• Title/Summary/Keyword: breast ultrasound

Search Result 144, Processing Time 0.03 seconds

Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound

  • Su Min Ha;Jung Min Chang;Su Hyun Lee;Eun Sil Kim;Soo-Yeon Kim;Yeon Soo Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.867-879
    • /
    • 2021
  • Objective: To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. Materials and Methods: Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. Results: Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). Conclusion: In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

Screening in the Era of Economic Crisis: Misperceptions and Misuse from a Longitudinal Study on Greek Women Undergoing Benign Vacuum-assisted Breast Biopsy

  • Domeyer, Philip John;Sergentanis, Theodoros Nikolaos;Katsari, Vasiliki;Souliotis, Kyriakos;Mariolis, Anargiros;Zagouri, Flora;Zografos, George Constantine
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5023-5029
    • /
    • 2013
  • Background: To evaluate knowledge about screening tests and tests without proven screening value in a Greek Breast Unit population undergoing benign vacuum-assisted breast biopsy (VABB). Materials and Methods: This study included 81 patients. Three knowledge-oriented items (recommended or not, screening frequency, age of onset) were assessed. Regarding screening tests two levels of knowledge were evaluated: i). crude knowledge (CK), i.e. knowledge that the test is recommended and ii). advanced knowledge (AK), i.e. correct response to all three knowledge-oriented items. Solely CK was evaluated for tests without proven screening value. Risk factors for lack of knowledge were assessed with multivariate logistic regression. A second questionnaire was administered 18 months after VABB to assess its impact on the performance of tests. Results: Concerning screening tests considerable lack of AK was noted (mammogram, 60.5%; Pap smear, 59.3%; fecal occult blood testing, 93.8%; sigmoidoscopy, 95.1%). Similarly lack of CK was documented regarding tests without proven screening value (breast self-examination, 92.6%; breast MRI, 60.5%; abdominal ultrasound, 71.6%; barium meal, 48.1%; urine analysis, 90.1%; chest X-Ray, 69.1%; electrocardiogram, 74.1%; cardiac ultrasound, 75.3%). Risk factors for lack of AK were: place of residence (mammogram), age (Pap smear), personal income (sigmoidoscopy); risk factors for lack of CK included number of offspring (breast MRI, chest X-Ray), BMI (abdominal ultrasound), marital status (urine analysis), current smoking status (electrocardiogram). VABB's only effect was improvement in mammogram rates. Conclusions: A considerable lack of knowledge concerning screening tests and misperceptions regarding those without proven value was documented.

Outcome and Cost Effectiveness of Ultrasonographically Guided Surgical Clip Placement for Tumor Localization in Patients undergoing Neo-adjuvant Chemotherapy for Breast Cancer

  • Masroor, Imrana;Zeeshan, Sana;Afzal, Shaista;Sufian, Saira Naz;Ali, Madeeha;Khan, Shaista;Ahmad, Khabir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8339-8343
    • /
    • 2016
  • Background: To determine the outcome and cost saving by placing ultrasound guided surgical clips for tumor localization in patients undergoing neo-adjuvant chemotherapy for breast cancer. Materials and Methods: This retrospective cross sectional analytical study was conducted at the Department of Diagnostic Radiology, Aga Khan University Hospital, Karachi, Pakistan from January to December 2014. A sample of 25 women fulfilling our selection criteria was taken. All patients came to our department for ultrasound guided core biopsy of suspicious breast lesions and clip placement in the index lesion prior to neo-adjuvant chemotherapy. All the selected patients had biopsy proven breast cancer. Results: The mean age was $45{\pm}11.6years$. There were no complications seen after clip placement in terms of clip migration or hemorrhage. The cost of commercially available markers was approximately PKR 9,000 (US$ 90) and that of the surgical clip was PKR 900 (US$ 9). The cost of surgical clips in 25 patients was PKR 22,500 (US$ 225), when compared to the commercially available markers which may have incurred a cost of PKR 225,000 (US$ 2,250). The total cost saving for 25 patients was PKR 202,500 (US$ 2, 025), making it PKR 8100 (US$ 81) per patient. Conclusions: The results of our study show that ultrasound guided surgical clip placement in index lesions prior to neo-adjuvant therapy is a safe and cost effective method to identify tumor bed and response to treatment for further management.

