• 제목/요약/키워드: building dynamic characteristics

검색결과 372건 처리시간 0.025초

Acceleration amplification characteristics of embankment reinforced with rubble mound

  • Jung-Won Yun;Jin-Tae Han;Jae-Kwang Ahn
    • Geomechanics and Engineering
    • /
    • 제36권2호
    • /
    • pp.157-166
    • /
    • 2024
  • Generally, the rubble mound installed on the slope embankment of the open-type wharf is designed based on the impact of wave force, with no consideration for the impact of seismic force. Therefore, in this study, dynamic centrifuge model test results were analyzed to examine the acceleration amplification of embankment reinforced with rubble mound under seismic conditions. The experimental results show that when rubble mounds were installed on the ground surface of the embankment, acceleration response of embankment decreased by approximately 22%, and imbalance in ground settlement decreased significantly from eight to two times. Furthermore, based on the experimental results, one-dimensional site response (1DSR) analyses were conducted. The analysis results indicated that reinforcing the embankment with rubble mound can decrease the peak ground acceleration (PGA) and short period response (below 0.6 seconds) of the ground surface by approximately 28%. However, no significant impact on the long period response (above 0.6 seconds) was observed. Additionally, in ground with lower relative density, a significant decrease in response and wide range of reduced periods were observed. Considering that the reduced short period range corresponds to the critical periods in the design response spectrum, reinforcing the loose ground with rubble mound can effectively decrease the acceleration response of the ground surface.

TMD 적용에 따른 Twisted 비정형 건축물의 변위 응답 분석 (Displacement Response Analysis of Twisted Irregular Buildings According to TMD)

  • 유상호;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제24권1호
    • /
    • pp.89-98
    • /
    • 2024
  • In this study, we investigated the dynamic characteristics of three irregular building models to analyze the effectiveness of displacement response control with Tuned Mass Damper (TMD) installation in twisted irregular buildings. The three irregular models were developed with a fixed angle of twist per story at one degree, subjected to three historical seismic loads and resonant harmonic loads. By designing TMDs with linear and dashpot attributes, we varied the total mass ratio of the installed TMDs from 0.00625% to 1.0%, encompassing a total of 10 values. Two TMDs were installed at the center of the top story of the analysis model in both X and Y directions to evaluate displacement response control performance based on TMD installation. Our findings suggest that the top displacement response control performance was most effective when a 1.0% TMD was installed at the top layer of the analysis model.

초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상 (Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.19-33
    • /
    • 2008
  • 구조물에 고유한 진동수,모드형태 및 감쇠비 등과 같은 동적성능치를 추출하기 위하여 25층 및 42층 건물에 대하여 자연진동에 의한 동적계측실험을 수행하였다. 고려된 건물은 주요 횡하중 지지기구로서 코아벽체 혹은 전단벽체가 추가된 철근콘크리트건물이며, 입면 혹은 평면상으로 골조가 혼합된 구조형식을 나타낸다. 특히, 25층 건물은 측면에 위치한 코아벽체 이외에 상부로부터 내려오는 전단벽 구조가 4층 바닥이하에서 골조형식으로 전환되는 복잡한 구조이다. 이와 같은 이유 및 건물 주방향의 유사한 강성배치로 매우 근접하고 혼합된 모드형태가 예상되어 시스템판별 시 어려움이 예상된다. 현재까지 개발된 다양한 시스템판별법을 대상건물의 자연진동 실측기록에 적용하여 모달계수를 유도하였으며, 그 결과를 비교 분석하였다. 3개의 주파수영역 및 4개의 시간영역에 근거한 응답의존 시스템판별법이 고려되었다. 서로 다른 시스템판별법에 의하여 추출된 고유진동수 및 감쇠비는 대체로 상당한 일치를 보였으나, 모드형태는 사용된 방법에 따라 정도가 다르게 불일치를 나타냈다. 실험으로부터 추출한 성능치와 초기 유한요소해석 값을 비교해 본 결과 대상건물 모두 적어도 저차 3개의 고유진동수에서 2배 정도의 차이를 나타냈다. 실험과 해석결과의 일치를 위하여 몇몇 수동모델향상이 시도되었으며, 허용할 만한 결과를 획득하였다. 사용된 시스템판별법에 대하여 각자의 장, 단점에 대하여 기술하였으며, 본 연구와 같은 실제 대형구조물에 대하여 자동모델향상기법을 적용할 시 예상되는 문제점에 대하여 토의하였다.

