of model that the story of lower frame is one were different from those of other models. 2) The process of ductility hinge occurrence of member was ends of coupling beam of upper wall and ends of beam of lower frame in 55ga1, bases of shear wall on pit floor in 110ga1, and bases of column of 1F in 220ga1.

  • PDF

Seismic fragility analysis of wood frame building in hilly region

  • Ghosh, Swarup;Chakraborty, Subrata
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.97-107
    • /
    • 2021
  • A comprehensive study on seismic performance of wood frame building in hilly regions is presented. Specifically, seismic fragility assessment of a typical wood frame building at various locations of the northeast region of India are demonstrated. A three-dimensional simplified model of the wood frame building is developed with due consideration to nonlinear behaviour of shear walls under lateral loads. In doing so, a trilinear model having improved capability to capture the force-deformation behaviour of shear walls including the strength degradation at higher deformations is proposed. The improved capability of the proposed model to capture the force-deformation behaviour of shear wall is validated by comparing with the existing experimental results. The structural demand values are obtained from nonlinear time history analysis (NLTHA) of the three-dimensional wood frame model considering the effect of uncertainty due to record to record variation of ground motions and structural parameters as well. The ground motion bins necessary for NLTHA are prepared based on the identified hazard level from probabilistic seismic hazard analysis of the considered locations. The maximum likelihood estimates of the lognormal fragility parameters are obtained from the observed failure cases and the seismic fragilities corresponding to different locations are estimated accordingly. The results of the numerical study show that the wood frame constructions commonly found in the region are likely to suffer minor cracking or damage in the shear walls under the earthquake occurrence corresponding to the estimated seismic hazard level; however, poses negligible risk against complete collapse of such structures.

Seismic Performance of High-rise Moment-resisting RC Frame Structures with Vertical Setback

  • Jiang, Huanjun;Huang, Youlu;Li, Wannian
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.307-314
    • /
    • 2020
  • High-rise buildings with vertical setback are widely used in practice. From the field investigation of the past earthquakes, it was found that such kind of vertically irregular high-rise building structures easily suffer severe damage during strong earthquakes. This paper presents an extensive study on the earthquake responses of moment-resisting frame structures (MFS) popularly applied in high-rise buildings with vertical setback. Four groups of MFS are designed, including three groups of structures with vertical setback and one group of structures with the lateral stiffness varying along the building height but without vertical setback. The numerical models of the structures are established, and the time history analysis of the structures under different levels of earthquakes is conducted. The earthquake responses of the structures are compared. The influence of the ratio between the horizontal setback dimension and the previous plan dimension, the eccentricity of setback, and the position where the setback occurs on the seismic performance of structures is studied. The rationality of the provisions for the structures with vertical setback specified in the current design codes is checked by the findings from this study.

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Kumar, Pardeep;Petwal, Sandeep
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.401-413
    • /
    • 2019
  • The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.

Response Analysis of Frame Structures with the Consideration of Tunnel Construction (프레임구조물의 터널시공에 따른 거동분석)

  • Son, Moorak;Park, Jaehyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3C
    • /
    • pp.121-127
    • /
    • 2012
  • This paper investigates the response of frame structures with the consideration of tunnel construction (ground loss) conditions. The response of four-story open frame structure and block-infilled frame structures, which are subjected to tunnelling-induced ground movements, has been investigated in different construction (ground loss) conditions using numerical analysis. The open frame structure has been modelled as an elastic structure, while the block-infilled frame structure has been modelled to have real cracks when the shear and tensile stress exceed the maximum shear and tensile strength. The response of the two different frame structures has been investigated in terms of construction (ground loss) conditions considering the magnitude of deformations and cracks in structures. In addition, the damage levels, which are possibly induced in the structures, has been provided in terms of construction (ground loss) conditions using the state of strain damage estimation criterion (Son and Cording, 2005). The results of this study will provide a background for better understandings for controlling and minimizing building damage on nearby frame structures due to tunnelling-induced ground movements.

