• 제목/요약/키워드: brittle failure

검색결과 588건 처리시간 0.025초

Failure characteristics and mechanical mechanism of study on red sandstone with combined defects

  • Chen, Bing;Xia, Zhiguo;Xu, Yadong;Liu, Shuai;Liu, Xingzong
    • Geomechanics and Engineering
    • /
    • 제24권2호
    • /
    • pp.179-191
    • /
    • 2021
  • In this study, the strength and failure mechanism of red sandstones with combined defects were investigated by uniaxial compression tests on red sandstones with different crack angles using two-dimensional particle flow code numerical software, and their mechanical parameters and failure process were studied and analyzed. The results showed that the mechanical characteristics such as peak strength, peak strain, and elastic modulus of the samples with prefabricated combined defects were significantly inferior than those of the intact samples. With increasing crack angle from 15° to 60°, the weakening area of cracks increased, elastic modulus, peak strength, and peak strain gradually reduced, the total number of cracks increased, and more strain energy was released. In addition, the samples underwent initial brittle failure to plastic failure stage, and the failure form was more significant, leading to peeling phenomenon. However, with increasing crack angle from 75° to 90°, the crack-hole combination shared the stress concentration at the tip of the crack-crack combination, resulted in a gradual increase in elastic modulus, peak strain and peak strength, but a decrease in the number of total cracks, the release of strain energy reduced, the plastic failure state weakened, and the spalling phenomenon slowed down. On this basis, the samples with 30° and 45° crack-crack combination were selected for further experimental investigation. Through comparative analysis between the experimental and simulation results, the failure strength and final failure mode with cracks propagation of samples were found to be relatively similar.

기존 원형교각의 내진성능 향상을 위한 FRP 보강에 대한 이론적 연구 (A Theoretical Study on the FRP Retrofit of Existing Circular Bridge Piers for Seismic Performance Enhancement)

  • 권태규;최영민;황윤국;윤순종
    • 콘크리트학회논문집
    • /
    • 제16권1호
    • /
    • pp.61-69
    • /
    • 2004
  • 신설교량의 경우 최근 개정된 도로교설계기준에 의해 내진설계를 수행하여 시공되었으나, 내진설계규정이 적용되기 이전에 시공되어 사용중에 있는 철근콘크리트 교각의 경우에는 지진에 의한 횡하중에 대해 취약할 수 있다. 특히 형상비가 큰 기존 교각에서는 기초와 교각 접합부에 주철근 겹침이음이 존재하므로 지진이 발생할 경우 피복콘크리트 파손에 따른 부착파괴 형태의 급격한 취성파괴 거동을 나타낸다. 이러한 부착파괴가 일어나는 소성힌지 구간에 FRP 적층 원통관으로 보강하여 부착강도를 크게 함으로써 횡하중에 대한 급격한 파괴를 예방할 수 있다. 따라서 본 연구에서는 FRP 적층 원통관으로 보강된 원형교각에서 FRP 적층 원통관이 주는 구속효과를 효과적으로 산정하기 위한 이론식을 유도하여 제안하고자 하였다. 이를 위해 FRP 적층 원통관이 철근콘크리트 원형교각에 발생시키는 구속응력을 이론적으로 유도하여 제안하였으며, 제안된 식의 타당성을 검증하기 위해 기존의 타 연구에서 수행한 실험결과와 비교, 검토하였다. 또한 다양한 FRP 적층조건에 따른 구속응력의 변화를 고찰하기 위한 매개변수 연구를 수행하였다. 이와 같은 연구를 통해 본 연구에서 제안하는 식이 FRP 적층 원통관을 이용하여 보강한 기존 원형교각의 거동을 잘 예측할 수 있음을 확인하였으며, 적층수, 섬유배향각, 섬유방향의 탄성계수가 FRP 적층 원통관에 의한 내진보강효과에 가장 지배적인 매개인자임을 알 수가 있었다.

다양한 전단보강근비를 가진 RC보의 화재노출시간에 따른 강도변화 (Strength of RC Beam with Various Shear Reinforcement Ratios After Experiencing Different Duration of Fire Load)

  • 서수연;정채명;최기봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.188-197
    • /
    • 2010
  • 본 연구에서는 전단보강근 비율이 다양한 철근콘크리트 보에 대하여 가열시간을 각각 달리한 후 그 구조성능변화를 실험적으로 연구하였다. 또한 기존의 기준에서 적용하고 있는 부재의 내력산정방법에 대한 검증을 통하여 화재손상된 철근콘크리트 강도예측을 위한 자료를 제공하고자 한다. 이를 위하여 9개의 철근콘크리트 보를 제작하여 표준가열곡선에 따라 가열로에서 가열시험을 실시하고, 이들 손상된 보에 대한 파괴실험을 통하여 구조성능의 변화를 관찰하였다. 또한 부재와 동일한 피복을 가진 철근에 대하여 가열후 철근강도변화를 관찰하여 가열에 따른 철근의 물성변화를 파악하였다. ACI기준과 Eurocode 기준을 분석하고 실험결과와의 비교를 통하여 화재손상된 RC부재의 구조성능변화를 평가하였다. 연구결과, 1시간과 2시간 가열된 실험체가 무가열실험체들에 비하여 매우 취성적인 파괴양상을 보였고, 이러한 양상은 전단 보강근비가 작아질수록 그리고 가열시간이 증가할 수록 심하게 나타났으며, 화재에 의한 재료손상의 정확한 예측이 가능할 경우, 부재의 구조성능변화는 충분히 평가가능한 것으로 나타났다.