영상처리기법을 이용한 다중 변위응답 측정 알고리즘의 검증 (Verification of Multi-point Displacement Response Measurement Algorithm Using Image Processing Technique)

  • 김성완;김남식
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.297-307
    • /
    • 2010
  • 최근 토목, 건축 구조물의 유지관리 기술에 대한 관심이 커지고 있으며 구조물의 성능저하 및 노후화 등으로 구조적 안전성의 검토가 요구되는 구조물의 수가 급증하고 있는 실정이다. 그리고 구조물의 노후화 및 부재의 균열 등으로 인하여 강성이 저하되면 구조물의 동특성에 변화가 나타나게 되며 구조물의 실제 거동상태에서 동특성을 분석하여 손상부위와 손상정도를 정확히 판단하는 것은 중요한 문제이다. 구조물 모니터링에 사용되는 대표적 계측장비가 동적계측기이다. 기존의 동적계측기는 측정 센서와 장비를 연결하는 케이블 길이가 길어질 경우 신뢰할 수 있는 데이터를 얻기 힘들고 각 센서와 계측기를 1:1로 연결하는 방식을 취하고 있어 비경제적이다. 따라서 센서를 부착하지 않고 원거리에서 진동을 측정하는 방법이 필요하다. 구조물의 진동을 계측하기 위하여 적용 가능한 비접촉식 방법으로는 레이저의 도플러효과, GPS를 이용하는 방법 및 영상처리기법 등이 대표적이다. 레이저의 도플러효과를 이용하는 방법은 정확도가 상대적으로 높지만 비경제적이며, GPS를 이용하는 방법은 장비가 고가이고 신호 자체의 오차와 데이터 취득속도의 제약이 있는 단점이 있다. 그러나 영상신호를 이용하는 방법은 간편하고 경제적이며 접근이 어려운 구조물의 진동 및 동특성 추출에 적합하다. 기존에도 센서를 대신하여 카메라의 영상신호를 이용하는 연구가 수행되기도 하였으나, 기존의 방법은 구조물에 부착된 표적의 한 지점을 기록한 후 영상처리기법을 이용하여 진동을 측정하는 방법으로서 측정 대상이 비교적 국한적일 수 있다. 그러므로 본 연구에서는 영상처리기법을 이용하여 구조물의 다중 변위응답을 측정할 수 있는 방법의 타당성을 검증하기 위하여 진동대 실험 및 현장재하실험을 수행하였다.

마이크로 가스터빈 시험 장치 개발 (Development of Test Facility for Micro Gas Turbine)

  • 임형수;최범석;박무룡;황순찬;박준영;서정민;방제성;임영철;오인균;김병옥;조주형
    • 한국유체기계학회 논문집
    • /
    • 제18권5호
    • /
    • pp.42-48
    • /
    • 2015
  • To improve the core technology of the micro gas turbine, the performance test facility was developed. This paper is focusing on the explanation of the characteristics of micro gas turbine and its assist devices. Major part of micro gas turbine were radial type of compressor, annular type of combustor, radial type of turbine, thrust foil bearing, radial foil bearing and generator. The assist devices were consist of exhaust duct, inverter, data acquisition system, load bank and test cell. Before building up the test facility, the component test was previously conducted to confirm the component performance. After the test facility was prepared, the motoring test was conducted to investigate the rotor dynamic characteristics of the micro gas turbine. Also, the part load performance test was performed. With a developed micro gas turbine test facility, the improved core technology about the micro gas turbine can be suggested to the related industries.

