• Title/Summary/Keyword: building area

Search Result 3,899, Processing Time 0.034 seconds

A Neural Network Model for Building Construction Projects Cost Estimating

  • El-Sawalhi, Nabil Ibrahim;Shehatto, Omar
    • Journal of Construction Engineering and Project Management
    • /
    • v.4 no.4
    • /
    • pp.9-16
    • /
    • 2014
  • The purpose of this paper is to develop a model for forecasting early design construction cost of building projects using Artificial Neural Network (ANN). Eighty questionnaires distributed among construction organizations were utilized to identify significant parameters for the building project costs. 169 case studies of building projects were collected from the construction industry in Gaza Strip. The case studies were used to develop ANN model. Eleven significant parameters were considered as independent input variables affected on "project cost". The neural network model reasonably succeeded in estimating building projects cost without the need for more detailed drawings. The average percentage error of tested dataset for the adapted model was largely acceptable (less than 6%). Sensitivity analysis showed that the area of typical floor and number of floors are the most influential parameters in building cost.

A Basic Study on Analysis of the Impact of Building Shape on Safety Accidents (건물의 형상이 안전사고에 미치는 영향분석에 관한 기초연구)

  • Son, Seunghyun;Kim, Ji-Myung;Ahn, Sungjin;Han, Bumjin;Na, Youngju;Kim, Taehui
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.27-28
    • /
    • 2022
  • There is a limit to preventing various types of safety accidents in advance at construction sites. Even for buildings of the same total floor area, it is expected that the more complex the building shape or the higher the number of floors, the higher the probability of a safety accident. Therefore, it is necessary to analyze the effect of the shape of a building on safety accidents using safety accident data generated during actual construction. The purpose of this study is to analyze the impact of building shape on safety accidents. As a result, the R2 value of shape factor and safety accident was 0.901, and the R2 value of construction difficulty and safety accident was 0.944. In the future, the results of this study will be used as basic data for improving safety management related systems.

  • PDF

Optimizing the Life Cycle Cost of a Solar Water Heating System in an Office Building Through Simulation (사무소건물 태양열급탕시스템의 LCC 최적화 시뮬레이션)

  • Ko, Myeong-Jin;Choi, Doo-Sung;Chang, Jae-D.;Kim, Yong-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.859-866
    • /
    • 2010
  • This study examined the economics of a solar water heating system for an office building using life cycle cost (LCC) optimization simulations. The numerical simulations were conducted with TRNSYS and GenOpt employing the Hooke-Jeeves algorithm. The solar collector area, slope, mass flow rate per collector area and storage tank volume were selected as the main design parameters of the solar water heating system. The LCC optimization simulations of the system were carried out for cases where water temperature was $60^{\circ}C$ and $50^{\circ}C$. The results showed that for water temperature at $60^{\circ}C$ and $50^{\circ}C$ the collector area could be decreased by 17% and 28%, storage tank volume could be decreased by 49% and 54%, and mass flow rate per collector area increased by 5% and 9% respectively compared to a non-optimized system. The LCC of the system was reduced by 4% for $60^{\circ}C$ and 7% for $50^{\circ}C$. The initial installation cost of the system was reduced by 24% for $60^{\circ}C$ and 34% for $50^{\circ}C$. However, the operating cost of the system increased by 16% for $60^{\circ}C$ and 36% for $50^{\circ}C$ compared to a traditional solar water heating system.

A Study on the Remodeling Strategy for the Equipment Intensive Areas of General Hospitals - Focused on the Diagnosis/Treatment Areas, the Supply Areas - (종합병원 설비집약적인 부문의 리모델링 방안에 관한 연구 - 중앙진료부와 공급부를 중심으로 -)

  • Kim Ha-Jin
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.1
    • /
    • pp.100-108
    • /
    • 2005
  • If remodeling is defined as activities that restore the overall function of a building up to the standards currently demanded rather than as a simple replacement or repair of old facilities and equipment, the main task of remodeling should be the reduction in differences between areas, establishment of a functional linkage between departments and setup of a smooth circulation system. Therefore, this study is an analysis of remodeling strategies and construction processes to resolve major tasks of remodeling. Through this research we acquire concluding remarks. 1) The remodeling strategies of equipment-intensive areas can be divided into two measures: utilizing the existing buildings (the main buildings) the most, and of concentrated relocation in the new buildings. The former method is advantageous in that the main building serves as a center in hospital layouts because concentrated placement of the diagnosis/ treatment area and the supply area benefit the overall operation in terms of functions. However, the measure has limits in that it is difficult to install the facilities and equipment of the new demands due to the low ceilings, which serve as a potential challenge in future growth and changes. 2) The latter measure is the one in which equipment-intensive areas and the areas that are absolutely short of space are first placed in the new buildings while other areas (the outpatient area, the administration area and the miscellaneous areas) are in the existing building (main building). Given the possibility of development In the future, concentrated placement in the new buildings can be said to be more effective order to actively address future growth and changes.

