• 제목/요약/키워드: bridge slab

검색결과 419건 처리시간 0.023초

강상형교 설계최적화를 위한 마이크로 유전알고리즘의 적용 (An Application of Micro-GA for the Design Optimization of Steel Box Girder Bridges)

  • 김제헌;류연선;김정태;조현만
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.154-161
    • /
    • 2001
  • A procedure of the design optimization for steel box girder bridges using micro genetic algorithms(μGA) is developed. The effect of population size is investigated and the efficiency and reliability of μGA is demonstrated in the optimum design of steel box girder bridges. Optimum design problems of steel box girder bridges are formulated, where tile design of concrete slab is based on the USD specifications and steel box girder based on LRFD respectively. Design of optimizations of single-span and 2-span steel box girder bridges are performed with the population size of 5, 40, 80, and 120, respectively The μGA-based optimum design of the 3-span steel box girder bridge is compared with SQP results.

  • PDF

잔교식 안벽 해석시 수평지반반력계수의 적용 (Application of the Lateral Subgrade Reaction Modulus in Landing Pier)

  • 박시범;김지용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1707-1711
    • /
    • 2008
  • Landing pier is connect from onshore to offshore with bridge type that a coast structure. The sub-structure is consisted of vertical or batter pile and combined reinforced concrete slab. These days useful design method of quay wall of landing pier type for pile foundation analysis abide by approximate depth of pile supported method, "Harbor and port design criterion, 2005 The ministry of land transport and maritime affairs". The approximate depth of pile supported is calculated two kind of method that one is assume to below depth of 1/$\beta$ from assumed submarine surface and other is 1st fixpoint depth by Chang(1937)'s theory. By this paper, FEM dynamic analysis of 3-dimensions was achieved that it has compared pile fixed end modeling with elastic spring modeling base on winkler theory.

  • PDF

외기조건이 개질된 라텍스 혼입콘크리트 슬래브 표면에 미치는 영향 (Effects of climate condition on concrete slab with modified-latex)

  • 차훈;김대건;최상환;문경식
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.7-8
    • /
    • 2014
  • Latex-modified concrete using ready mix concrete (R-LMC) was developed for application of building construction project (specifically, the rooftop of a parking garage unable to use heavy equipments for bridge deck overlay) due to three major outstanding properties of R-LMC; bond strength, resistance of cracks at early age, and resistance of freezing and thawing. However, R-LMC at the placement stage is required to be sufficiently cured because R-LMC is very sensitive to rate of evaporation of surface moisture. This study focused on effects of different curing methods and climate condition on cracks on the surface of hardened R-LMC considering the chart of rate of evaporation of surface moisture from concrete provided by American Concrete Institute in manual for placement of latex modified concrete.

  • PDF

체결장치의 수직 방향에 대한 실험적 연구 (An Experimental Study of Fastening System for Vertical Directions)

  • 김정훈;한상윤;임남형;강영종
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1312-1319
    • /
    • 2006
  • Several countries including Korea, Japan and European countries have reached the stage of planning, constructing their high-speed railway systems. High-speed train will become a key tool for intercity passenger transportation. Before that, safety of high-speed train must be secured. It is connected directly with track. The track is composed of ballast, tie, fastening and rail. Also, the fastening system makes tie and rail connect. In this case of the railway bridges used concrete slab track, the deflection of the bridge cause uplife of the rail at the areas between segments. In the structural analysis about it, stiffness of the fastening systems has been assumed. Therefore, use of the stiffness according to an experimental study needs. In this study, the stiffness values of various types of fastening systems are determined by the experiment and the structural behavior of fastening system is analyzed.

  • PDF

충격공진을 이용한 콘크리트 상태 평가를 위한 주성분 분석의 적용 (Application of the Principal Component Analysis to Evaluate Concrete Condition Using Impact Resonance Test)

  • 윤영근;오태근
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.95-102
    • /
    • 2019
  • Non-destructive methods such as rebound hardness method and ultrasonic method are widely studied for evaluating the physical properties, condition and damage of concrete, but are not suitable for detecting delamination and cracks near the surface due to various constraints of the site as well as the accuracy. Therefore, in this study, the impact resonance method was applied to detect the separation cracks occurring near the surface of the concrete slab and bridge deck. As a next step, the principal component analysis were performed by extracting various features using the FFT data. As a result of principal component analysis, it was analyzed that the reliability was high in distinguishing defects in concrete. This feature extraction and application of principal component analysis can be used as basic data for future use of machine learning technique for the better accuracy.

Finite element response sensitivity analysis of continuous steel-concrete composite girders

  • Zona, Alessandro;Barbato, Michele;Conte, Joel P.
    • Steel and Composite Structures
    • /
    • 제6권3호
    • /
    • pp.183-202
    • /
    • 2006
  • The behavior of steel-concrete composite beams is strongly influenced by the type of shear connection between the steel beam and the concrete slab. For accurate analytical predictions, the structural model must account for the interlayer slip between these two components. This paper focuses on a procedure for response sensitivity analysis using state-of-the-art finite elements for composite beams with deformable shear connection. Monotonic and cyclic loading cases are considered. Realistic cyclic uniaxial constitutive laws are adopted for the steel and concrete materials as well as for the shear connection. The finite element response sensitivity analysis is performed according to the Direct Differentiation Method (DDM); its analytical derivation and computer implementation are validated through Forward Finite Difference (FFD) analysis. Sensitivity analysis results are used to gain insight into the effect and relative importance of the various material parameters in regards to the nonlinear monotonic and cyclic response of continuous composite beams, which are commonly used in bridge construction.

