• Title/Summary/Keyword: breast cancer patient's

Search Result 187, Processing Time 0.032 seconds

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

circRNA circSnx12 confers Cisplatin chemoresistance to ovarian cancer by inhibiting ferroptosis through a miR-194-5p/SLC7A11 axis

  • Kaiyun Qin;Fenghua Zhang;Hongxia Wang;Na Wang;Hongbing Qiu;Xinzhuan Jia;Shan Gong;Zhengmao Zhang
    • BMB Reports
    • /
    • v.56 no.3
    • /
    • pp.184-189
    • /
    • 2023
  • Ovarian cancer (OC) is the most common gynecological malignancy worldwide, and chemoresistance occurs in most patients, resulting in treatment failure. A better understanding of the molecular processes underlying drug resistance is crucial for development of efficient therapies to improve OC patient outcomes. Circular RNAs (circRNAs) and ferroptosis play crucial roles in tumorigenesis and resistance to chemotherapy. However, little is known about the role(s) of circRNAs in regulating ferroptosis in OC. To gain insights into cisplatin resistance in OC, we studied the ferroptosis-associated circRNA circSnx12. We evaluated circSnx12 expression in OC cell lines and tissues that were susceptible or resistant to cisplatin using quantitative real-time PCR. We also conducted in vitro and in vivo assays examining the function and mechanism of lnc-LBCSs. Knockdown of circSnx12 rendered cisplatin-resistant OC cells more sensitive to cisplatin in vitro and in vivo by activating ferroptosis, which was at least partially abolished by downregulation of miR-194-5p. Molecular mechanics studies indicate that circSnx12 can be a molecular sponge of miR-194-5p, which targets SLC7A11. According to our findings, circSnx12 ameliorates cisplatin resistance by blocking ferroptosis via a miR-194-5p/SLC7A11 pathway. CircARNT2 may thus serve as an effective therapeutic target for overcoming cisplatin resistance in OC.

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

Spatial Analysis of Colorectal Cancer Cases in Kuala Lumpur

  • Shah, Shamsul Azhar;Neoh, Hui-Min;Syed Abdul Rahim, Syed Sharizman;Azhar, Zahir Izuan;Hassan, Mohd Rohaizat;Safian, Nazarudin;Jamal, Rahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.3
    • /
    • pp.1149-1154
    • /
    • 2014
  • Background: In Malaysia, data from the Malaysian Health Ministry showed colorectal cancer (CRC) to be the second most common type of cancer in 2007-2009, after breast cancer. The same was apparent after looking at males and females cases separately. In the present study, the Geographic Information System (GIS) was employed to describe the distribution of CRC cases in Kuala Lumpur (KL), Malaysia, according to socio-demographic factors (age, gender, ethnicity and district). Materials and Methods: This retrospective review concerned data for patients diagnosed with colorectal cancer in the years 1995 to 2011 collected from the Wilayah Persekutuan Health Office, taken from the cancer notification form (NCR-2), and patient medical records from the Surgical Department, Universiti Kebangsaan Malaysia Medical Centre (UKMMC). A total of 146 cases were analyzed. All the data collected were analysed using ArcGIS version 10.0 and SPSS version 19.0. Results: Patients aged 60 to 69 years accounted for the highest proportion of cases (34.2%) and males slightly predominated 76 (52.1%), Chinese had the highest number of registered cases at 108 (74.0%) and staging revealed most cases in the 3rd and 4th stages. Kernel density analysis showed more cases are concentrated up in the northern area of Petaling and Kuala Lumpur subdistricts. Spatial global pattern analysis by average nearest neighbour resulted in nearest neighbour ratio of 0.75, with Z-score of -5.59, p value of <0.01 and the z-score of -5.59. Spatial autocorrelation (Moran's I) showed clustering significant with p<0.01, Z score 3.14 and Moran's Index of 0.007. When mapping clusters with hotspot analysis (Getis-Ord Gi), hot and cold spots were identified. Hot spot areas fell on the northeast side of KL. Conclusions: This study demonstrated significant spatial patterns of cancer incidence in KL. Knowledge about these spatial patterns can provide useful information to policymakers in the planning of screening of CRC in the targeted population and improvement of healthcare facilities to provide better treatment for CRC patients.