Estimation of Potential Population by IED(Improvised Explosive Device) in Intensive Apartment Area (아파트 밀집지역 급조폭발물 테러 발생 시 잠재피해인구 추정)

  • Lee, Kangsan;Choi, Jinmu
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.76-86
    • /
    • 2015
  • In this study, we presented a method for estimating the potential population damage of the Seoul Nowon-gu area in the event of a terrorist using a vehicle improvised explosive devices (IED). Using the object-based building extraction method with orthophoto image, the area of the apartment has been determined, and the apartment's height and level were estimated based on the elevation data. Using the population estimation method based on total floor area of building, each apartment resident population was estimated, and then potential population damage at the time of terrorist attacks was estimated around the subway station through a scenario analysis. Terrorism damage using IED depends on the type of vehicle greatly because of the amount loadable explosives. Therefore, potential population damage was calculated based on the type of vehicle. In the results, the maximum potential damage population during terrorist attacks has been estimated to occur around Madeul station, Nowon-gu. The method used in this study can be used various population estimation research and disaster damage estimation.

  • PDF

On the Pressurization for Smoke Control in Building Fires (건물화재에서의 가압방연 설계에 관한 연구)

  • Kim, Myeong-Bae
    • 연구논문집
    • /
    • s.29
    • /
    • pp.39-48
    • /
    • 1999
  • This paper deals with the lobby pressurization for smoke control in building fires. A computer program and related modeling technique are presented. The pressure difference between a lobby and a fire area is not able to be same among building floors because an injection fan can not be installed in each floor. The most remote area from the injection fan has therefore the smallest pressure difference if flow areas are not different through all floors. An adjacent floor from the injection fan has possibly too large pressure difference because the most remote lobby must also meet the required pressure difference over the fire area. Moreover this problem will lead to a larger capacity of the fan. It is showed that the fan capacity can be decreased by adjusting the flow area of air supply duct in each floor.

  • PDF

A Study on the Flow Changes around Building Construction Area Using a GIS Data (GIS 자료를 활용한 신축 건물 주변 지역의 흐름 변화 연구)

  • Mun, Da-Som;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.879-891
    • /
    • 2018
  • In this study, the effects of urban redevelopment and building construction on the change of the detailed flows around the Pukyong National University (PKNU) campus located in the building-congested area was investigated using a CFD (computational fluid dynamics) model and GIS (geographic information system). For the analysis of the detailed flows before and after the constructions of the buildings around and within the campus, numerical simulations for the 16 inflow directions were performed before and after the construction. We used, as reference wind speeds at the inflow boundaries, the averaged wind speeds observed at the Gwangan light beacon (962) where there is no surrounding obstacle (i.e., building and terrain) acting as friction. We analyzed the area fractions in which wind speeds at z = 2.5 m changed after the construction for 16 inflow directions. The area fractions were relatively large in the east-south-easterly and southerly cases, because of the high-rise buildings constructed at the east and the apartment complex and the Engineering buildings constructed at the south of the PKNU campus. In the case of the easterly of which frequency is highest among the wind directions observed at the Daeyeon AWS (AWS 942) located inside the PKNU campus, the wind-speed change was not significant even after the constructions. It is shown that the building construction has affected the detailed flows around as well as even in the far downwind region of the constructed buildings. Also, it is shown that the GIS and CFD model are useful for analyzing the detailed flows in planning the urban redevelopment and/or building construction.