The analgesic efficacy of a single injection of ultrasound-guided retrolaminar paravertebral block for breast surgery: a prospective, randomized, double-blinded study

  • Hwang, Boo-Young;Kim, Eunsoo;Kwon, Jae-young;Lee, Ji-youn;Lee, Dowon;Park, Eun Ji;Kang, Taewoo
    • The Korean Journal of Pain
    • /
    • v.33 no.4
    • /
    • pp.378-385
    • /
    • 2020
  • Background: The thoracic paravertebral block is an effective analgesic technique for postoperative pain management after breast surgery. The ultrasound-guided retrolaminar block (RLB) is a safer alternative to conventional paravertebral block. Thus, we assessed the analgesic efficacy of ultrasound-guided RLB for postoperative pain management after breast surgery. Methods: Patients requiring breast surgery were randomly allocated to group C (retrolaminar injection with saline) and group R (RLB with local anesthetic mixture). The RLB was performed at the level of T3 with local anesthetic mixture (0.75% ropivacaine 20 mL + 2% lidocaine 10 mL) under general anesthesia before the skin incision. The primary outcome was cumulative morphine consumption using intravenous patient-controlled analgesia (IV-PCA) at 24 hour postoperatively. The secondary outcomes were the visual analogue scale (VAS) scores at 1, 6, 24, and 48 hour postoperatively and the occurrence of adverse events and patient satisfaction after the surgery. Results: Forty-six patients were included, 24 in group C and 22 in group R. The cumulative morphine consumption using IV-PCA did not differ between the two groups (P = 0.631). The intraoperative use of remifentanil was higher in group C than in group R (P = 0.025). The resting and coughing VAS scores at 1 hour postoperatively were higher in group R than in group C (P = 0.011, P = 0.004). The incidence of adverse events and patient satisfaction was not significantly different between the two groups. Conclusions: A single injection of ultrasound-guided RLB did not reduce postoperative analgesic requirements following breast surgery.

Application of Computer-Aided Diagnosis a using Texture Feature Analysis Algorithm in Breast US images (유방 초음파영상에서 질감특성분석 알고리즘을 이용한 컴퓨터보조진단의 적용)

  • Lee, Jin-Soo;Kim, Changsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.507-515
    • /
    • 2015
  • This paper suggests 6 cases of TFA parameters algorithm(Mean, VA, RS, SKEW, UN, EN) to search for the detection of recognition rates regarding breast disease using CAD on ultrasound images. Of the patients who visited a university hospital in Busan city from August 2013 to January 2014, 90 cases of breast ultrasound images based on the findings in breast US and pathology were selected. $50{\times}50$ pixel size ROI was selected from the breast US images. After pre-processing histogram equalization of the acquired test images(negative, benign, malignancy), we calculated results of TFA algorithm using MATLAB. As a result, in the TFA parameters suggested, the disease recognition rates for negative and malignancy was as high as 100%, and negative and benign was approximately 83~96% for the Mean, SKEW, UN, and EN. Therefore, there is the possibility of auto diagnosis as a pre-processing step for a screening test on breast disease. A additional study of the suggested algorithm and the responsibility and reproducibility for various clinical cases will determine the practical CAD and it might be possible to apply this technique to range of ultrasound images.

Comparison of Automated Breast Volume Scanning and Hand-Held Ultrasound in the Detection of Breast Cancer: an Analysis of 5,566 Patient Evaluations

  • Choi, Woo Jung;Cha, Joo Hee;Kim, Hak Hee;Shin, Hee Jung;Kim, Hyunji;Chae, Eun Young;Hong, Min Ji
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9101-9105
    • /
    • 2014
  • Background: The purpose of this study was to compare the accuracy and effectiveness of automated breast volume scanning (ABVS) and hand-held ultrasound (HHUS) in the detection of breast cancer in a large population group with a long-term follow-up, and to investigate whether different ultrasound systems may influence the estimation of cancer detection. Materials and Methods: Institutional review board approval was obtained for this retrospective study, and informed consent was waived. From September 2010 to August 2011, a total of 1,866 ABVS and 3,700 HHUS participants, who underwent these procedures at our institute, were included in this study. Cancers occurring during the study and subsequent follow-up were evaluated. The reference standard was a combination of histology and follow-up imaging (${\geq}12months$). The recall rate, cancer detection yield, diagnostic accuracy, sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values were calculated with exact 95% confidence intervals. Results: The recall rate was 2.57 per 1,000 (48/1,866) for ABVS and 3.57 per 1,000 (132/3,700) for HHUS, with a significant difference (p=0.048). The cancer detection yield was 3.8 per 1,000 for ABVS and 2.7 per 1,000 for HHUS. The diagnostic accuracy was 97.7% for ABVS and 96.5% for HHUS with statistical significance (p=0.018). The specificity of ABVS and HHUS were 97.8%, 96.7%, respectively (p=0.022). Conclusions: ABVS shows a comparable diagnostic performance to HHUS. ABVS is an effective supplemental tool for mammography in breast cancer detection in a large population.