A Case Report of Osuyubujaijung-tang on the Recurrence of Breast Cancer in a Patient Complaining of Coldness and Dizziness (유방암 재발 환자의 장궐 및 현훈이 오수유부자이중탕으로 호전된 치험 1례)

  • U-ryeong Chung;Soo-hwa Hong;Han-sol Jang;Seung-hyun Jung
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.3
    • /
    • pp.555-561
    • /
    • 2023
  • A 63-year-old female patient was admitted to the hospital with complaints of coldness in the head and right femur, persistent vertigo, dry mouth, vexation, general weakness, anorexia, and hot flashes. After being diagnosed with left-sided ductal carcinoma in 2017 and undergoing partial resection, she was recommended radiotherapy, chemotherapy, and hormone therapy, but she refused and did not receive any treatment. At a checkup in November 2022, the left-sided invasive ductal carcinoma recurred. She underwent partial resection and was scheduled to receive radiotherapy two months later. During hospitalization, the patient received traditional Korean medicine treatment, including Korean herbal medicine (Osuyubujaijung-tang), acupuncture, moxibustion, and cupping. Subjective symptom changes were evaluated daily. At discharge, the patient's symptoms improved, and her condition varied with the presence of Aconitum carmichaelii. This study suggests that "Osuyubujaijung-tang" cared the coldness and vertigo caused by "Han-dam (寒痰)" in patients with Soeumin visceral syncope pattern (少陰人 臟厥症) and that A. carmichaelii played a major role in this outcome.

The 1998, 1999 Patterns of Care Study for Breast Irradiation After Breast-Conserving Surgery in Korea (1998, 1999년도 우리나라에서 시행된 유방보존수술 후 방사선치료 현황 조사)

  • Suh Chang-Ok;Shin Hyun Soo;Cho Jae Ho;Park Won;Ahn Seung Do;Shin Kyung Hwan;Chung Eun Ji;Keum Ki Chang;Ha Sung Whan;Ahn Sung Ja;Kim Woo Cheol;Lee Myung Za;Ahn Ki Jung
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.192-199
    • /
    • 2004
  • Purpose: To determine the patterns on evaluation and treatment in the patient with early breast cancer treated with conservative surgery and radiotherapy and to improve the radiotherapy techiniques, nationwide survey was peformed. Materials and Methods: A web-based database system for korean Patterns of Care Study (PCS) for 6 common cancers was developed. Two hundreds sixty-one randomly selected records of eligible patients treated between 1998$\~$1999 from 15 hospitals were reviewed. Results: The patients ages ranged from 24 to 85 years(median 45 years). Infiltrating ductal carcinoma was most common histologic type (88.9$\%$) followed by medullary carcinoma (4.2$\%$) and infiltrating lobular carcinoma (1.5$\%$). Pathologic T stage by AJCC was T1 in 59.7$\%$ of the casses, T2 in 29.5$\%$ of the cases, Tis in 8.8$\%$ of the cases. Axillary lymph node dissection was peformed I\in 91.2$\%$ of the cases and 69.7$\%$ were node negative. AJCC stage was 0 in 8.8$\%$ of the cases, stage I in 44.9$\%$ of the cases, stage IIa in 33.3$\%$ of the cases, and stage IIb in 8.4$\%$ of the cases. Estrogen and progesteron receptors were evaluated in 71.6$\%$, and 70.9$\%$ of the patients, respectively. Surgical methods of breast-conserving surgery was excision/lumpectomy in 37.2$\%$, wide excision in 11.5$\%$, quadrantectomy in 23$\%$ and partial mastectomy in 27.5$\%$ of the cases. A pathologically confirmed negative margin was obtained in 90.8$\%$ of the cases. Pathological margin was involved with tumor in 10 patients and margin was close (less than 2 mm) in 10 patients. All the patients except one recieved more than 90$\%$ of the planned radiotherapy dose. Radiotherapy volume was breast only In 88$\%$ of the cases, breast+supraclavicular fossa (SCL) in 5$\%$ of the cases, and breast+ SCL+ posterior axillary boost in 4.2%$\%$of the cases. Only one patient received isolated internal mammary lymph node irradiation. Used radiation beam was Co-60 in 8 cases, 4 MV X-ray in 115 cases, 6 MV X-ray in 125 cases, and 10 MV X-ray in 11 cases. The radiation dose to the whole breast was 45$\~$59.4 Gy (median 50.4) and boost dose was 8$\~$20 Gy (median 10 Gy). The total radiation dose delivered was 50.4$\~$70.4 Gy (median 60.4 Gy). Conclusion: There was no major deviation from current standard in the patterns of evaluation and treatment for the patients with early breast cancer treated with breast conservation method. Some varieties were identified in boost irradiation dose. Separate analysis for the datails of radiotherapy planning will be followed and the outcome of treatment is needed to evaluate the process.