An Analysis of Color Status and Image Evaluation of the Outdoor Advertisement for Improving the Outdoor Facade of Commercial Building Structure in Old Downtown Area (구도심가로변의 상업건축물 외부파사드 개선을 위한 옥외광고물의 색채현황 분석 및 이미지 평가)

  • Choi, Young-Sin;Lim, Che-Zinn;Lee, Jin-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.1
    • /
    • pp.208-219
    • /
    • 2011
  • This study is intended to formulate the issues through the status analysis and image evaluation for each street on the basis of colors for the outdoor advertisements for part of street side in the oldest downtown for its construction year. Analysing the business type of the street side, it displays the identity of the fashion business area and the color status shown on the outdoor advertisement did not consider the harmony on the other business type and building improvements that it displays chaotic street views in overall. Status of color for the outdoor advertisement compared and analyzed for each street-side to be analyzed with high color contrast with the building structure and outdoor advertisements than the Street B side where there are many businesses of fashion sundries and fashion clothes to form more complicated street scenery visually for the Street A side. The color combination principle of building structure and outdoor advertisement was shown to be the factor for the contrasting unity and diversity. In order not to stimulate this visual confusion, the colors of outdoor advertisement has to be applied on the basis of the color guideline based on the color combination principle of outdoor advertisement and building structure to have the aesthetic harmony overall. As a result of analysis using the KJ method, the present image of the old downtown area was shown with the adjective vocabularies of "complicated", "out-dated", "chaotic", "disorganized", "dirty", "suffocating", and "unilateral", and its image to strive for would be in a total of 6 adjective vocabularies of "well-arranged", "young", "dynamic", "sophisticated", "personable" and "neat", and it has presented the basic foundation of color guideline of outdoor advertisement fit for its image.

A Study on the Characteristics of Area and Spatial Elements Based on the Building Size of Childcare Center (보육시설 평면사례분석을 통한 시설규모별 소요실 및 면적특성 분석)

  • Park, Jung-A;Choi, Mock-Wha;Kim, Young-Aee
    • Journal of the Korean housing association
    • /
    • v.22 no.1
    • /
    • pp.65-73
    • /
    • 2011
  • The purpose of this study is to find out the characteristics of area and spatial elements according to the building size and provide the guidelines for space planning of the child care center. This study used the content analysis method and analysis was made on the floor plans for 51 cases and the floor plans were converted to Autocad drawings to analyze the area. The results of this study were as follows; 1) Child care centers over 70% were single-attached building types which made it possible for creating outdoor environments for children. However, most small-size centers which had under 50 children did not have the facilities for outdoor activities. 2) In terms of spatial elements, the basic spaces of the small-size center were the classroom, bathroom, kitchen, office and reference room. The medium or large size centers had extra rooms for special activities and service spaces in addition to the basic spaces. 3) Classroom area per child was 2.65 m2 on average. Space composition ratio on average for care, staff, and service was programmed by 57%, 9%, 34% respectively. Small-size center had relatively more care space when compared to the others. In the case of large-size centers, there was a tendency that service space was increased, but care space was decreased.

A re-examination of the current design rule for staggered bolted connections

  • Xue-Mei Lin;Michael C.H. Yam;Ke Ke;Binhui,Jiang;Qun He
    • Steel and Composite Structures
    • /
    • v.46 no.3
    • /
    • pp.403-416
    • /
    • 2023
  • This paper summarised and re-examined the theoretical basis of the commonly used design rule developed by Cochrane in the 1920s to consider staggered bolt holes in tension members, i.e., the s2/4g rule. The rule was derived assuming that the term two times the bolt hole diameter (2d0) in Cochrane's original equation could be neglected, and assuming a value of 0.5 for the fractional deduction of a staggered hole in assessing the net section area. Although the s2/4g rule generally provides good predictions of the staggered net section area, the above-mentioned assumptions used in developing the rule are doubtful, in particular for a connection with a small gauge-to-bolt-hole diameter (g/d0) ratio. It was found that the omission of 2d0 in Cochrane's original equation appreciably overestimates the net section area of a staggered bolted connection with a small g/d0 ratio. However, the assumed value of 0.5 for the fractional deduction of a staggered hole underestimates the staggered net section area for small g/d0 ratios. To improve the applicability of the above two assumptions, a modified design equation, which covers a full range of g/d0 ratio, was proposed to accurately predict the staggered net section area and was validated by the existing test data from the literature and numerical data derived from this study. Finally, a reliability analysis of the test and numerical data was conducted, and the results showed that the reliability of the modified design equation for evaluating the net section resistance of staggered bolted connections can be achieved with the partial factor of 1.25.