• 제목/요약/키워드: breath

검색결과 738건 처리시간 0.028초

Human Voice, This Mystery

  • Horiuchi, Terumichi
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 1996년도 10월 학술대회지
    • /
    • pp.378-378
    • /
    • 1996
  • Human beings and chimpanzees are very much alike. and scientists say there is only 1% difference between them. Contrary to our expectations, the difference lies not in brains but in tracheas ( windpipes ). Those of human beings are bigger and longer than those of chimpanzees. Thu means more air is inspired and expired as breath. About breath there are interesting descriptions in the Bible. In the Genesis it says God made a man out of soil and breathed life-giving breath into his nostrils and the man began to live. In other part it says life exists between incoming breath and outgoing breath. Thus breath plays key role is our life. In Hebrew and Greek, breath and spirit are the same words. In Hebrew it is ‘Luahf’ and in Greek, ‘Pneuma’ With breath and mouth organs human beings produced voice, and with haritage and through leaning we train our voice to reach the level of language which convey our culture. My contention is to realize the gift of voice and train it so that it can perform proper function as a tool of conveying our thought and culture. This is a kind of practice of speech and it may be called speechology. It includes the following practical methods: 1. Try to read aloud. 2. Encourage recitation, 3. Make public speaking as possible. 4. Learn theories of phonetics; such as about pronunciation, accent, intonation, prominence, assimilation and so on.

  • PDF

뉴로피드백을 이용한 명상훈련이 정상 성인의 기억과 집중력에 미치는 영향 (The Effects of Breath Meditation with Neurofeedback on Memory and Concentration of Healthy Adult Volunteers)

  • 정선용;서진우;김종우;황의완
    • 동의신경정신과학회지
    • /
    • 제19권2호
    • /
    • pp.15-39
    • /
    • 2008
  • Objective : The objective of this study was to investigate the effects of breath meditation with neurofeedback on memory, concentration of healthy adult volunteers Method 25 healthy adult volunteers were divided into two groups. One group was treated with breath meditation and real neurofeedback, but the other group was administered with breath meditation and sham neurofeedback three times a week for 10 sessions, Before and after 10 sessions neurofeedback, all subjects were measured by cognitive functions assessment, heart rate variability, BDI, STAI, K-WAIS, HRSD, VAS about amnesia. Results : 1. Breath Meditation decreased error rate and increased concentration, cognition strength, and success rate of Cognitive Functions Assessment. Also, Breath Medication elevated IQ score of K-WAIS short form. 2. Sham : neurofeedback increased concentration, cognition strength compared to Real neurofeedback. Conclusion : The results suggest that breath meditation might effect cognitive function of healthy adult positively, but neurofeedback is not clear. In order to prove whether neurofeedback is effective or not, it should be studied more.

  • PDF

Exhaled breath Analysis for Body Burden Estimates of Aromatic Volatile Organic Compounds

  • Jo, Wan-Kuen;Song, Ki-Bum;Nam, Chang-Mo
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권1호
    • /
    • pp.25-29
    • /
    • 2000
  • The present study evaluated the body burden of aromatic VOCs in roadside and underground storekeepers. The Method Detection Limit(MDL) of the analytical system ranged from 0.2 to 0.4$\mu\textrm{g}$/m3 for the target VOCs. The recovery of the sampling system for the compounds was above 80%. For all the target compounds, the breath concentrations of the smokes were similar to or slightly higher than those of the nonsmokers for both the roadside and underground storekeepers. For Ethylbenzene, p-Xylene, and o-Xylene, the breath concentrations of the underground storekeepers were somewhat higher than those of the roadside storekeepers. In contrast, the breath m-xylene concentration of underground storekeepers was similar to that of roadside storekeepers. For both the roadside and underground storekeepers, the breath concentrations prior to and after work were not significantly different.

