• 제목/요약/키워드: brightness

검색결과 2,950건 처리시간 0.032초

전사성 다구찌 동특성을 활용한 LCD Crosstalk 개선 (LCD Crosstalk Improvement Based on Transformability Taguchi Dynamic Characteristics)

  • 지수윤;장중순
    • 산업경영시스템학회지
    • /
    • 제37권4호
    • /
    • pp.259-268
    • /
    • 2014
  • Uniform brightness is very crucial for LCD panels, which should be made in during manufacturing. Usually some compensating algorithms are applied to recover the brightness deviation that occurs in actual panels. Although such remedying tools are used, it is very hard to prevent horizontal or vertical crosstalks that represent the brightness level difference in horizontal or vertical direction. This research applied transformability Taguchi dynamic characteristics and "nominal is best" static characteristic simultaneously to design the compensating circuit optimally that may reduce the crosstalks and make uniform brightness level.

밝기 보존을 위한 동적 영역 분할을 이용한 적응형 명암비 향상기법 (An Adaptive Contrast Enhancement Method using Dynamic Range Segmentation for Brightness Preservation)

  • 박규희;조화현;이승준;윤종호;최명렬
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.14-21
    • /
    • 2008
  • In this paper, we propose an adaptive contrast enhancement method using dynamic range segmentation. Histogram Equalization (HE) method is widely used for contrast enhancement. However, histogram equalization method is not suitable for commercial display because it may cause undesirable artifacts due to the significant change in brightness. The proposed algorithm segments the dynamic range of the histogram and redistributes the pixel intensities by the segment area ratio. The proposed method may cause over compressed effect when intensity distribution of an original image is concentrated in specific narrow region. In order to overcome this problem, we introduce an adaptive scale factor. The experimental results show that the proposed algorithm suppresses the significant change in brightness and provides wide histogram distribution compared with histogram equalization.

The Study of High Brightness Prism Patterned LGP using Optical Simulation Analysis

  • Ok, Chul-Ho;Han, Jeong-Min;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권4호
    • /
    • pp.178-181
    • /
    • 2007
  • We have designed high performance prism light-guide plate (LGP) in 17 inch TFT-LCD. In test result to embody high brightness BLU in case of LGP of base and upper surface with 17 inch, thickness 8 mm adding prism construct, it is superior brightness improvement than previous that of printing form about some 20% and in this course to embody actual material it succeeded prism LGP production by 17 inch injection form process.

마이크로 사이즈 인출구경을 이용한 고휘도 이온빔 인출 시스템 개발 (Development of a High Brightness Ion Beam Extraction System using Micro-size Aperture)

  • 김윤재;박동희;정형설;황용석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.19-23
    • /
    • 2005
  • In order to develop a high brightness ion source using plasma, the ion beam extraction system with an aperture of $100{\mu}m$ in diameter has been designed and constructed. It is observed that over 500nA of He ion beam current can be extracted. With such an optimized condition, $\~10^3\;A/cm^2sr$ beam brightness can be measured by emittance scanner, which is believed to be a promising result for developing next generation FIB.

  • PDF

확장된 Fuzzy Clustering 알고리즘을 이용한 자동 목표물 검출 (Automatic Target Detection Using the Extended Fuzzy Clustering)

  • 김수환;강경진;이태원
    • 전자공학회논문지B
    • /
    • 제28B권10호
    • /
    • pp.842-913
    • /
    • 1991
  • The automatic target detection which automatically identifies the location of the target with its input image is one of the significant subjects of image processing field. Then, there are some problems that should be solved to detect the target automatically from the input image. First of all, the ambiguity of the boundary between targets or between a target and background should be solved and the target should be searched adaptively. In other words, the target should be identified by the relative brightness to the background, not by the absolute brightness. In this paper, to solve these problems, a new algorithm which can identify the target automatically is proposed. This algorithm uses the set of fuzzy for solving the ambiguity between the boundaries, and using the weight according to the brightness of data in the input image, the target is identified adaptively by the relative brightness to the background. Applying this algorithm to real images, it is experimentally proved that it is can be effectively applied to the automatic target detection.

  • PDF

TEMPORAL AND SPATIAL VARIATIONS OF THE ATMOSPHERIC DIFFUSE LIGHT

  • Kwon, Suk-Min
    • 천문학회지
    • /
    • 제22권2호
    • /
    • pp.141-160
    • /
    • 1989
  • In order to derive time dependence of the atmospheric diffuse light, which consists of the airglow continuum emission and diffusely scattered radiations of the intergrated starlight, the diffuse Galactic light, and the zodiacal light, we have analyzed the meridian scan observations of the sky brightness at $5,080\;{\AA}$ and $5,300\;{\AA}$. Amplitude of the time-variation becomes larger for lower elevation, and maximum amplitude is found to be about $50\;S_{10}(V)_{G2V}$ at elevation $10^{\circ}$. The atmospheric diffuse radiation attains maximum brightness at around midnight, and afterward it decreases slowly with time. The time-variations for the two wavelengths are similar to each other. The observed brightness distribution of the diffuse light along the zenith distance is fitted to an empirical relation of two parameters. By making the two parameters time-dependent, we describe the spatial and time variations of the atmospheric diffuse light. This enables us to make time dependent correction for the atmospheric diffuse component in the reduction of zodiacal light brightness.

