• Title/Summary/Keyword: brush

Search Result 758, Processing Time 0.026 seconds

In Vitro Study on the Artificial Plaque Removal Effect by Use of 360 Degree Rotating Head with Sonic Tooth-Brush

  • Lim, Jee-Hyun;Kim, Jin-Sil;Choi, Hwa-Young
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.228-234
    • /
    • 2018
  • Objective: The authors have experimented for the artificial plaque removal effect of several kinds of 360 degree rotating head typed tooth-brushes with sonic vibratory actioned by using of automatic machine for horizontal scrub method in order to find the better toothbrush type for plaque removal. Methods: The experiment was conducted on three medium to 360 degree rotating head toothbrushes, a medium sized toothbrush and a medium sized toothbrush, and a flat toothbrush consisting of 30 ordinary toothbrushes. A brushing machine with horizontal scrubbing was manufactured and had variations of the end of the bristle attached to or near the surface of the teeth, a vibrating wave action force of 16,000 or 18,000 cycles per minute, and a working time of 2 or 3 minutes. The tooth removal effect was confirmed by scanning and analyzing images with a computer program after automatic brushing with the machine. The elimination rate results for each group were analyzed using the independent t-test and one-way ANOVA test. Results: It revealed the most in removal effect for the artificial plaque in such conditions as action at near the tooth surface with 18,000 cycle for 3 minutes in case of using A, B, and C tooth-brush. And it has more removal effect rate than for using the plane tooth-brush (p<0.05). Conclusion: It was recommended to develop the 360 degree rotating head and vibratory toothbrush focusing to use near the tooth surface with 18,000 cycles of vibration for 3 minutes at one site of the teeth area.

Efficacy of a novel channel-cleaning ball brush for endoscope reprocessing: a randomized controlled trial

  • Kwang Hyun Chung;Jeong Don Chae;Wonho Choe;Hyo Young Lee;Il Hwan Oh;Byoung Kwan Son
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.674-682
    • /
    • 2022
  • Background/Aims: Endoscopic channels are difficult to clean and can cause infection transmission. We examined the effectiveness of a newly developed channel-cleaning ball brush (BB), which is sucked into the endoscopic channel and scrapes and cleans the lumen as it passes through. Methods: The upper and lower gastrointestinal endoscopes used for patient examinations were randomly selected as the conventional brush (CB) or BB group. After manual cleaning, the presence or absence of carbohydrates, proteins, adenosine triphosphate, and hemoglobin was assessed. Results: Fifty-six and 58 endoscopes were cleaned with the CB and BB, respectively. Carbohydrate and protein were detected in one (1.8%) and two endoscopes (3.4%) in the CB and BB groups, respectively (p=1.000). Hemoglobin was observed in one (1.8%) and three endoscopes (5.2%) in the CB and BB groups, respectively (p=0.636). The adenosine triphosphate levels were 10.6±15.9 and 12.5±14.3 relative light units in the CB and BB groups, respectively (p=0.496). Twenty-seven (48.2%) and 19 (32.8%) endoscopes were positive for microbial cultures in the CB and BB groups, respectively (p=0.136). Conclusions: The efficacy of BB was not significantly different from that of CB in the endoscopic channel-cleaning process.

A Study on the Starter Control of the Turbo Generator (터보 제너레이터의 시동기 제어에 관한 연구)

  • 박승엽;노민식
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.286-293
    • /
    • 2004
  • This paper presents the result of a study on the starter control for a turbo generator. Because a starter in gear box type turbo-generator system is composed of gearbox and brush DC motor, it should be replaced with High Speed Generator(HSG)) in HSG type Turbo-generator. There-ore, it is necessary to design a new starting algorithm and starter. In gearbox type system, brush DC motor is rotated to the designed speed using low voltage-high current battery power. After brush DC motor speed is increased to several times by gearbox, gas turbine engine can be rotated to designed starting speed. If we implement a starter with High Speed Generator(HSG), it is necessary to drive high-speed generator to high-speed motor. High-speed generator with permanent magnet on rotor has a low leakage inductance fur driving high-speed rotation, and it is necessary high DC link voltage for inverter when High-speed generator is driven to high speed. This paper presents result of development of the boost converter for converting high voltage DC from low battery voltage and design of the inverter for controlling a high frequency current to be injected to motor winding. Also, we show performance of the designed starter by driving the turbo generator.