A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography (유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구)

  • Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.751-759
    • /
    • 2023
  • Breast ultrasonography is difficult to image in fatty breasts and to find micro-calcification, but the discovery of micro-calcification is very important for breast cancer screening. Among the color Doppler artifact of ultrasound, twinkle artifact mainly occur on strong reflectors such as stones or calcification in images, and evaluation methods using them are clinically being used. In this study, we are conducting experiments on the color Doppler settings of ultrasound equipment, such as repetition frequency, ensemble, persist, wall filtering, smoothing, linear density, and dissociation value, by producing a breast simulation phantom using the largest amount of calcium phosphate among breast implants. The purpose of this study was to improve the contrast of twinkle artifact in breast ultrasound examinations and to maximize their use in clinical practice. As a result, the pulse repetition frequency occurred in the range of 3.6 kHz to 7.2 kHz, and did not occur above 10.5 kHz. For ensembles, twinkle artifact occurred in all sizes of calcification under low conditions, and in threshold settings, the twinkle artifact increased slightly only under 80 to 100 conditions, and did not occur in 1 mm size calcification. Persist, wall filter, smoothing, and line density settings did not have much meaning in the setting variable because conditions did not increase by condition, and pulse repetition frequency, ensemble, and thresholds had the greatest impact on the twinkling artifact image. This study is expected to help examiners select optimal conditions to effectively increase twinkle artifact by adjusting color Doppler settings.

A Prospective Study on the Value of Ultrasound Microflow Assessment to Distinguish Malignant from Benign Solid Breast Masses: Association between Ultrasound Parameters and Histologic Microvessel Densities

  • Ah Young Park;Myoungae Kwon;Ok Hee Woo;Kyu Ran Cho;Eun Kyung Park;Sang Hoon Cha;Sung Eun Song;Ju-Han Lee;JaeHyung Cha;Gil Soo Son;Bo Kyoung Seo
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.759-772
    • /
    • 2019
  • Objective: To investigate the value of ultrasound (US) microflow assessment in distinguishing malignant from benign solid breast masses as well as the association between US parameters and histologic microvessel density (MVD). Materials and Methods: Ninety-eight breast masses (57 benign and 41 malignant) were examined using Superb Microvascular Imaging (SMI) and contrast-enhanced US (CEUS) before biopsy. Two radiologists evaluated the quantitative and qualitative vascular parameters on SMI (vascular index, morphology, distribution, and penetration) and CEUS (time-intensity curve analysis and enhancement characteristics). US parameters were compared between benign and malignant masses and the diagnostic performance was compared between SMI and CEUS. Subgroup analysis was performed according to lesion size. The effect of vascular parameters on downgrading Breast Imaging Reporting and Data System (BI-RADS) category 4A masses was evaluated. The association between histologic MVD and US parameters was analyzed. Results: Malignant masses were associated with a higher vascular index (15.1 ± 7.3 vs. 5.9 ± 5.6), complex vessel morphology (82.9% vs. 42.1%), central vascularity (95.1% vs. 59.6%), penetrating vessels (80.5% vs. 31.6%) on SMI (all, p < 0.001), as well as higher peak intensity (37.1 ± 25.7 vs. 17.0 ± 15.8, p < 0.001), slope (10.6 ± 11.2 vs. 3.9 ± 4.2, p = 0.001), area (1035.7 ± 726.9 vs. 458.2 ± 410.2, p < 0.001), hyperenhancement (95.1% vs. 70.2%, p = 0.005), centripetal enhancement (70.7% vs. 45.6%, p = 0.023), penetrating vessels (65.9% vs. 22.8%, p < 0.001), and perfusion defects (31.7% vs. 3.5%, p < 0.001) on CEUS (p ≤ 0.023). The areas under the receiver operating characteristic curve (AUCs) of SMI and CEUS were 0.853 and 0.841, respectively (p = 0.803). In 19 masses measuring < 10 mm, central vascularity on SMI was associated with malignancy (100% vs. 38.5%, p = 0.018). Considering all benign SMI parameters on the BI-RADS assessment, unnecessary biopsies could be avoided in 12 category 4A masses with improved AUCs (0.500 vs. 0.605, p < 0.001). US vascular parameters associated with malignancy showed higher MVD (p ≤ 0.016). MVD was higher in malignant masses than in benign masses, and malignant masses negative for estrogen receptor or positive for Ki67 had higher MVD (p < 0.05). Conclusion: US microflow assessment using SMI and CEUS is valuable in distinguishing malignant from benign solid breast masses, and US vascular parameters are associated with histologic MVD.

