Inhaled inorganic dusts, such as coal, can cause inflammation and fibrosis in the lungs, known as pneumoconiosis. Diagnosis of pneumoconiosis depends on morphological changes by radiological findings and functional change by pulmonary function test (PFT). Unfortunately, current diagnostic findings are limited only to lung fibrosis, which is usually irreversibly progressive. Therefore, it is important that research on potential and prospective biomarkers for pneumoconiosis should be conducted prior to initiation of irreversible radiological or functional changes in the lungs. Analytical techniques using exhaled breath condensate (EBC) or exhaled gas are non-invasive methods for detection of various respiratory diseases. The objective of this study is to investigate the relationship between inflammatory biomarkers, such as EBC pH or fractional exhaled nitric oxide ($FE_{NO}$), and pneumoconiosis among 120 retired coal miners (41 controls and 79 pneumoconiosis patients). Levels of EBC pH and FENO did not show a statistically significant difference between the pneumoconiosis patient group and pneumoconiosis patients with small opacity classified by International Labor Organization (ILO) classification. The mean concentration of $FE_{NO}$ in the low percentage $FEV_1$ (< 80%) was lower than that in the high percentage (80% $\leq$) (p = 0.023). The mean concentration of $FE_{NO}$ in current smokers was lower than that in non smokers (never or past smokers) (p = 0.027). Although there was no statistical significance, the levels of $FE_{NO}$ in smokers tended to decrease, compared with non smokers, regardless of pneumoconiosis. In conclusion, there was no significant relationship between the level of EBC pH or $FE_{NO}$ and radiological findings or PFT. The effects between exhaled biomarkers and pneumoconiosis progression, such as decreasing PFT and exacerbation of radiological findings, should be monitored.
Journal of Physiology & Pathology in Korean Medicine
/
v.35
no.6
/
pp.249-254
/
2021
The aim of this study was to raise awareness about smoking and to facilitate the induction of smoking cessation. The participants were 49 patients who showed intention to participate in the test. The participants who had done a questionnaire, were asked to quit smoking for about an hour. After taking the breath deeply, they stopped for 20 seconds and measured breathing slowly. Carbon monoxide in the exhalation was higher when the daily smoking amount was higher and the smoking duration was longer, but not significant. In the case of smoking after meal and smoking in bed in the morning, the carbon monoxide level was significantly higher than that in the case of not smoking. It was significantly associated with skin allergic symptoms. The usual exercise habits, drinking and the respiratory disease were not correlated with carbon monoxide levels.
The Journal of the Convergence on Culture Technology
/
v.6
no.3
/
pp.381-392
/
2020
This study is purposed to check up the natural 12 kinds of herbal extracts suitable for hangover and based on the results of contents of phenolic compounds, ABTS radical scavenging activity, alcohol dehydrogenase (ADH), and acetaldehyde dehydrogenase (ALDH). Selected 8 kinds of herbal extracts are blended according to the efficacy and the pearson's correlation between each content and activity. C. sinensis var. sinensis, P. densiflora Gnarl and P. lobata Ohwi showed excellent ADH activity, P. lobata Ohwi had a strong correlation between the content and efficacy, and C. sinensis var. sinensis, P. densiflora Gnarl had a negative correlation. Through the ADH and ALDH activity test of F.1 to F.7, the F.7 showed the highest synergic effect and selected as an optimal formulation. F.7 intake-group, the breath alcohol concentration was significantly reduced to 58% after 30 minutes and 27% after 120 minutes, compared to right after alcohol consumption. After alcohol consumption, there was a significant improvement effect (p<0.05) in tired and thirst in the intake group compared to the non-intake group.
Journal of the Korean Society of Manufacturing Process Engineers
/
v.18
no.5
/
pp.1-8
/
2019
Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.
The purpose of present study was to evaluate the relationship between the early change of gingival condition and methyl mercaptan concentration during experimental gingivitis. Ten men(23-25 years old) whose gingiva were clinically healthy were selected. The participants have ceased to perform all forms of oral hygiene during 14 days and then did thorough plaque control for 7 days. For each subject, the methyl mercaptan concentration was measured by $B.B.Checker^{(R)}$ (Bad Breath Checker with printer, Tokuyama Soda Co.,LTD., Japan)before experiment and 1,4,7,14,21 days during experiment. Plaque index(Silness & $L\ddot{o}e$), gingival sulcus depth and sulcus bleeding index($M\ddot{u}hlemann$ & Son)score were recorded. The results were as follows. 1. Methyl mercaptan concentration increased continuously from the first day to the 14th day, decreased on the 21th day but it was still higher(P<0.001). 2. Plaque index score and sulcus bleeding index score tended to increase on the 4th day, markedly increased on the 14th day and returned to baseline level on the 21th day. 3. There was parallel relationhsip among methyl mercaptan concentration, plaque index score and sulcus bleeding index score. This result suggests that methyl mercaptan concentration increased with deterioration in gingival health, but decreased during recovery of normal health condition.