Comparison of Equipment Contamination Level according to Enteral Nutrition Bag Cleaning and Disinfection Methods (경장영양백 세척 및 소독방법에 따른 오염 정도 비교)

  • Park, Jin-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.4
    • /
    • pp.472-479
    • /
    • 2011
  • Purpose: The purpose of this study was to develop guidelines for cleaning of enteral nutrition bags by comparing the level of equipment contamination according to cleaning and disinfection methods. Method: This study was a true-experimental study, with 60 cases in total. Twenty cases each were randomly assigned to tepid water, detergent and brush, and disinfectant groups. The period of the experiment was March to April 2010, and enteral nutrition was given for 1 houre, 3 times a day at 7AM, noon, and 7PM for seven days. Enteral nutrition bags were cleaned after each feeding according to assigned cleaning and disinfection method followed by microbial cultures on 4th and 8th day before the 7AM feeding. Results: After 3 days of feeding and cleaning, the level of contamination of bags was not significantly different among the three groups. After seven days, the level of contamination was significantly lower when bags were cleaned with detergent and brush or with disinfectant compared to cleaning with tepid water. Conclusion: In cases where enteral nutrition bags are reused for example, in home care settings, studying findings indicate that cleaning bags using detergent and brush or disinfectant is an effective way to prevent contamination of bags.

The Development of PC based Ink-and-wash Drawing System Using Wiimote (위모트를 이용한 PC 기반 수묵화적 드로잉 시스템 개발)

  • Oh, Eun-Byol;Ryoo, Seung-Taek
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.4
    • /
    • pp.1-10
    • /
    • 2011
  • The general technique of ink-and-wash drawing consists of brush, ink and paper modeling and brush movement, ink diffusion and paper material simulation. In this paper, we suggest the simplified Qing's tank model that can decrease the computational time of ink diffusion and absorption on korean paper. The suggested drawing system is classified the characteristics of ink-and-wash into ink-shade, diffusion, line and paper. Also, the user's movement using motion sensor and IR sensor in wiimote is transmitted to brush position and direction.

Conservation and Restoration of Bamboo Brush Stand with Carved Design (죽제조문필통(竹製彫文筆筒)의 보존과 복원)

  • Son, Jongmin;Yi, Yonghee
    • Conservation Science in Museum
    • /
    • v.10
    • /
    • pp.21-27
    • /
    • 2009
  • This bamboo brush stand was made by attaching two bamboo tubes together, each 80mm in diameter. On the bottom is a "∞-shaped"wood board made of Ailanthus altissima. The surfaces are decorated with exquisite and dynamic designs of a dragon and clouds, and a deer and pine trees. Part of this bamboo brush stand was damaged, lost, or worn down, prior to conservation treatment. After conservation and recovery treatment, its original form was restored. Earth powder, chalk, and gluten mixture were used as materials to fill in the missing parts. After the original form was restored, thin silk fabric was attached to the inner surface of the glued part to prevent cracking. Traditional materials and repair techniques were used to allow for reversal of treatment, if necessary, as seen in the surface of the restored part being made antiquated with lacquer varnish.

Phase Advance Control to Reduce Torque Ripple of Brush-less DC Motor According to Winding Connection, Wye and Delta

  • Lee, Tae-Yong;Song, Jun-Young;Kim, Jaehong;Kim, Yong-Jae;Jung, Sang-Yong;Je, Jung-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2201-2208
    • /
    • 2014
  • In this research, the characteristics of Brush-less DC (BLDC) motor in accordance with winding connection method, both Y-connection and D -connection, has been identified with design methodology simply. BLDC motor has been designed for both winding connections, and their torque analysis has been performed considering ideal current source analysis and voltage source analysis with 6-step control. In addition, to reduce torque ripple of BLDC motor, caused by coil inductance, on voltage source analysis with 6-step control, we have proposed suitable control method which is Phase Advance Control. It is verified that the torque ripple has been decreased by virtue of phase advance control, advancing and widening conduction angle of switching, via performance analysis by Finite Element Analysis.

Effects of D-Fructose on the Uptake of Iron by the Intestinal Brush-Border Membrane Vesicles from Rats.