고속전철 PSC 박스거더 교량의 횡방향 해석 (Transverse Analysis of Prestressed Concrete Box Girder High-Speed Railway Bridges)

  • 김병석;김영진;박성용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.47-53
    • /
    • 1998
  • Many kinds of methods have been developed to carry out transverse analysis of prestressed concrete(PSC) box girder bridges. However, most bridge engineers only use the simple frame model to analyze PSC box girder in transverse direction because of its simplicity and easy usage. But, this frame model has many problems such that it can't consider warping, distortion and longitudinal load distribution. In this study, the results from simple frame model and 3-dimensional shell model with UIC load are compared to show its validity. The results from frame model are slightly larger than those of shell model in symmetric loading case. But, positive bending moment of top slab is larger in shell model than frame model in case subject to anti-symmetric loading. It shows that simple frame model can't always give conservative results, so a practical tool whose treatment is easy and whose product is reliable shall be developed as soon as possible.

  • PDF

Required ties in continuous RC beams to resist progressive collapse by catenary action

  • Alrudaini, Thaer M.S.
    • Structural Engineering and Mechanics
    • /
    • 제78권4호
    • /
    • pp.403-411
    • /
    • 2021
  • Ties are mandated by many design guidelines and codes to prevent the progressive collapse of buildings initiated by local failures. This study develops a model to estimate catenary/cable action capacity and the required ties in continuous reinforced concrete beams to bridge above the potential failed interior columns. The developed model is derived based on virtual work method and verified using test results presented in the literature. Also, parametric investigations are conducted to estimate the required ties in continuous reinforced concrete beams supporting one-way slab systems. A comparison is conducted between the estimated tie reinforcement using the developed model and that provided by satisfying the integrity provisions of the ACI 318-14 (2014) code. It is shown that the required tie reinforcements to prevent progressive collapse using the developed model are obviously larger than that provided by the integrity requirements of the ACI 318-14 (2014) code. It has been demonstrated that the increases in the demanded tie reinforcements over that provided by satisfying ACI 318-14 (2014) integrity provisions are varied between 1.01 and 1.46.

교량 내하력 평가를 위한 정적재하시험 및 동적재하시험 특성 (Characteristics of Static Loading and Dynamic Loading Tests for Bridge Capability)

  • 이상훈
    • 한국재난정보학회 논문집
    • /
    • 제16권4호
    • /
    • pp.638-649
    • /
    • 2020
  • 연구목적: 본 연구에서는 공용년수 20년이 경과된 콘크리트 단순 슬래브교를 대상으로 하여 대상교량 구조물의 내하성능을 평가하는 것을 목적으로 하였다. 연구방법: 정적재하시험 및 동적재해시험을 수행함으로써 변위, 변형율, 충격계수, 고유진동수 값을 실측하였으며, 해석방법을 통해 평가하였다. 연구결과: 본 연구를 통해 나타난 주요 결과는 다음과 같다. 첫째, S1 최대 변위 및 최대 변형률은 각각 2.917 mm, 44.720 𝜇ε(인장), -13.760 𝜇ε(압축)로 평가되었으며, S2 최대 변위 및 최대 변형률은 각각 2.100 mm, 4.870 𝜇ε(인장)로 나타났다. 둘째, 최대 실측충격계수는 S1 A-A단면에서 0.242로 나타났으며, 최대 실측충격계수는 S2 C-C단면에서 0.198로 나타났다. 셋째, 고유진동수를 해석결과, 6.086Hz로 평가되었고, 측정결과 6.152Hz-6.738Hz의 범위로 나타났다. 결론: 시험대상 교량은 설계하중에 대하여 양호한 거동 및 특성을 보이는 것으로 평가할 수 있다.

Mapped relationships between pier settlement and rail deformation of bridges with CRTS III SBT

  • Jiang, Lizhong;Liu, Lili;Zhou, Wangbao;Liu, Xiang;Liu, Chao;Xiang, Ping
    • Steel and Composite Structures
    • /
    • 제36권4호
    • /
    • pp.481-492
    • /
    • 2020
  • To study the rail mapped deformation caused by the pier settlement of simply - supported bridges with China Railway Track System III (CRTS III) slab ballastless track (SBT) system under the mode of non-longitudinal connection ballastless track slab, this study derived an analytical solution to the mapped relationships between pier settlement and rail deformation based on the interlayer interaction mechanism of rail-pier and principle of stationary potential energy. The analytical calculation results were compared with the numerical results obtained by ANSYS finite element calculation, thus verifying the accuracy of analytical method. A parameter analysis was conducted on the key factors in rail mapped deformation such as pier settlement, fastener stiffness, and self-compacting concrete (SCC) stiffness of filling layer. The results indicate that rail deformation is approximately proportional to pier settlement. The smaller the fastener stiffness, the smoother the rail deformation curve and the longer the rail deformation area is. With the increase in the stiffness of SCC filling layer, the maximum positive deformation of rail gradually decreases, and the maximum negative deformation gradually increases. The deformation of rail caused by the pier settlement of common-span bridge structures will generate low-frequency excitation on high-speed trains.