• Title/Summary/Keyword: building area

Search Result 3,915, Processing Time 0.026 seconds

A Study of Applications of DSM in tunnelling to an underground shopping-area (도심지 지하상가 연결통로 DSM(Divided Shield Method)공법 적용사례 연구)

  • Hong, Chang-Soo;Hwang, Dae-Jin;Lee, Kang-Ho;Cho, Keum-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.556-563
    • /
    • 2005
  • Recently, it is used to join an building to an underground shopping-area in urban. When we construct Seo-Cho Complex building which is in Seoul, we also construct an underground passage to the Gangnam underground shopping-area. But it is difficult to excavate in the downtown area, because excavations induce traffic jam and public discontent. Considering safety, a confined area, settlements, we decided to use DSM(Divided Shield Method) which is based on messer shield. This paper will produce our experience and the results provide a useful guide in a connection tunnel

  • PDF

A hierarchical plcement method for building block layout design (빌딩블록의 레이아웃 설계를 위한 계층적 배치 방법)

  • 강병익;이건배
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.11
    • /
    • pp.128-139
    • /
    • 1996
  • In this paper, we propose an algorithm to solve the problem of placement of rectangular blocks whose sizes and shpaes are pre-determined. The proposed method solves the placement of many retangular blocks of different sizes and shapes in a hierarchical manner, so as to minimize the chip area. The placement problem is divided into several sub-problems: hierarchical partioning, hierarchical area/shape estimation, hierarchical pattern pacement, overlap removal, and module rotation. After the circuit is recursively partitioned to build a hierarchy tree, the necessary wiring area and module shpaes are estimated using the resutls of the partitioning and the pin information before the placement is performed. The placement templaes are defined to represent the relative positions of the modules. The area and the connectivity are optimized separately at each level of hierachy using the placement templates, so the minimization of chip area and wire length can be achieved in a short execution time. Experiments are made on the MCNC building block benchmark circuits and the results are compared with those of other published methods. The proposed technique is shown to produce good figures in tems of execution time and chip area.

  • PDF

Calculation of the Area of Vulnerability to Voltage Sags by using Impedance Building Algorithm (임피던스 행렬 구성법을 이용한 순간전압강하 취약지역의 계산)

  • Park, Jong-Il;Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.44-53
    • /
    • 2012
  • This paper presents a method to calculate the area of vulnerability by using the impedance building algorithm. The installation of DG (Distributed Generation) is one of the countermeasures against voltage sags in power systems. In order to estimate the effect of the DG, the voltage sag assessment should be performed based on the area of vulnerability and system fault statistics. To determine the area of vulnerability, system impedance matrix should be calculated. The calculation of the impedance matrix of large systems is time-consuming task. This paper addresses an effective scheme to calculate the area of vulnerability and system impedance matrix.

Optimum Design of Dye-Sensitized Solar Module for Building-Integrated Photovoltaic Systems

  • Lee, Kyu-Seok;Kang, Man Gu
    • ETRI Journal
    • /
    • v.39 no.6
    • /
    • pp.859-865
    • /
    • 2017
  • This paper presents a method for determining the optimum active-area width (OAW) of solar cells in a module architecture. The current density-voltage curve of a reference cell with a narrow active-area width is used to reproduce the current density profile in the test cell whose active area width is to be optimized. We obtained self-consistent current density and electric potential profiles from iterative calculations of both properties, considering the distributed resistance of the contact layers. Further, we determined the OAW that yields the maximum efficiency by calculating efficiency as a function of the active-area width. The proposed method can be applied to the design of the active area of a dye-sensitized solar cell in Z-type series connection modules for indoor and building-integrated photovoltaic systems. Our calculations predicted that OAW increases as the sheet resistances of the contact layers and the intensity of light decrease.

Analysis on the Characteristics of Activity Areas in Classrooms of Childcare Centers Depending on Age Groups (어린이집 사례분석에 의한 연령별 보육실의 흥미영역 특성분석)

  • Park, Jung-A;Choi, Mock-Wha
    • Journal of the Korean housing association
    • /
    • v.23 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study is to find out the characteristics of activity areas according to the age difference and provide the alternatives for space planning of activity areas in classroom of childcare centers. This study used the content analysis method for field survey data collected from 36 classrooms of 9 childcare centers in the Daejeon area. Floor plans were converted to Autocad drawings to analyze the characteristics of activity areas. The results of this study were as follows; 1) In case of 0 to 2-year-old classrooms, they had 6 activity areas such as gross-motor area, role play, block building, language, creative expression, exploration/manipulation area. The activity area with the most low frequency was gross-motor area. 2) In case of 0 to 2-year-old classrooms, the size of activity area was in order of gross-motor area > role play > block building > language > creative expression > exploration/manipulation area. In case of 3 to 5-year-old classrooms, the size of activity area was in order of language > art > role play > math > block building > science > tone and rhythmic area. 3) The central areas with easy access in 0 to 2-year-old classrooms were Large-motor and Imaginary Play Areas. Also, more isolated areas were Manupulatives and Block Areas. The central areas with easy access in 3 to 5-year-old classrooms were Arts, Numbers and Manupulatives. While more isolated areas were Music, Movement and Science Areas.