Optimal placement and design of nonlinear dampers for building structures in the frequency domain

  • Fujita, Kohei;Kasagi, Masatoshi;Lang, Zi-Qiang;Penfei, Guo;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • v.7 no.6
    • /
    • pp.1025-1044
    • /
    • 2014
  • In this paper, a systematic technique is proposed for the optimal placement and design of nonlinear dampers for building structures. The concept of Output Frequency Response Function (OFRF) is applied to analytically represent the output frequency response of a building frame where nonlinear viscous dampers are fitted for suppression of vibration during earthquakes. An effective algorithm is derived using the analytical representation to optimally determine the locations and parameters of the nonlinear dampers. Various numerical examples are provided to verify the effectiveness of the optimal designs. A comparison of the vibration suppression performance with that of the frame structure under a random or uniform damping allocation is also made to demonstrate the advantages of the new designs over traditional solutions.

Structural Safety Evaluation of Yangjindang in Sang-ju Using Vibration Characteristics (동적 특성을 고려한 상주 양진당의 구조 안전성 평가)

  • Lee, Ga-Yoon;Lee, Sung-Min;Kim, Si-Yun;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Yangjindang house, which is located in Sang-ju province of South Korea, is one of the special Hanok structures dated back to Joseon dynasty. This study aims to examine structural safety of the Yangjindang wood frame building considering dynamic parameters such as the natural frequency and damping ratio. The numerical model of the wood frame building is implemented using Midas Gen, especially the wood joint where column and beam were connected. The behavior of the actual frame building was compared with the modeling results. In addition, structure responses such as shear force, axial force, flexural moment and deflections were calculated and compared with the allowable limits. Numerical results show that, generally, despite of some local members shear failure, Yangjindang's structural response does not exceed the limitation according to current standards.

Development of Seismic Retrofit Devices for Building Structures

  • Kim, Jinkoo
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.221-227
    • /
    • 2019
  • In this paper passive seismic retrofit devices for building structures developed by the author in recent years are introduced. The proposed damping devices were developed by slightly modifying the configuration of conventional devices and enhancing their effectiveness. First a seismic retrofit system consisting of a pin-jointed steel frame and rotational friction dampers installed at each corner of the steel frame was developed. Then two types of steel slit dampers were developed; box-type slit damper and multi-slit damper. In addition, hybrid dampers were developed by combining a slit damper and a friction damper connected in parallel. Finally a self-centering system was developed by using preloaded tendons and viscous dampers connected in series. For each retrofit system developed, an appropriate analytical model was developed, and the seismic performance was verified by loading test and earthquake analysis of case study structures. The experimental and analysis results show that the proposed systems can be used efficiently to enhance the seismic performance of building structures.

A Vibration Response Analysis of Steel Building Frame with V Shape Brace Vibrationally Controlled by Turbulent Flow Dampers Sealed by Visco-Elastic Material (점탄성물질 난류댐퍼를 이용한 V형 철골 브레이스 골조의 진동응답해석)

  • Lee, Ho;Lee, Sang-Yeob
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.3 s.5
    • /
    • pp.103-113
    • /
    • 2002
  • This thesis investigates vibration response characteristics of building frames in which dampers are installed. The frames belong to passively vibration-controlled. Structures which utilizes energy dissipation of mechanical dampers provided in the structure. In this thesis, a turbulent flow damper sealed by visco-elastic material was dealt with as the device of passive vibration control. To investigate the resisting force characteristics of the damper, harmonic vibratration tests were carried out. Based on the test results, a theoretical model of the damper resistance was presented and a method of identifying the model parameters was proposed. Shaking table tests of the frame with and without the dampers were carried out and the effectiveness of the damper was examined. The response of the frame with the dampers was reduced to 1/2 or 1/3 of the cases without the damper.

  • PDF