• Title/Summary/Keyword: breathing measurement

Search Result 146, Processing Time 0.027 seconds

Dosimetric Analysis on the Effect of Target Motion in the Delivery of Conventional IMRT, RapidArc and Tomotherapy

  • Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.164-170
    • /
    • 2017
  • One of the methods to consider the effect of respiratory motion of a tumor target in radiotherapy is to establish a treatment plan with the internal target volume (ITV) created based on an accurate analysis of the target motion displacement. When this method is applied to intensity modulated radiotherapy (IMRT), it is expected to yield a different treatment dose distribution under the motion condition according to the IMRT method. In this study, we prepared ITV-based IMRT plans with conventional IMRT using fixed gantry angle beams, RapidArc using volumetric modulated arc therapy, and tomotherapy using helical therapy. Then, the variation in dose distribution caused by the target motion was analyzed by the dose measurement in the actual motion condition. A delivery quality assurance plan was prepared for the established IMRT plan and the dose distribution in the actual motion condition was measured and analyzed using a two-dimensional diode detector placed on a moving phantom capable of simulating breathing movements. The dose measurement was performed considering only a uniform target shape and motion in the superior-inferior (SI) direction. In this condition, it was confirmed that the error of the dose distribution due to the target motion is minimum in tomotherapy. This is thought to be due to the characteristic of tomotherapy that treats the target sequentially by dividing it into several slices. When the target shape is uniform and the main target motion direction is SI, it is considered that tomotherapy for the ITV-based IMRT method has a characteristic which can reduce the dose difference compared with the plan dose under the target motion condition.

Algorithm Development of Human Body Bio-Signal Measurement based on Sampling Time using Doppler Radar Information (도플러 레이더 정보를 이용한 샘플링 시점 기반의 생체 신호 측정 알고리즘 개발)

  • Ryu, Jae-Chun;Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.322-327
    • /
    • 2020
  • Recently, a research on obtaining a vital signal using a Doppler radar has been developed and is used as a technology applied to patients in bed. However, in the case of the measured pulse, the respiration signal is generated as noise, resulting in a problem of lowering accuracy. In this paper, we propose a bio-signal measurement algorithm based on the sampling point to improve the accuracy of the signal for measuring the pulse rate when measuring bio-signals using a Doppler radar. The proposed algorithm improves the accuracy of the measured bio-signal by removing noise generated when measuring biosignals based on two sampling points. Compared with actual medical equipment and existing bio-signal algorithms, it is more than 90% similar to medical equipment. In addition, it was confirmed that severe amplitude change was minimized compared to the existing algorithm.

Effects of Posture Correction Training on Pulmonary Function with Turtle Neck Syndrome (자세교정훈련이 거북목증후군의 폐기능에 미치는 영향)

  • Jang, Cheul
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.183-192
    • /
    • 2021
  • Purpose : The purpose of this study was to investigate the impact of postural correction training on pulmonary function on 28 college students suspected of turtle neck syndrome, and the following conclusions were obtained. Methods : Turtle neck syndrome suspicion 28 person were randomly divided into a posture training group (n = 14) and group that does not perform posture training (n = 14). Respiratory function was measured by SPIROVIT SP-1 and respiratory gas analyzer. The posture training group performed balloon blowing and stair climbing after 20 minutes of posture training, and the group without posture training carried out balloon blowing training and stair climbing. Five times a week and for two weeks. Results : 1. The comparison of the FVC before and after experiments caused by balloon blowing showed a higher level of effortful pulmonary function in the control group than in the experimental group. 2. Comparison of PEFs before and after the experiment by balloon blowing showed that the experimental group's peak flow rate was higher than that of the control group. 3. Comparison of the FIVC before and after experiments with balloon blowing showed that the comparison of the FIVC showed a higher level of effortless intake pulmonary function in the control group than in the experimental group. 4. The comparison of the maximum ventilation volume(VE) before and after the experimental gas measurement showed that the maximum ventilation rate of the experimental group was higher than that of the control group. 5. The comparison of pre-test and post-test heart rate(HR) by breath gas measurement showed that the heart rate of the control group was higher than that of the experimental group. Conclusion : the results of this study showed that postural correction training, balloon blowing training, and stair climbing could have a positive impact on improving pulmonary function. However, the two-week experiment conducted five times a week showed an increase in pulmonary function, but it was difficult to see the effect due to the short study period. Therefore, it is hoped that later studies will be conducted more systematically on the effects of breathing exercises on improving pulmonary function after post-postural correction training for patients with pulmonary function problems.