  • PDF

서미스터를 이용한 호흡유량 바이오센서 (Development of Breath Flow Sensor with Thermistor)

  • 송찬이;배황;장근식;김사지
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.468-471
    • /
    • 2008
  • We have developed a breath flow sensor that is cheap, robust and has reasonable accuracy. It based on using two thermistors implanted in a breath nozzle, apart by a small but known distance. The sensors detect the small time interval when the breath tidal wave passes by. Therefore the speed of the breath gas can be determined in a given pipe of known diameter. The sensors are calibrated for a few parameters and their accuracy has been estimated.

  • PDF

구취가 후각인지도 및 methyl mercaptan에 대한후각감지역치에 미치는 영향 (Effect of Bad Breath on Olfactory Identification Ability and on Olfactory Detection Threshold for CH3SH)

  • 도영환;최재갑;안형준
    • Journal of Oral Medicine and Pain
    • /
    • 제26권4호
    • /
    • pp.309-318
    • /
    • 2001
  • The purposes of the study were (1) to evaluate the olfactory identification ability in those who have bad breath, (2) to determine the olfactory detection threshold for methyl mercaptan in normal subjects and those who have bad breath, and (3) to evaluate the effect of oral hygiene care on the olfactory detection threshold for methyl mercaptan. Sixteen male subjects with bad breath (male odor group), 9 male subjects without bad breath (male non-odor group), and 10 female subjects without bad breath (female non-odor group) were included for the study. Olfactory identification ability was assessed by administrating the Cross-Cultural Smell Identification Test (CC-SIT), and the olfactory detection threshold for methyl mercaptan was measured by two-alternative forced-choice single-staircase detection threshold procedure in a double-blinded condition. The geometric mean of the last four staircase reversal points of a total of seven reversals is used as the threshold. For the male odor group, after 1 month of intensive oral hygiene care for reducing oral volatile sulfur compounds (VSC) concentration, the olfactory detection threshold for methyl mercaptan was measured again and compared to the initial value. The ANOVA was used to test the group difference of olfactory threshold and olfactory identification ability and the paired t-test was used to test the difference of olfactory threshold between before and after reduction of oral VSC in male odor group. The results were as follows : 1. There was no significant difference in olfactory identification ability among those who have bad breath and normal male or female subjects. 2. The olfactory detection threshold for methyl mercaptan was about 8.4 ppb in normal male and female. 3. There was a tendency that male subjects with bad breath showed a higher olfactory detection threshold for methyl mercaptan when compared to those of no bad breath. 4. The olfactory detection threshold for methyl mercaptan returned to a normal level after 1 month of intensive oral hygiene care for reducing oral VSC.

  • PDF

한국무용 걸음체 동작 시 호흡의 사용유무가 하지의 운동역학적 변인에 미치는 영향 (The Effects of Breathing Control on Kinetic Parameters of Lower Limbs during Walking Motion in Korean Dance)

  • 박양선;장지영
    • 한국운동역학회지
    • /
    • 제19권4호
    • /
    • pp.627-636
    • /
    • 2009
  • 본 연구는 한국무용 시 내면의 아름다움뿐만 아니라, 외면으로 표현되고 기술적으로 한층 세분화된 한국무용의 호흡에 대한 중요성을 인식하는 연구의 필요성을 갖고, 호흡의 사용이 한국무용 걸음체 동작에 어떠한 영향을 미치는 가를 분석하여, 무용의 추상적인 아름다움을 과학적인 근거로 명확하게 제공하는 데 연구의 목적을 갖는다. 연구 결과, 호흡을 사용한 걸음체가 호흡을 사용하지 않는 걸음체 보다 신체중심과 골반이 이동변위가 낮게 나타났다. 슬관절과 족관절의 각변위에서 호흡을 사용하는 걸음체가 호흡을 사용하지 않는 걸음체보다 굴곡되어 굽힘이 많이 사용되었고, 이것은 굴신이 일어나고 있는 시전에서 나타났다. 호흡을 사용한 걸음체 동작은 수직지면반력에서 호흡을 사용하지 않은 걸음체에서 볼 수 없는 pre정점이 나타났고 이것은 한국무용 걸음체 시 호흡이 시작되는 들숨의 시점을 의미하며, 뒤꿈치 닿는 구간(1정점)에서 호흡을 사용한 걸음체의 부하 값이 날숨에 의해 호흡을 사용하지 않는 걸음체 보다 부하 값이 더 크게 나타났다. 전후지면반력 결과 호흡을 사용한 걸음체가 제동력이 더욱 크게 나타났다.