플랫 플레이트-기둥의 외부 접합부의 변수 연구 (Numerical study on parameters of flat plate-column edge connections)

  • 안귀용;최경규;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.173-178
    • /
    • 2002
  • Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column edge connection. In the present study, numerical studies were performed for edge connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, drift, effective width around the connection were investigated. Based on tile findings of the numerical studies, the disadvantages of current design methods were discussed.

  • PDF

국산 저이완 PS 강연선의 피로특성에 관한 연구 (A Study on Fatigue Characteristics of Domestic Low-Relaxation PS Strands)

  • 변근주;송하원;박상순;노병철
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.113-119
    • /
    • 1999
  • Fatigue failure is a phenomenon such that structures under cyclic service load is failed by sudden brittle manner. Therefore, in order to obtain structures safety against the fatigue failure during their service lifes, fatigue characteristics should be considered for design and analysis of the structures. As stress range of prestressed (PS) tendons, which governs fatigus characteristic of prestressed concrete (PSC) structures, increases with increased use of partial prestressig, it is more necessary to consider fatigue characteristics of PS tendons. In this paper, direct-tension fatigue experiments with special specimen-setting devices are carried out to obtain fatigue characteristics of domestic low relaxation PS strands having different diameters and PS strands connected with coupler. Then, allowable stress range of fatigue for PSC beams using low relaxation strands are presented for the fatigue examination of prestressed concrete beams applied cyclic loading.

고강도와 보통 강도 콘크리트를 사용한 보-기둥 접합부의 휨강성화에 따른 이력거동 (The Effect of The Flexural Strength Ratio on Beam-Column Joint with High and Low Strength Concrete)

  • 신성우;안종문;문정일;김대근;이광수;박희민;이승훈;오정근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.185-190
    • /
    • 1992
  • ACI318-89 Recommended that when the specified compressive strength of concrete in a column is greater than1.4 times that specified for a floor system, top surface of the column concrete shall extend 2ft(600mm)into the slab from the face of column to avoid unexpected brittle failure. The major variables are extension distance, flexural strength ratio(Mr), and shear reinforcement ratio(Vs). Test results are as follows ; (1) The failure modes of specimens under cyclic loading were concentrated at critical region from beam-column joint face. (2) Ductility index($\mu$f) were increased with increasing of shear confinement ratio and flexural strength ratio. (3)The specimens with 2ft extension distance showed more ductility than the specimens with 1ft extension distance.

  • PDF

고장력 철근을 사용한 RC 보의 휨연성 평가 (Assessment of Flexural Ductility in RC Beams with High-Strength Reinforcement)

  • 권순범;윤영수;이만섭;임철현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.897-902
    • /
    • 2001
  • Recently, structure performance is maximized by using high strength concrete. In design of structure, concrete need combination with reinforcement, but use of common strength reinforcement make member complex bar placement, so high strength concrete members require increased strength reinforcement. If common strength reinforcement replaced by equal tension area of high strength reinforcement, reinforcement ratio increase and brittle failure of member may occur by material change. So, adequate upper limit of strength ratio is required to affirm ductile behavior in application of high strength reinforcement. In this study, ductility behavior was analysed by factor of reinforcement ratio, strength of concrete and reinforcement. The result indicate that ductile failure is shown under 0.35 $\rho_{b}$ in any reinforcement strength of same section and high strength concrete of 800kg/$cm^{2}$ used commonly is compatible with reinforcement of 5500kg/$cm^{2}$.

  • PDF

접착공법에 의해 전단보강된 RC보의 전단강도 예측 (Shear Strength Prediction of RC Beams Strengthened by Externally Bonding Method)

  • 박성민;변근주;송하원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2001
  • Steel plate or fiber composite plate are mainly used in externally bonding method. Shear strengthening by externally bonding method is to confirm shear safety and to avoid brittle failure. In case of strengthening by externally bonding method, a failure of structure occurs frequently due to delamination between strengthening plate and concrete. Therefore, it is important to consider the delamination in the strengthening design. The objective of this study is to propose a modified shear strength evaluation by considering the delamination. The delamination criteria of strengthening plate is established by the ultimate strain and shear stress. And shear strength of RC beams is proposed in terms of the delamination criteria. The proposed shear strength is compared with test results and verified through the comparison.

  • PDF

플랫 플레이트-기둥 접합부의 내진성능에 대한 해석연구 (Numerical Study on Seismic Resistance of Flat Plate-Column Connections)

  • 박홍근;최경규;황영현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.891-896
    • /
    • 2002
  • Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column connection. In the present study, numerical studies were performed for interior connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, shear, torsional moment around the connection were investigated. Based on the findings of the numerical studies, the disadvantages of current design methods were discussed.

  • PDF

세그멘탈 합성보의 휨 실험 (Flexural Tests on Post-Tensioned Segmental Composite Beam)

  • 김인규;설동재;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.487-492
    • /
    • 2002
  • The interior portion of Gerber's beam are constructed with post-tensioned segmental composite beams in this study. A precast concrete member which is larger than the limits of domestic transportation regulation in weight, length, and volume is divided into three parts, transported separately, and erected with a composite member by post-tensioning in site. Static flexural loading tests are performed on Gerber's type frames which are consisted with 2.5m overhangs and 5m interior beams composited from three pieces. The connection of overhang to interior composite beam and beam to beam, and flexural performance of interior portion of Gerber's beam are examined thoroughly. All of the tests are ended with a compression failure of the interior composite beams over the design strength of homogeneous beams. The brittle connection failures or tensile failures with the failure of lower strand was not observed in any test frames.

  • PDF