Combination of Quantitative Parameters of Shear Wave Elastography and Superb Microvascular Imaging to Evaluate Breast Masses

  • Eun Ji Lee;Yun-Woo Chang
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1045-1054
    • /
    • 2020
  • Objective: This study aimed to evaluate the diagnostic value of combining the quantitative parameters of shear wave elastography (SWE) and superb microvascular imaging (SMI) to breast ultrasound (US) to differentiate between benign and malignant breast masses. Materials and Methods: A total of 200 pathologically confirmed breast lesions in 192 patients were retrospectively reviewed using breast US with B-mode imaging, SWE, and SMI. Breast masses were assessed based on the breast imaging reporting and data system (BI-RADS) and quantitative parameters using the maximum elasticity (Emax) and ratio (Eratio) in SWE and the vascular index in SMI (SMIVI). The area under the receiver operating characteristic curve (AUC) value, sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of B-mode alone versus the combination of B-mode US with SWE or SMI of both parameters in differentiating between benign and malignant breast masses was compared, respectively. Hypothetical performances of selective downgrading of BI-RADS category 4a (set 1) and both upgrading of category 3 and downgrading of category 4a (set 2) were calculated. Results: Emax with a cutoff value of 86.45 kPa had the highest AUC value compared to Eratio of 3.57 or SMIVI of 3.35%. In set 1, the combination of B-mode with Emax or SMIVI had a significantly higher AUC value (0.829 and 0.778, respectively) than B-mode alone (0.719) (p < 0.001 and p = 0.047, respectively). B-mode US with the addition of Emax, Eratio, and SMIVI had the best diagnostic performance of AUC value (0.849). The accuracy and specificity increased significantly from 68.0% to 84.0% (p < 0.001) and from 46.1% to 79.1% (p < 0.001), respectively, and the sensitivity decreased from 97.6% to 90.6% without statistical loss (p = 0.199). Conclusion: Combining all quantitative values of SWE and SMI with B-mode US improved the diagnostic performance in differentiating between benign and malignant breast lesions.

A Study on the Development of Ultrasonography Guide using Motion Tracking System (이미지 가이드 시스템 기반 초음파 검사 교육 기법 개발: 예비 연구)

  • Jung Young-Jin;Kim Eun-Hye;Choi Hye-Rin;Lee Chae-Jeong;Kim Seo-Hyeon;Choi Yu-Jin;Hong Dong-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1067-1073
    • /
    • 2023
  • Breast cancer is one of the top three most common cancers in modern women, and the incidence rate is increasing rapidly. Breast cancer has a high family history and a mortality rate of about 15%, making it a high-risk group. Therefore, breast cancer needs constant management after an early examination. Among the various equipment that can diagnose cancer, ultrasound has the advantage of low risk and being able to diagnose in real time. In addition, breast ultrasound will be more useful because Asian women's breasts are denser and less sensitive. However, the results of ultrasound examinations vary greatly depending on the technology of the examiner. To compensate for this, we intend to incorporate motion tracking technology. Motion tracking is a technology that specifies and analyzes a location according to the movement of an object in a three-dimensional space. Therefore, real-time control is possible, and complex and fast movements can be recorded in real time. We would like to present the production of an ultrasound examination guide using these advantages.