Seismic Design of Buckling-Restrained Braced frame Using Equivalent Energy Concept (등가 에너지 개념을 이용한 비좌굴 가새골조의 내진설계)

  • 김진구;최현훈;원영섭
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.47-55
    • /
    • 2003
  • This study proposed a convenient seismic design procedure for buckling-restrained braced frames based on the equivalent energy concept. The design process begins with the computation of input energy from response spectrum. Then the elastic energy and plastic energy are computed based on the equal energy concept. The computed plastic energy is distributed to each story along energy distribution ratio and the cross-sectional area of each brace is computed so that all the plastic energy is dissipated by the brace. The proposed procedure was applied to the design of three-, six-, and twenty-story steel frames with buckling-restrained braces, and artificial earthquake records were used for verification of the proposed method. According to analysis results, top story displacements of the low-rise structure satisfies the given target displacement however that of the twenty-story structure was much smaller than the given target displacement.

Inelastic Buckling Analysis of Partially Restrained Frame (유연 뼈대 구조물의 비탄성 좌굴 해석)

  • Kim Seung Eock
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.19-28
    • /
    • 1996
  • 본 논문에서는 유연 연결부를 갖고 있는 이차원 구조물의 비탄성 좌굴해석을 연구하였다. 본 해석을 통하여 구조물의 기하학적, 및 재료적 비선형 뿐만 아니라 유연 연결부의 비선형 효과가 구조물의 거동과 강도에 미치는 영향을 예측할 수 있다. 본 해석 결과는 실험 결과와 비교하였으며 예제해석도 수행하였다.

  • PDF

Simplified Algorithm of the Novel Steel-concrete Mixed Structure under Lateral Load

  • Li, Liang;Li, Guo-qiang;Liu, Yu-shu
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.4
    • /
    • pp.247-254
    • /
    • 2012
  • In order to improve the seismic behaviors of traditional steel-concrete mixed structure, a novel steel concrete mixed structure consisting of steel frames braced with buckling restrained braces (BRBs) and a concrete tube is proposed. Based on several assumptions, the simplified mechanical model of the novel mixed structure is established, and the shear and bending stiffness formulas of the steel frames, BRBs and concrete tube are respectively introduced. The equilibrium differential equation of the novel mixed structure under horizontal load is developed based on the structural elastic theory. The simplified algorithms to determine the lateral displacement and internal forces of the novel mixed structure under the inverted-triangle distributed load, uniformly load and top-concentrated load are then obtained considering several boundary conditions and compatible deformation conditions. The effectiveness of the simplified algorithms is verified by FEM comparison.

Seismic performance evaluation of buckling restrained braced frames (BRBF) using incremental nonlinear dynamic analysis method (IDA)

  • Khorami, M.;Khorami, M.;Alvansazyazdi, M.;Shariati, M.;Zandi, Y.;Jalali, A.;Tahir, M.M.
    • Earthquakes and Structures
    • /
    • v.13 no.6
    • /
    • pp.531-538
    • /
    • 2017
  • In this paper, the seismic behavior of BRBF structures is studied and compared with special concentric braced frames (SCBF). To this purpose, three BRBF and three SCBF structures with 3, 5 and 10 stories are designed based on AISC360-5 and modelled using OpenSees. These structures are loaded in accordance with ASCE/SEI 7-10. Incremental nonlinear dynamic analysis (IDA) are performed on these structures for 28 different accelerograms and the median IDA curves are used to compare seismic capacity of these two systems. Results obtained, indicates that BRBF systems provide higher capacity for the target performance level in comparison with SCBF systems. And structures with high altitude (in this study, 5 and 10 stories) with the possibility of exceeding the collapse prevention performance level, further than lower altitude (here 3 floors) structures.

Lateral Buckling Analysis of the Thin-Walled Space Frame (박벽(薄壁) 공간(空間)뼈대구조(構造)의 횡좌굴(橫挫屈) 해석(解析))

  • Kim, Moon Young;Shin, Hyun Mock
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.13-24
    • /
    • 1993
  • The tangent stiffness matrices of the plane frame and the thin-walled space frame are derived by using the principle of virtual displacement. In case of the plane frame, the shape function and stiffness matrices are presented for the rigid-hinged condition. For the unsymmetric thin-walled space frame, the elastic and geometric stiffness matrices in three cases of the unrestrained torsion, the restrained torsion, and the restrained anti unrestrained torsion are evaluated by using the various Hermitian polynomials as the shape function. Numerical examples for the lateral buckling analysis of the space frames and the circular arch illustrate the accuracy and convergence characteristics of the derived formulations.