Analysis about Biotope Area Ratio of New Town Housing Complex in the Metropolitan Area of Korea (우리나라 수도권 신도시 주거단지의 생태면적률 분석)

  • Oh, Choong-Hyeon;Kim, Han-Soo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.4 s.117
    • /
    • pp.105-115
    • /
    • 2006
  • Biotope Area Ratio ($BFF; BiotopFl{\"{a}}chenFaktor$) was developed in Berlin, Germany in 1990s and introduced to Korea in 1999. It is the ratio of the uncovered soil areas which have the natural circulating capability compared to whole development areas. This study seeks for alternative ways to increase Biotope Area Ratio of residential areas in the metropolitan areas of Korea by investigation on new housing developments. The study investigates four new towns including Seoul Eunpyung new town, Yongin Kusung district, Goyang Pungdong and Juyeopdong districts and Hwasung Dongtan district. The Biotope Area Ratio of study sites is between 23.51 % and 40.69%. This result is not relevant to land use conditions, such as the building-ta-land ratio, natural ground green area ratio. This ratio satisfies the minimum requirements of City of Seoul, except 2 sites. Considering that the study sites are relatively low density land use areas compared to Seoul's average, thus, a higher standards is necessary for new town housing complexes. Because Biotope Area Ratio includes artificial ground green area ratio, Biotope Area Ratio is possible can be increased with decreased natural ground green area ratio. And so, when Biotope Area Ratio is applied to new town development, it must go side by side with a definite natural ground green area ratio.

Application of Seismic Isolation Technique in Residential-Commercial Building (주상복합건물에 대한 면진기술의 적용)

  • 이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.465-472
    • /
    • 2000
  • Seismic isolation technique has been applied mainly in low rise buildings and its seismic performance was satisfactory during Kobe Earthquake. However, in the case of medium and/or high-rise buildings, mid-story isolation could be more technically feasible than base isolation to reduce earthquake forces. In this paper, the seismic effectiveness of mid-story isolation in medium and/or high-rise shear building as well as low rise shear building was evaluated analytically. After verifying the effectiveness of mid-story isolation technique, this method also applied in residential-commercial building. It was found that mid-story isolation, that is isolation between upper residential area and lower commercial area, could reduce inter-story drift and floor shear forces comparing to the conventional fixed base.

  • PDF

A Study on Related System of Building Greening in Japan (일본의 건축물 녹화 관련제도 연구)

  • Yoon, Yong-Han;Ju, Jin-Hee;Kim, Won-Tae
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1397-1402
    • /
    • 2010
  • In recently, building greening to improve the urban environment is a very important areas. Thus, in order to promote the building greening is needed for the arrangement of its related system. In this study, analyzed the related system in Japan and the results obtained are as follows. Related system in Japan are to promote the spread of compulsory and dissemination of guidance. And to promote the spread of dissemination of guidance are to allowed a system to be included in green area of the site required, plans to loan the costs of greening, plans to subsidize the cost of greening, tax reduction and exemption, incentive on floor area ratio, plant supply and other technical guidance system. In conclusion, in order to promote the building greening note the related system of Japan and our related system should be arranged.

A Study on Realization Method of Low Carbon School Building (저 탄소 학교건축물 구현 방안에 관한 연구)

  • Tae, Sung-Ho;Cho, Young-Sang;Shin, Sung-Woo;Lee, Seung-Min;Meang, Joon-Ho
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.9 no.2
    • /
    • pp.30-37
    • /
    • 2010
  • This study purposed realization and a phase reduction of school building $CO_2$ emissions. Accordingly selected standard school buildings and evaluated life cycle environmental load($CO_2$). This study proposed Green building technology which separated design sector, energy sector, afforestation sector for carbon-neutral city school buildings realization of M-city. As a result, elementary, middle and high schools of M-city built in the year 2013 were required that design sector was Energy Performance Index(EPI) 75 point and energy sector was solar installations more than 25% of the power usage, Solar systems installed more than 10% of total gas consumption and the area of afforesting more than 35% of the ecological area to achieve 30% $CO_2$ reduction compared to the Respectively standard school buildings.

Overshadowing Analysis of Apartment Building Arrangement with a Average Shading Ratio (음영면적비를 이용한 공동주택의 단위세대별 일조환경 평가연구)

  • Yoon, Jong-Ho;Yeo, Seung-Ki;Park, Jae-Sung;Lee, Si-Woong;Chin, Kyung-Il
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.35-42
    • /
    • 2006
  • This study is to investigate the possibility of a quantitative analysis on sunshine right in apartment houses with a new evaluation index of shading area ratio(SAR) which represents seasonal average value of shaded portion of a window during definite period. SAR values of each apartment houses in a prototype building was calculated depending on apartment building arrangement types and orientations. Since the new method proposed in this research is able to measure the sunshine possibility of the each house in detail, which is more precise and descriptive than the existing method of sunshine judgment standard based on the sunshine hours only at winter solstice, it can be appropriately utilized as a highly qualified sunshine right judgment measures in apartment buildings.