Seismic loss-of-support conditions of frictional beam-to-column connections

  • Demartino, Cristoforo;Monti, Giorgio;Vanzi, Ivo
    • Structural Engineering and Mechanics
    • /
    • 제61권4호
    • /
    • pp.527-538
    • /
    • 2017
  • The evaluation of the loss-of-support conditions of frictional beam-to-column connections using simplified numerical models describing the transverse response of a portal-like structure is presented in this paper considering the effects of the seismic-hazard disaggregation. Real earthquake time histories selected from European Strong-motion Database (ESD) are used to show the effects of the seismic-hazard disaggregation on the beam loss-of-support conditions. Seismic events are classified according to different values of magnitudes, epicentral distances and soil conditions (stiff or soft soil) highlighting the importance of considering the characteristics of the seismic input in the assessment of the loss-of-support conditions of frictional beam-to-column connections. A rigid and an elastic model of a frame of a precast industrial building (2-DoF portal-like model) are presented and adopted to find the minimum required friction coefficient to avoid sliding. Then, the mean value of the minimum required friction coefficient with an epicentral distance bin of 10 km is calculated and fitted with a linear function depending on the logarithm of the epicentral distance. A complete parametric analysis varying the horizontal and vertical period of vibration of the structure is performed. Results show that the loss-of-support condition is strongly influenced by magnitude, epicentral distance and soil conditions determining the frequency content of the earthquake time histories and the correlation between the maxima of the horizontal and vertical components. Moreover, as expected, dynamic characteristics of the structure have also a strong influence. Finally, the effect of the column nonlinear behavior (i.e. formation of plastic hinges at the base) is analyzed showing that the connection and the column are a series system where the maximum force is limited by the element having the minimum strength. Two different longitudinal reinforcement ratios are analyzed demonstrating that the column strength variation changes the system response.

Wind-induced responses and dynamic characteristics of a super-tall building under a typhoon event

  • Hua, X.G.;Xu, K.;Wang, Y.W.;Wen, Q.;Chen, Z.Q.
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.81-96
    • /
    • 2020
  • Wind measurements were made on the Canton Tower at a height of 461 m above ground during the Typhoon Vincente, the wind-induced accelerations and displacements of the tower were recorded as well. Comparisons of measured wind parameters at upper level of atmospheric boundary layer with those adopted in wind tunnel testing were presented. The measured turbulence intensity can be smaller than the design value, indicating that the wind tunnel testing may underestimate the crosswind structural responses for certain lock-in velocity range of vortex shedding. Analyses of peak factors and power spectral density for acceleration response shows that the crosswind responses are a combination of gust-induced buffeting and vortex-induced vibrations in the certain range of wind directions. The identified modal frequencies and mode shapes from acceleration data are found to be in good agreement with existing experimental results and the prediction from the finite element model. The damping ratios increase with amplitude of vibration or equivalently wind velocity which may be attributed to aerodynamic damping. In addition, the natural frequencies determined from the measured displacement are very close to those determined from the acceleration data for the first two modes. Finally, the relation between displacement responses and wind speed/direction was investigated.

무선 메쉬 네트워크에서 유전 알고리즘을 이용한 라우팅 메트릭 기법 (Using Genetic Algorithms for Routing Metric in Wireless Mesh Network)