  • Kim, Ok-Seon;Lee, Yong-Bok;Oh, In-Joon;Koh, Ik-Bae;Lee, Yeong-Woo
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.11-18
    • /
    • 1994
  • We have studied the iron uptake by the purified brush-border membrane vesicles (BBMVs) to determine the effect of fructose on the absorption of iron. BBMVs were prepared by the modified calcium precipitation method, The degree of purification was routinely assessed by the marker enzyme, alkaline phosphatase, and the functional integrity was tested by $D-[1-^3H]glucose$ uptake. The appearance of membrane vesicles was shown by transmission electron microscopy (TEM). The uptakes of complexes of labeled iron $[^{59}Fe]$ with fructose and ascorbate were measured with a rapid filtration technique, The uptake rate and pattern of the two iron-complexes, Fe(III)-fructose and Fe(III)-ascorbate, were also observed. A typical overshooting uptake of D-glucose was observed with peak value of $2{\sim}3$ times higher concentration than that at equilibrium. This result was similar to other studies with BBMVs. TEM showed that the size of BBMVs was uniform and we can hardly find any contaminants, Fe(III)-fructose has the higher value of $V_{max}$ and the lower value of Km than those of Fe(III)-ascorbate, respectively. It may be concluded that D-fructose is more effective in promoting the iron absorption than ascorbate.

  • PDF

Kinetics of Organic ion Transport Across Rabbit Renal Brush Border and Basolateral Membrane Vesicles (가토 신피질 Brush Border Membrane과 Basolateral Membrane Vesicle에서 유기이온의 이동에 대한 동력학적 분석)

  • Kim, Yong-Keun;Woo, Jae-Suk;Lee, Sang-Ho
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.273-282
    • /
    • 1987
  • 가토 신피질에서 분리한 brush border membrane (BBM)과 basolateral membrane vesicle (BLM)에서 유기 음이온인 p-aminohippuric acid (PAH)와 유기 양이온인 tetraethylammonium (TEA)의 이동에 대한 동력학적 분석을 하였다. BLM에서 PAH에 대한 Km과 Vmax값은 각각 $0.34{\pm}0.02\;mM$$0.22{\pm}0.07\;nmol/mg\;protein/20s$였으며 BBM에서 각 값은 $8.46{\pm}0.57\;mM$$4.43{\pm}0.40\;nmol/mg\;protein/20s$였다. BLM에서 용액내 Na의 제거는 PAH에 대한 Km 값에는 영향없이 Vmax 값을 변화시켰다. BBM에서 TEA이동에 대한 Km과 Vmax 값은 각각 $0.55{\pm}0.15\;mM$$1.04{\pm}0.23\;nmol/mg\;protein/20s$였으며 BLM에서 각 값은 $0.46{\pm}0.04\;mM$$0.61{\pm}0.06\;nmol/mg\;protein/20s$였다. BLM에서 측정한 유기 이온들의 이동에 대한 Km 값이 신절편이나 분리된 tubule에서 보고된 값과 일치함을 보였으며 이러한 결과는 신세뇨관 세포막을 통한 유기 이온들의 이동 특성이 membrane vesicle을 분리하는 과정에서 변하지 않았음을 가르킨다.

  • PDF

Inhibition of Dicarboxylate Transport by p-chloromercuribenzoic Acid (PCMB) in Plasma Membrane Vesicles of Rabbit Proximal Tubule

  • Kim, Yong-Keun;Kim, Tae-In;Jung, Jin-Sup;Lee, Sang-Ho
    • The Korean Journal of Physiology
    • /
    • v.25 no.2
    • /
    • pp.179-188
    • /
    • 1991
  • Effect of a sulfhydryl reagent, p-chloromercuribenzoic acid (PCMB), on the transport of succinate was studied in brush border (BBMV) and basolateral (BLMV) membrane vesicles isolated from rabbit renal cortex. PCMB induced an irreversible inhibition of the $Na^+-dependent$ succinate uptake in a dose-dependent manner with $IC_{50}$ of 55 and $65\;{\mu}M$ in BBMV and BLMV, respectively. The inhibitory effect of PCMB was prevented by a pretreatment of vesicles with dithiothreitol. PCMB did not increase $Na^+$ permeability at concentrations inhibiting succinate uptake. The PCMB inhibition of succinate uptake was due to a change in Vmax, but not in Km. When membrane vesicles were pretreated with PCMB in the presence of unlabelled succinate, the inhibitory effect was significantly reduced. In both BBMV and BLMV, succinate uptake was inhibited by various sulfhydryl reagents with the inhibitory potency of following order: $HgCl_2$>DTNB>PCMBS>PCMB. These results suggest that sulfhydryl groups are essential for dicarboxylate transport and that they may be located at or near substrate binding sites of the transporters in renal brush border and basolateral membranes.

  • PDF