Bulletin of the Society of Naval Architects of Korea
/
v.6
no.2
/
pp.5-10
/
1969
A stepped bar with seimi-circular stress relieving groove near the fillet was subjected by axial tension in a polarized light field. On the stress concentration factor, the effect of the ratios of the fillet radius, the distance between two relieving grooves and the groove radius to the breath of the narrower portion of the stepped bar have been investigate. Observing the stress concentration in 48 models with various proportions, the conclusion arrived at were as follow: 1) If the fillet radius of the stepped bar is larger than half breadth of the narrower portion, the reduction of the stress concentrations can not be expected. 2) If the fillet radius is smaller than half breadth of the narrower portion of the stepped bar, the stress concentration can be droped to the reasonable range. 3) When the groove radius is larger than a quarter of the difference between the distance of two relieving grooves and the breadth of the stepped bar and smaller than a half of that, the stress concentration factors can have their possible minimum value. 4) When the sun of the breadth of the narrower portion of the stepped bar and twice of the relieving groove radius is smaller than the distance between two relieving grooves, minimum stress concentration can be obtained.
Kim, Jong-Kyu;Kang, Min-Gu;Kim, Soo-Jin;Song, Se-Wook
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.24
no.3
/
pp.321-329
/
2014
Objectives: This study was performed to produce data on the pulmonary toxicity of neodymium oxide($Nd_2O_3$) by intratracheal instillation. Methods: Two groups of rats were exposed to neodymium oxide by intratracheal instillation with doses of 0.5 mg and 2.0 mg, respectively. At two days, four weeks and 12 weeks after exposure, body weight change, organ weight change and histopathological change were observed. At 12 weeks after exposure, lung function change was measured. Results: The body weight of rats in the high concentration group decreased after 12 weeks by 4-5% compared with the control group. At four weeks and 12 weeks after the administration of neodymium oxide, the absolute weight of the lungs of the high concentration group were significantly increased when compared with the control group(p<0.05). At 12 weeks after the injection of neodymium oxide, breath frequency and respiratory minute volume were increased, but inhalation time and expiratory time were decreased. Bronchiolar epithelial hyperplasia, alveolar type II cell hypertrophy/hyperplasia and foreign body granulomatous inflammation were observed in the high exposure group. Conclusions: Body weight decrease, lung absolute weight and breath frequency increase, and pathological lung change were all observed. We found that pulmonary toxicity of neodymium oxide nanoparticles by intratracheal instillation could be confirmed.
The Transactions of the Korean Institute of Electrical Engineers C
/
v.48
no.9
/
pp.676-680
/
1999
To do breath alcohol measurement, a sensor is necessary that it can detect low alcohol gas concentration of 0.01% at least. In this work, a capacitance-type alcohol gas sensor using porous silicon layer is developed to measure low alcohol gas concentration. The sensor using porous silicon layer has some sensitivity at room temperature by very large effective surface area, but there is still much room for improvement. In this experiment, we measured the capacitance of the sensor under 254 nm UV light on the porous silicon layer, in which alcohol solution was kept in a flask at 25, 35, and $45^{\circ}C$ by a heater. As the result, the improvement of sensitivity by illuminating UV light was observed. The increasing rate of the capacitance was shown to be double more than those measured under UV-off state. It is supposed that UV light activates response of the oriental and interfacial polarizations which have slow relaxation time for AC field.
This study was designed to assess the iron nutritional status and anemia of high school students. 383 female subjects in Ulsan Metropolitan city were evaluated using a questionnaire, and a measurement of hematological indices. The average height and weight of the respondents were 161.24$\pm$4.90 cm and 53.12$\pm$6.37kg, repectively. The average BMI(body mass index) was 20.43$\pm$2.26 which was in the normal ramge. The average hemoglobin(Hb) concentration of the subjects was 13.14$\pm$0.97g/dl, and the average hematocrit(Hct) level was 40.84$\pm$17.40%. Transferrin saturation{TS(%)} was 20.86$\pm$10.32%, and the ferritin by Hct(<36%), 27.2%by TS(<14%),26.6% by ferritin(<12 ng/ml). As for clinical symptoms, the greatest number of respondents reported that they experienced ‘decreased ability to concectrate’. Mean daily intakes of iron were 14.89$\pm$4.48 mg and heme iron intakes were 5.04$\pm$2.13 mg, which was 29.6% of total iron intake. The total iron binding capacity(TIBC) was negatively correlated with Hb concentration(r= -0.222, p<0.01). Serum ferritin was positively correlated with Hb concentration(r= - 0.323, p<0.05) and negatively correlated with TIBC(r= -0.367, p<0.01). TS(%) was positively correlated with Hb concentration(r= 0.402, p<0.01) and positively correlated with serum ferritin(r=0.413, p<0.01). As for the correlation between blood biochemistry and clinical symptoms related to anemia, the Hb concentration was negatively correlated with ‘shortening of breath when going upstairs(p>0.05)’ and ‘cold hands and feet’ significantly(r= -0.109, p<0.05). The level of Mean corpuscular volume(MCV) was negatively correlated with ‘feel dizzy when standing up’,‘tired out easily’, and ‘decrease ability to concentrate’ significantly(p<0.05). In particular, the level of Fe was negatively correlated with ‘shortening of breath when going upstairs’ and ‘feeling blue’ significantly(p<0.01). These results suggest That the prevalence of iron deficiency of female high school students is very high, therefore guidelines for diet supports and nutrition education to improve their iron status should be provided.
Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.