  • 윤창표;신효영;유황빈
    • 융합보안논문지
    • /
    • 제11권1호
    • /
    • pp.11-18
    • /
    • 2011
  • 무선 메쉬 네트워크 기술은 유선과 유사한 전송속도를 갖는 무선망을 구축하는 기술을 의미하며, 유선 네트워크와 비교하여 보다 효율적인 망 구축의 편의성 및 유연성을 제공한다. 이러한 무선 메쉬 네트워크는 라우터 노드의 이동성이 적고 에너지 영향에도 제약이 적게 따른다는 특징을 갖고 있다. 그러나 다양한 종류의 네트워크로 구성되는 특징으로 인해서 다중 경로의 설정 및 선택 시에 발생할 수 있는 시스템 오버헤드 등 고려되어야 하는 사항들이 많다. 그러므로 이러한 네트워크 특성에 맞는 경로 설정 기술이 반영되는 네트워크의 설계 및 최적화에 주목할 필요가 있다. 본 논문에서는 다중 경로 설정 시 발생 할 수 있는 문제에 효과적으로 대응하기 위해 라우터 노드의 트래픽 상황에 따른 데이터 손실률과 대역폭 및 링크의 흡수를 평가 요소로 활용하여 유전 알고리즘을 통한 동적 경로 설정에 대한 해결방법으로 무선 메쉬 네트워크의 라우팅 메트릭 기법을 제안한다.

이민자 공동체의 공간적 경관 (Spatial Landscape of Immigrant Communities in Seoul)

  • 이자원
    • 문화기술의 융합
    • /
    • 제7권3호
    • /
    • pp.383-395
    • /
    • 2021
  • 도시 경관의 다양성은 건축물과 가로패턴, 그리고 사람들의 인문적 특성 이른바 언어와 색과 움직임 등의 동태적 특성에 의해 정립된다. 한국의 해외이주민의 증가와 함께 지역사회의 행정과 국토정책상 새로운 지침이 필요하다. 2000년대 이후 꾸준히 증가하는 외국인 이주민에 대해 행정, 사회학적, 그리고 지리적 연구가 이루어지고 있지만, 각 국가별 민족별 상이한 문화와 생활양식이 기존 주류사회와 어떠한 통합 과정을 거치고 안전하고 건강한 공간성을 구축할 수 있는지에 대한 정밀한 실험은 미흡한 상황이다. 통계적 데이터의 결핍된 부분과 소수 비율의 외국인 거주자에 대한 대표성을 파악하기에 한계가 있다. 지역사회의 통합적 전략에 대한 핵심요소를 지표화하기 위해서 외국인 이주자들의 거주지 행태와 공간적 특성이 우선 파악되어야 한다. 통계적으로 계량화하기 어려운 소수의 공동체에 관한 공간적 요소를 분석을 위해 경관적 접근을 실험해보고자 한다.

비선형 규칙파 조건에서 기존 케이슨 방파제에 신규 케이슨 추가설치에 따른 케이슨들 간의 상호작용 영향 평가 (Interaction Effect between Caissons by Installation of New Caisson on Existing Caisson Breakwater in Second Order Stokes Wave Condition)

  • 박민수
    • 한국해안·해양공학회논문집
    • /
    • 제33권6호
    • /
    • pp.345-356
    • /
    • 2021
  • 기존 케이슨 방파제의 구조적 안정성을 높이기 위해 신규 케이슨을 기존 케이슨 전면 또는 후면에 추가로 설치하여 보강하는 설계 및 시공사례가 발생되고 있다. 본 연구에서는 신규 케이슨이 추가로 설치되는 경우 입사하는 파랑과 구조물 간의 상호작용 영향에 따른 개별 케이슨에 작용하는 파력 특성을 분석하기 위해 상용프로그램인 ANSYS AQWA를 이용하여 수치해석을 수행하였다. 우선 주파수 영역에서 구조물에 작용하는 파력을 계산하여 개별 케이슨에 작용하는 파력 특성을 주기(주파수)별로 분석하였다. 그리고 특이한 파력분포 특성이 발생되는 주파수에 대해서는 시간영역 수치해석을 통해 개별 케이슨에 작용하는 동적파력 특성은 케이슨 간의 거리변화에 큰 영향을 받는 것을 확인하였다.