Airway analysis in unilateral cleft lip and palate patients (편측성 순$\cdot$구개열자의 기도 분석)

  • Son, Woo-Sung;Baek, Jae-Ho
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.591-598
    • /
    • 2000
  • This study was designed to analysis the airway which affects to breathing, speech and facial growth pattern in unilateral cleft lip and palate patients. Upper airway and the position of hyoid bone pattern were analyzed on the lateral cephalometric radiographs of the 78 subjects of complete unilateral cleft lip and palate group and each group was divided two sub-groups by circumpubertal growth peak and gender. These data were statistically analyzed to examine the difference between pre-circumpubertal growth peak group and post-circumpubertal growth peak one, and between male and female group. The results of this study were as follows: 1. After circumpubertal growth peak stage, the position of hyoid bone was lower than before in both male and female group. 2. After circumpubertal growth peak stage, the measurement were increased in CV3ia-APH, PNS-ad which related to the volume of pharyngeal space. This was due to the decrease of adenoid and anteroiferior growth of mandible and affected to breathing and speech after circumpubertal growth peak. 3. During circumpubertal growth peak stage, all measurements increased more in male than female group, which due to the different amount of growth in different gender. 4. The position of hyoid bone was lower in male than female group in all age group. 5. After circumpubertal growth peak stage, CV3ia-APH increased more in male. This was due to the more growth in madible of male which resulted in the activation of digastric muscle.

  • PDF

Development of Respiratory Motion Reduction Device System (RMRDs) for Radiotherapy in Moving Tumor: Construction of RMRDs and Patient Setup Verification Program

  • Lee, Suk;Chu, Sung-Sil;Lee, Sei-Byung;Jino Bak;Cho, Kwang-Hwan;Kwon, Soo-Il;Jinsil Seong;Lee, Chang-Geol;Suh, Chang-Ok
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.86-89
    • /
    • 2002
  • The purpose is to develop a system to reduce the organ movement from the respiration during the 3DCRT or IMRT. This research reports the experience of utilizing personally developed system for mobile tumors. The patients clinical database was structured for 10 mobile tumors and patient setup error measurement and immobilization device effects were investigated. The RMRD system is composed of the respiratory motion reduction device utilized in prone position and abdominal strip device(ASD) utilized in the supine position, and the analysis program, which enables the analysis on patients setup reproducibility. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the normal tissue volume, field margins and dose volume histogram(DVH) using fluoroscopy and CT images. And, reproducibility of patients setup verify by utilization of digital images. When patients breathed freely, average movement of diaphragm was 1.2 cm in prone position in contrast to 1.6 cm in supine position. In prone position, difference in diaphragm movement with and without RMRDs was 0.5 cm and 1.2 cm, respectively, showing that PTV margins could be reduced to as much as 0.7 cm. With RMRDs, volume of the irradiated normal tissue (lung, liver) reduced up to 20 % in DVH analysis. Also by obtaining the digital image, reproducibility of patients setup verify by visualization using the real-time image acquisition, leading to practical utilization of our software. Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Physiological Analysis of Walking - Physical Exercise for the Promotion of National Health - (걷기의 생리학적 분석 - 체력 증진을 위한 운동 -)

  • Nam, Kee-Yong;Chang, Shin-Yo;Shin, Dong-Hoon;Sung, Nak-Eung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 1970
  • Studies on the analysis of walking were performed on 33 male subjects. A prescription of physical exercise (walking at a speed of greater than 6 km/hr for more than one hour daily) for the promotion of individual health is presented on the basis of walking analysis. Presumptions were made that adequate physical exercise does promote health and is beneficial for the healthy life and increases the life span. These presumptions were derived from the numerous experimental literatures. The literatures support indirectly the presumptions. The following results were obtained and prescription of physical exercise is presented. 1. Oxygen uptake in a walking on a treadmill at a speed of 4 km/hr was only 3 times of the resting oxygen uptake. This kind of moderate exercise did not stimulate the cardiopulmonary system adequately. Heart rate at a 4 km/hr walking was 101 beats/min in boys of less than 20 years old and 83 beats/min in adults. Oxygen uptake at a 6 km/hr walking exceeded 4 times of the resting oxygen uptake. It was interpreted that walking at 6 km/hr stimulated the cardiopulmonary system for the promotion of health. Heart rate at this speed was greater than 110 beats/min in boys and greater than 100 beats/min in adults. 2. Heart rates in a walking of 10 km/hr were 172 beats/min in boys, and 143 beats/min in adults, respectively. Maximal heart rates were 185 beats/min in boys, 180 in office clerks, and 168 beats/min in construction site laboreres. 3. The correlation between heart rate and oxygen uptake was high, namely, r>0.95. Subsequently heart rate could be used as a measure of degree of intensity of physical exercise instead of the cumbersome oxygen uptake measurement. 4. The prescription of physical exercise for the promotion of health is: Daily walking for more than one hour at a speed of greater than 6 km/hr. Bodily functions in this daily walking are in boys (body weight, 50 kg): heart rates of 110 beats/min; breathing frequency, 28/min; oxygen uptake, greater than 4 times of the resting uptake; pulmonary ventilation, 351/min; stride, 124 strides/min; cumulative number of strides for one hour, 7,440 strides, and energy expenditure of more than 300 kcal. In adults (body weight, 60 kg) the bodily functions are: heart rates of 100 beats/min, breathing frequency, 28/min; oxygen uptake, greater than 4 times of the resting uptake; Pulmonary ventilation, 301/min; stride, 127 strides/min; cumulative number of strides for one hour, 7,670 strides, and energy expenditure of more than 300 kcal.