Report on Two Cases of Treatment of Anxiety Disorder with Panic Attacks-on the Basis of Breath-Counting Meditation (Anapanasati)

  • Yoo, Song-Wun;Kim, Dong-Uk;Park, Se-Jin
    • 동의신경정신과학회지
    • /
    • 제26권1호
    • /
    • pp.1-10
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate the effect of breath-counting meditation on anxiety disorder patients with panic attack. Methods: Two anxiety disorder patients with panic attack were treated with Breath-counting Meditation, acupunctures, and herb-medications. The patients have been predicted for anxiety disorder with panic attack through Dignosis and Statistical Manual (DSM-IV), Panic Disorder Severity Scale (PDSS), BDI (Beck Depression Inventory), and BAI (Beck Anxiety Inventory) on their 1st and 6th treatments. Results: After the treatments, both the physical and psychological symptoms have decreased. Conclusions: This study suggests that the breath-counting meditation is an effective way for treating patients who are suffering from anxiety disorder with panic attack.

스마트 호기 센서 응용 금속 산화물 반도체 나노입자 연구 동향

  • 유란;이우영
    • 세라미스트
    • /
    • 제21권2호
    • /
    • pp.38-48
    • /
    • 2018
  • This paper reports a comprehensive review of the state-of-the-art in research on the enhancement of sensing properties for the detection of gases in exhaled breath. Daily health monitoring and early diagnosis of specific diseases via the analysis of exhaled breath is possible. Because biomarkers in exhaled breath are emitted in a very small amount, it is necessary to develop highly sensitive gas sensors. In recent years, a number of researches have been carried out using various strategies for the enhancement of sensing properties such as doping, catalyst, hollow sphere, heterojunction, size effect. We introduced each strategy and summarized recent progress on sensing properties for detection of biomarkers in exhaled breath.

Intelligent Electronic Nose System for Detection of VOCs in Exhaled Breath

  • Byun, Hyung-Gi;Yu, Joon-Bu
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.7-12
    • /
    • 2019
  • Significant progress has been made recently in detection of highly sensitive volatile organic compounds (VOCs) using chemical sensors. Combined with the progress in design of micro sensors array and electronic nose systems, these advances enable new applications for detection of extremely low concentrations of breath-related VOCs. State of the art detection technology in turn enables commercial sensor systems for health care applications, with high detection sensitivity and small size, weight and power consumption characteristics. We have been developing an intelligent electronic nose system for detection of VOCs for healthcare breath analysis applications. This paper reviews our contribution to monitoring of respiratory diseases and to diabetic monitoring using an intelligent electronic nose system for detection of low concentration VOCs using breath analysis techniques.

Analysis of Acetone Absorption Spectra Using Off-axis Integrated Cavity Output Spectroscopy for a Real-time Breath Test

  • Lim Lee;Yonghee Kim;Byung Jae Chun;Taek-Soo Kim;Seung-Kyu Park;Kwang-Hoon Ko;Ki-Hee Song;Hyunmin Park
    • Current Optics and Photonics
    • /
    • 제7권6호
    • /
    • pp.761-765
    • /
    • 2023
  • We analyzed the absorption spectra of acetone in the 3.37 ㎛ mid-infrared range using the off-axis integrated cavity output spectroscopy technique to develop a real-time, in-line breath analysis device. The linear relationship between acetone concentration and absorption increase was confirmed as 0.32%/ppm, indicating that the developed device allows for a quantitative analysis of acetone concentration in exhaled breath. To further confirm the feasibility of using our device for breath analysis, we measured the acetone concentration of human breath samples at the sub-ppm level.