  • PDF

Experimental Study on Buckling Restrained Knee Bracing Systems using Channel Scetions (채널 형강을 이용한 비좌굴 Knee Bracing System의 내진성능에 대한 실험적 연구)

  • Lee, Jin;Lee, Ki Hak;Lee, Han Seon;Kim, Hee Cheul;Lee, Young Hak
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.71-81
    • /
    • 2009
  • In this study, the seismic performance of the Buckling Restrained Knee Bracing (BRKB) system was evaluated through a pin-connected one-bay, one-story frame. The BRKB system developed in this study was composed of a steel plate as a load-resisting core member and two channel sections to restrain local and global buckling of the core plate. The main purpose of the BRKB system is to restrengthen/rehabilitate old low- and mid-rise RC buildings, which, it is assumed, were designed with non-seismic designs and details. The main variables for the test specimens were the size of the core plates and the stiffeners, and the condition of the end plates. The test results showed that the size of the core plate, which was the main element of the load-resisting member, was the most important parameter in achieving a ductile behavior under tension as well as compression until the maximum displacement exceeds twice the design drift limit.

Storey-based stability analysis of multi-storey unbraced frames

  • Liu, Y.;Xu, L.
    • Structural Engineering and Mechanics
    • /
    • v.19 no.6
    • /
    • pp.679-705
    • /
    • 2005
  • This paper presents a practical method to evaluate the effective length factors for columns in multi-storey unbraced frames based on the concept of storey-based elastic buckling by means of decomposing a multi-storey frame into a series of single-storey partially-restrained (PR) frames. The lateral stiffness of the multi-storey unbraced frame is derived and expressed as the product of the lateral stiffness of each storey. Thus, the stability analysis for the multi-storey frame is conducted by investigating the lateral stability of each individual storey, which is facilitated through decomposing the multi-storey frame into a series of single-storey PR frames and applying the storey-based stability analysis proposed by the authors (Xu and Liu 2002) for each single-storey PR frame. Prior to introducing decomposition approaches, the end rotational stiffness of an axially load column is derived and rotational stiffness interaction between the upper and lower columns is investigated. Three decomposition approaches, characterized by means of distributing beam-to-column rotational-restraining stiffness between the upper and lower columns, are proposed. The procedure of calculating storey-based column effective length factors is presented. Numerical examples are then given to illustrate the effectiveness of the proposed procedure.

Seismic Retrofit of Reinforced Concrete Structures Using Steel Braces and Moment Frames (가새와 강골조를 이용한 저층 RC 구조물의 내진보강)

  • Huynh, Chanh Trung;Park, Kyoung-Hoon;Kim, Jin-Koo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.509-516
    • /
    • 2010
  • In this study a seismic retrofit scheme for the reinforced concrete moment framed structures was investigated using steel bracing and moment frames. The analysis model structure is a 3-story 3-bay moment frame structure designed only for gravity load. The stress/strain concentration in brace-RC frame connection was investigated using finite element analysis. To prevent premature joint failure, steel moment frames were placed inside of middle bay of the RC frame. Two types of braces, steel braces and buckling restrained braces(BRBs), were used for retrofit, and the ductility and the strength of the structure before and after the retrofit were compared using nonlinear static and dynamic analyses. According to the analysis results, the strength and ductility of the structure retrofitted by the moment frames and braces increased significantly. The added steel frame did not contribute significantly to the increase of lateral strength mainly because the size is relatively small.

Enhancing the Seismic Performance of Multi-storey Buildings with a Modular Tied Braced Frame System with Added Energy Dissipating Devices

  • Tremblay, R.;Chen, L.;Tirca, L.
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.21-33
    • /
    • 2014
  • The tied braced frame (TBF) system was developed to achieve uniform seismic inelastic demand along the height of multi-storey eccentrically braced steel frames. A modular tied braced frame (M-TBF) configuration has been recently proposed to reach the same objective while reducing the large axial force demand imposed on the vertical tie members connecting the link beams together in TBFs. M-TBFs may however experience variations in storey drifts at levels where the ties have been removed to form the modules. In this paper, the possibility of reducing the discontinuity in displacement response of a 16-storey M-TBF structure by introducing energy dissipating (ED) devices between the modules is examined. Two M-TBF configurations are investigated: an M-TBF with two 8-storey modules and an M-TBF with four 4-storey modules. Three types of ED devices are studied: friction dampers (FD), buckling restrained bracing (BRB) members and self-centering energy dissipative (SCED) members. The ED devices were sized such that no additional force demand was imposed on the discontinuous tie members. Nonlinear response history analysis showed that all three ED systems can be used to reduce discontinuities in storey drifts of M-TBFs. The BRB members experienced the smallest peak deformations whereas minimum residual deformations were obtained with the SCED devices.