  • PDF

Bleaching of Kraft Bagasse Pulp in Presence of Polyoxometalate Catalyst

  • Ibrahim A. A.;El-Sakhawy Mohamed;Kamel Samir
    • 펄프종이기술
    • /
    • 제37권5호통권113호
    • /
    • pp.56-62
    • /
    • 2005
  • The catalytic effect of molybdovandophosphate heteropolyanion (HPAs) on the delignification of kraft bagasse pulp by hydrogen peroxide has been investigated. Very small amounts of the catalyst (0.05 0.3 mM/l) gave convenient results. Partial reduction of the catalyst was also studied. The effect of reaction medium (water, ethyl alcohol and acetone) on the bleaching was also studied. The results obtained show that the optimum condition for bleaching in presence of polyoxometalate were 0.05 mM/l catalyst concentration at $70^{\circ}C$ reaction temperature and $7\%$ consistency at pH 2 in aqueous medium. The ratio of water to solvent of 60:40 from acetone gives higher brightness than ethyl alcohol. The catalyst solution can be reused for 5 times without any reduction in brightness. ESR for the blank and exhausted solutions under different conditions was also carried out to find the relation between reduced metals and pulp brightness.

Desktop-LED lighting for Eye Muscle Movement by Adjusting the Light Illuminance and Color Temperature

  • Kim, Byoung-Chul;Kim, Seon-Jong;Kim, Joo-Man
    • International journal of advanced smart convergence
    • /
    • 제9권4호
    • /
    • pp.203-208
    • /
    • 2020
  • In this paper, we propose the design and implementation of a desktop LED stand and smart app that automatically adjusts color temperature and illuminance for optimal brightness and eye health by improving the structural problem of the LED stand. It is a tabletop LED stand that supports optimal brightness through color temperature control and heat transfer through infrared LED to relieve eye strain through blood circulation and muscle movement. The LED stand works with the smartphone to automatically adjust the optimal brightness and color temperature for the user's environment. In addition, the brightness of the infrared LED is adjusted to a living frequency of 4Hz to relax the eye muscles and reduce eye strain. This study implemented an effective measured data-based system of previous studies through the color temperature and illumination of LED lighting, and near-infrared rays, and presented meaningful results by conducting an experiment to prove the effect through subjects.

고휘도 LED를 이용한 머신비전용 조명광원 제어기 개발 (Using High Brightness LED Light Source Controller for Machine Vision)

  • 박양재
    • 디지털융복합연구
    • /
    • 제12권4호
    • /
    • pp.311-318
    • /
    • 2014
  • 본 논문은 의료영상시스템, 공장자동화 시스템에서 핵심기술인 정확한 검사와 계측을 위하여 보다 선명하고 안정정인 환경을 제공하기 위한 조명으로 고휘도 LED를 이용한 조명광원의 제어기를 개발하였다. 고휘도 LED 전용드라이버를 장착하여 정전류 방식으로 안정된 전원을 공급하도록 설계하고, 32비트 ARM 프로세서 코어를 사용하여 화상처리 시 필수적인 요소인 광량을 256단계로 나누어 리모트 컨트롤 및 외부 인터페이스가 가능하도록 하여 볼륨의 저항 값 오차로 인하여 발생되는 밝기 값의 부정확을 방지하고 디지털화함으로써 빛의 재현성을 개선하였다. 아나로그 전원에 비하여 조광 범위가 넓고 낮은 레벨에서도 조광이 가능하도록 설계 하였으며 또한 RS-485 통신기능을 추가하여 외부장치로부터 데이터를 받아 사용자가 광량조절 및 ON/OFF 제어가 가능하도록 개발 하였다.

구내방사선사진의 프랙탈 분석을 이용한 골다공증 예측 (Prediction of osteoporosis using fractal analysis on periapical radiographs)

  • 박금미;정연화;나경수
    • Imaging Science in Dentistry
    • /
    • 제35권1호
    • /
    • pp.41-46
    • /
    • 2005
  • Purpose : The purpose of this study was to investigate whether the fractal dimension and radiographic image brightness of periapical radiograph were useful in predicting osteoporosis. Materials and Methods : Ninety-two postmenopausal women were classified as normal, osteopenia and osteoporosis group according to the bone mineral density of lumbar vertebrae and periapical radiographs of both mandibular molar areas were taken. The ROIs of 358 areas were selected at periapical and interdental areas and fractal dimension and radiographic image brightness were measured. Results : The fractal dimension in normal group was significantly higher than that in osteoporosis group at periapical ROI (P < 0.05). The radiographic image brightness in normal group was higher than that in osteopenia and osteoporosis group. There was significant difference not only between normal and osteopenia group (P < 0.05) but also within osteopenia and osteoporosis group (P< 0.01) at periapical ROI. Significant difference was observed not only between normal and osteopenia group but also between normal and osteoporosis group at interdental ROI (P< 0.01). Positive linear relationship was weakly shown at Pearson correlation analysis between fractal dimension and radiographic image brightness. BMD significantly correlated with fractal dimension at periapical ROI (P< 0.01), and BMD and radiographic image brightness significantly correlated at both periapical and interdental ROIs (P< 0.01). Conclusion : This study suggests that the fractal dimension and radiographic image brightness of periapical ROI may predict BMD. (Korean J Oral Maxillofac Radiol 2005: 35 : 41-6)

  • PDF