  • PDF

Analysis of Correlation Coefficient Between Movements of Thoracoabdominal Tumors and External Respiration Using Image Guided Radiotherapy(IGRT) (영상유도 방사선치료장치(IGRT)를 이용한 흉·복부 종양의 움직임과 외부호흡과의 상관관계 분석)

  • Kim, Gha-Jung;Hong, Ju-Youn;Han, Sang-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.362-370
    • /
    • 2014
  • This study measured and analyzed the correlation coefficient between movements of thoracoabdominal tumors and external respiration in a free-breathing state, using cyberknife image guided radiotherapy(IGRT). This study subjects included a total of 30 patients with lung tumors(n=10), liver tumors(n=10) and pancreatic tumor(n=10) who underwent radiotherapy, and the movements of tumors were analyzed using converted log data of the tumor motion tracking system(MTS). In a free-breathing state, In relation to Peason's correlation coefficient between external respiration and lung tumors in the entire treatment process, the correlation coefficient was 0.646(p<0.05) in the cranio-caudal direction, 0.365(p<0.088) in the left and right direction and 0.196(p<0.115) in the antero-posterior direction. The correlation coefficient of liver tumors was 0.841(p<0.000) in the cranio-caudal direction, 0.346 (p<0.179) in the left and right direction and 0.691(p<0.001) in the antero-posterior direction. The correlation coefficient of Pancreatic tumors was 0.683(p<0.000) in the cranio-caudal direction, 0.397(p<0.006) in the left and right direction and 0.268(p<0.127) in the antero-posterior direction. In conclusion, the measurement findings of thoracoabdominal tumor movement using IGRT would be helpful in determining an accurate target volume. Moreover, the analysis of correlation between external respiration and movements of internal tumors would provide important information to correct movements of tumors for diverse radiotherapy techniques.

Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images (PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교)

  • Kim, Youngjae;Park, Hoon-Hee;Lee, Joo-Young;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

A Longitudinal Study of the Growth Changes on Nasopharynx and Adenoid of the Korean with Normal Occlusion (정상 교합자의 비인두와 Adenoid 성장에 관한 누년적 연구)

  • JI, Myung-Ju;Park, Kyung-Duk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.373-387
    • /
    • 1996
  • The purpose of this study was to evaluate the growth pattern of nasopharyx and adenoid and to obtain useful measurements for evaluating the fuction of the nasal breathing. The biennial serial cephalometric radiographs of 33 samples(19 male, 14 female) with normal occlusion from 8.5 years to 18.5 years of age were used in this study. The distances, areas and ratios on nasopharynx and adenoid were measured and analyzed in each age and sex. The results of this study might be summarized as follows ; 1. The mean value and standard deviation of each measurement was obtained in each age and sex. 2. The nasopharyngeal height and the nasopharyngeal depth increased significantly by 14.5 years of age in male and 12.5 years of age in female(p<0,05), 3. The relative nasal airway area showed the minimal value at 8.5 years of age and showed significant increase from 10.5 years to 12.5 years of age in male and from 12.5 years to 14,5 years of age in female(p<0.05). 4. In the correlation analysis between the measurements on the nasal airway and the measurement of relative nasal airway area, the measurements of Ad2-PNS, Ad2-PNS/Ho'-PNS and Upper pharynx appeared singnificant correlation with the measurement of relative nasal airway area(p<0.01).

  • PDF

A Study on the Design and Implementation of a Thermal Imaging Temperature Screening System for Monitoring the Risk of Infectious Diseases in Enclosed Indoor Spaces (밀폐공간 내 감염병 위험도 모니터링을 위한 열화상 온도 스크리닝 시스템 설계 및 구현에 대한 연구)

  • Jae-Young, Jung;You-Jin, Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2023
  • Respiratory infections such as COVID-19 mainly occur within enclosed spaces. The presence or absence of abnormal symptoms of respiratory infectious diseases is judged through initial symptoms such as fever, cough, sneezing and difficulty breathing, and constant monitoring of these early symptoms is required. In this paper, image matching correction was performed for the RGB camera module and the thermal imaging camera module, and the temperature of the thermal imaging camera module for the measurement environment was calibrated using a blackbody. To detection the target recommended by the standard, a deep learning-based object recognition algorithm and the inner canthus recognition model were developed, and the model accuracy was derived by applying a dataset of 100 experimenters. Also, the error according to the measured distance was corrected through the object distance measurement using the Lidar module and the linear regression correction module. To measure the performance of the proposed model, an experimental environment consisting of a motor stage, an infrared thermography temperature screening system and a blackbody was established, and the error accuracy within 0.28℃ was shown as a result of temperature measurement according to a variable distance between 1m and 3.5 m.