• Title/Summary/Keyword: brightness threshold

Search Result 116, Processing Time 0.02 seconds

Contrast Image Enhancement Using Multi-Histogram Equalization

  • Phanthuna, Nattapong;cheevasuwit, Fusak
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.161-170
    • /
    • 2015
  • Mean separated histogram equalization in order to preserve the original mean brightness has been proposed. To provide the minimum mean brightness error after the histogram modification, the input image's histogram is successively divided by the factor of 2 until the mean brightness error is satisfied the defined threshold. Then each divided group or sub-histogram will be independently equalized based on the proportional input mean. To provide the overall minimum mean brightness error, each group will be controlled by adding some certain pixels from the adjacent grey level of the next group for giving its mean near by the corresponding the divided mean. However, it still exists some little error which will be put into the next adjacent group. By successive dividing the original histogram, we found that the absolute mean brightness error is gradually decreased when the number of group is increased. Therefore, the error threshold is assigned in order to automatically dividing the original histogram for obtaining the desired absolute mean brightness error (AMBE). This process will be applied to the color image by treating each color independently.

THE MODIFIED BRIGHTNESS TEMPERATURE DIFFERENCE FOR AEROSOL DETECTION

  • Kim, Jae-Hwan;Ha, Jong-Sung;Lee, Hyun-Jin
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.794-796
    • /
    • 2006
  • This study investigated the Brightness Temperature Difference threshold as criterion between aerosols and clouds in conjunction with radiative transfer model. Surface temperature is caused by a significant error over 50% in the BTD threshold. In addition, The BTD threshold contains the uncertainties about 20% due to the surface emissivity and 8% due to the satellite zenith angle. Therefore, we have composed the Look-up table for BTD between 11㎛and 12㎛ according to satellite zenith angle, surface temperature, and surface emissivity. The modified BTD show the enhanced signal, especially over bright surface such as desert in China. However, a weak aerosol signal over Ocean remains in the modified BTD.

  • PDF

Development of Cloud Detection Algorithm for Extracting the Cloud-free Land Surface from Daytime NOAA/AVHRR Data (NOAA/AVHRR 주간 자료로부터 지면 자료 추출을 위한 구름 탐지 알고리즘 개발)

  • 서명석;이동규
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.3
    • /
    • pp.239-251
    • /
    • 1999
  • The elimination process of cloud-contaminated pixels is one of important steps before obtaining the accurate parameters of land and ocean surface from AVHRR imagery. We developed a 6step threshold method to detect the cloud-contaminated pixels from NOAA-14/AVHRR datime imagery over land using different combination of channels. This algorithm has two phases : the first is to make a cloud-free characteristic data of land surface using compositing techniques from channel 1 and 5 imagery and a dynamic threshold of brightness temperature, and the second is to identify the each pixel as a cloud-free or cloudy one through 4-step threshold tests. The merits of this method are its simplicity in input data and automation in determining threshold values. The threshold of infrared data is calculated through the combination of brightness temperature of land surface obtained from AVHRR imagery, spatial variance of them and temporal variance of observed land surface temperature. The method detected the could-comtaminated pixels successfully embedded inthe NOAA-14/AVHRR daytime imagery for the August 1 to November 30, 1996 and March 1 to July 30, 1997. This method was evaluated through the comparison with ground-based cloud observations and with the enhanced visible and infrared imagery.

Brightness Function on TV Viewing Condition (TV 시청 조건에서의 Brightness Function)

  • 최성호;김희철;장수욱;김은수;한찬호;송규익
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2403-2406
    • /
    • 2003
  • When viewing images, the relative luminance of the surround has a profound impact on the apparent contrast of the image. The dark surround causes the image elements to appear lighter than those viewed in an illuminated surround. For this reason, it is worthwhile to briefly review the general results of brightness sealing under a various viewing condition. Two of the most often cited parers on the topic of brightness scaling are Stevens-stevens and Bartleson-Breneman's function. There are, however, significant differences between the perceptual functions for simple-field and complex-field viewing. In this paper, we research the relationship between Steven's power law and Bartleson-Breneman's function. We present an appropriate brightness perception function due to TV system viewing conditions. Highlight luminance peak and absolute brightness threshold value in various adaptation levels are obtained from the proposed brightness function . Also, the luminance value of black level to produce the same contrast ratio with variety of display highlight luminance peak is obtained from the proposed brightness function.

  • PDF

A Moving Target Tracking Algorithm Using Integral Projection (가산 투엽법을 이용한 이동 물체 추적 방법)

  • 김태원;서일홍;양해원;오상록;임달호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.7
    • /
    • pp.569-581
    • /
    • 1989
  • This paper deals with a tracking algorithm based on integral projection which tracks moving targets with varying brightness and size. An adaptive windowing technique is employed to reduce the sensitivity of the system to the complex background image and also to reduce the computational load. The threshold value is determined by considering both the size and the threshold value of the brightness intensity of the recognized target obtained in the previous processing step. Window position is estimated by using the information of the velocity and acceleration of the target. And integral projection is applied to find the position of the target in the window accurately. Experimental results show that moving targets with varying brightness and size can be tracked properly in noisy environments.

  • PDF

A Study on Preprocessing Technique for Fingerprint Recognition using Applied Slit-Sum Method (Slit-Sum 방법을 응용한 지문인식 전처리 기술 연구)

  • 임철수;조성원
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.4
    • /
    • pp.46-50
    • /
    • 2002
  • This paper suggests the adaptive binary method which applies advanced silt sum technique, so that threshold value can be changed heuristically according to the brightness of captured fingerprint image. Through this research, we tried to resolve threshold value setting issue by the local differences of brightness of fingerprint image in the binary image preprocessing. The experimental results show that our proposed preprocessing method demonstrates the better recognition accuracy and can be applied to minutiae extraction algorithm for fingerprint recognition system.

  • PDF

The Improvement of Infrared Brightness Temperature Difference Method for Detecting Yellow Sand Dust

  • Ha, Jong-Sung;Kim, Jae-Hwan
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.149-152
    • /
    • 2007
  • The detection of yellow sand dust using satellite has been utilized from various bands from ultraviolet to infrared channels. Among them, Infrared channels have an advantage of detecting aerosols over high reflecting surface as well as during nighttime. Especially, brightness temperature difference between 11 and 12{\mu}m(BTD) was often used to distinguish between water cloud and yellow sand, because Ice and liquid water particles preferentially absorb longer wavelengths while aerosol particles preferentially absorb shorter wavelengths. We have found that the BTD significantly depends on surface temperature, emissivity, and zenith angle and thereby the threshold of BTD. In order to overcome these problems, we have constructed the background brightness temperature threshold of BTD and then subtracted it from BTD. Along with this, we utilized high temporal coverage of geostationary satellite, MTSAT-1R, to verify the reliability of the retrieved signal in conjunction with forecasted wind information. The statistical score test illustrated that this newly developed algorithm showed a promising result for detecting mineral dust by reducing the errors in the current BTD method.

  • PDF

Determination of Optimum Threshold for Accuracy of People-counting System Based on Motion Detection

  • Ryu, Hanseul;Song, Junho;Lee, Boram;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.299-304
    • /
    • 2015
  • Objectives: A people-counting system measures real-time occupancy through motion detection. Accurate people-counting can be used to calculate suitable ventilation demands. This study determined the optimum motion threshold for a people-counting system. Methods: In a closed room with two occupants moving constantly, different thresholds were tested for the accuracy of a people-counting system. The experiments were conducted at 150, 300, 450 and 600 lux. These levels of brightness included the illumination levels of most public indoor areas. The experiments were repeated with three types of clothing coloration. Results: Overall, a threshold of 16 provided the lowest mean error percentage for the people-counting system. Brightness and clothing color did not have a significant impact on the results. Conclusion: A people-counting system could be used with threshold of 16 for most indoor environments.

A Study on How to Minimize the Luminance Deviation of AC-LED Lighting (교류 LED 조명의 빛 밝기 편차를 최소화하는 방법에 대한 연구)

  • Dong Won Lee;Bong Hee Lee;Byungcheul Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.255-260
    • /
    • 2023
  • In order to spread LED lighting, LED lighting technology directly driven by alternating current (AC) commercial power has recently been introduced. Since current does not flow at a voltage lower than the threshold voltage of the LED, a non-conductive section occurs in the current waveform, and the higher the threshold voltage of the LED, the more discontinuous current waveforms are generated. In this paper, multi-LED modules are connected in series so that the threshold voltage can be adjusted according to the number of LED modules. A small number of LED modules are driven at a low instantaneous rectified voltage, and a large number of LED modules are driven at a high instantaneous rectified voltage to lengthen the overall lighting time of AC-LED lighting, thereby minimizing the luminance deviation of AC-LED lighting. In addition, the load current flowing through the LED module is adjusted to be the same as the design current even at the maximum rectified voltage higher than the design voltage, so that the light brightness of the LED module is kept constant. Therefore, even if the rectified voltage applied to the LED module changes, the AC-LED lighting in which the light brightness is constant and the luminance deviation is minimal has been realized.

Fabrication and Characteristics of Electroluminescent Lamp (전계발광램프의 제작 및 특성)

  • 박욱동;최규만;최병진;김기완
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.5
    • /
    • pp.101-105
    • /
    • 1994
  • The EL lamp have been fabricated by screen printing method. the thickness of BaTiO$_3$ dielectric layer and ZnS:Cu phosphor layer was 20 $\mu$m and 40 $\mu$m, respectively. The threshold voltage of green El lamp was 50 $V_{p-p}$ and the maximum brightness was 13.5 $\mu$ W/cm$^2$ at frequency of 700 Hz and the input voltage of 250 $V_{p-p}$. Also when the Rodamin G6 of 0.02 g was doped, the threshold voltage of white EL lamp was 70 $V_{p-p}$ and the maximum brightness was 34 $\mu$W/cm$^2$.

  • PDF