Study Protocol for the Most Effective Recall Method in a Cervical Cancer Screening Program in Klang, Malaysia

  • Rashid, Rima Marhayu Abdul;Dahlui, Maznah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5867-5870
    • /
    • 2013
  • Background: Cervical cancer is the second most common cancer among Malaysian women with an ASR of 17.9 and a mortality rate of 5.6 per 100,000 population in 2008 (GLOBOCAN, 2008). The 5 year prevalence was estimated to be 14.5 per 100,000 population. As the second most common cancer affecting productive females, cervical cancer imposes an impact to the socioeconomic aspect of the country. However, the poor uptake of cervical cancer screening is a major problem in detecting early pre-cancerous lesions and thus, delay in initiating treatment for cervical cancer. Realizing the urgency to increase the uptake of PAP smear, besides enhancing the promotion of PAP smear screening for women above 35 years old, the call-recall system for pap smear screening had been piloted in one of the suburban districts which aimed to improve regular participation of women for cervical and breast cancer screening. This is of public health importance as identifying the best feasible option to increase patient's respond to participate in the screening program effectively in our setting will be helpful in implementing an organized regular population based screening program tailored to our setting. The pilot program of cervical cancer screening in Klang was an opportunity to assess different options in recalling patients for a repeat pap smear to increase their participation and adherence to the program. Methods and Results: This was a population based randomized control trial. Women aged 20-65 years in the population that matched the inclusion and exclusion criteria were re-called for a repeat smear. There are four different intervention groups; letter, registered letters, short messages services (SMS) and phone calls where 250 subjects were recruited into each group. Samples were generated randomly from the same population in Klang into four different groups. The first group received a recall letter for a repeat smear similar to the one that has been given during the first invitation. The intervention groups were either be given a registered letter, an SMS or a phone call to re-call them. The socio-demographic data of the patients who came for uptake were collected for further analysis. All the groups were followed up after 8 weeks to assess their compliance to the recall. Conclusions: The study will provide recommendations about the most effective methods for recall in a population based pap smear screening program on two outcomes: i) patients response; ii) uptake for repeat pap smear.

The Effects of Proprioceptive Neuromuscular Facilitation (PNF) Using Elastic Bands on Edema, Range of Motion, and Pain in Post-Mastectomy Patients with Upper Limb Lymphedema: Differences between Open-Hand and Closed-Hand Grips (탄력밴드를 이용한 PNF 운동이 유방암 절제술에 속발한 상지 림프부종 환자의 부종, 관절가동범위 및 통증에 미치는 영향 -열린 홀딩과 닫힌 홀딩의 차이-)

  • Jo, Ye-Jin;Lee, Sang-Yeol
    • PNF and Movement
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • Purpose: This study was conducted to examine the effects of a PNF intervention using elastic bands on edema, range of motion (ROM), and pain in post-mastectomy patients with upper limb lymphedema, according to their hand grip type. Methods: The subjects were 14 female patients who were at Stage II lymphedema after undergoing mastectomy for Stage II breast cancer. They were randomly divided into an experimental group (n =7) and a control group (n = 7). Both groups participated in a treatment program four times (one time under the therapist's instructions and three times as self-exercise) a week for 4 weeks. Both groups repeated an upper limb PNF pattern exercise for 30 min using elastic bands after receiving a manual lymph drainage treatment for 1 hour. Here, subjects in the experimental group performed the PNF exercise with an open-hand grip by putting their hands into the loops of elastic bands and keeping their fingers spread out. Subjects in the control group performed the PNF exercise with a closed-hand grip by holding the loops of elastic bands with their fingers. In both groups, the subjects' edema, ROM, and pain levels were measured before the intervention and 2, 3 and 4 weeks after the intervention. Results: As a result of the experiment, both groups demonstrated edema reductions, ROM increases, and pain reductions in four areas of the upper limbs. Notably, the experimental group exhibited larger ROM increases in flexion, extension, and abduction as well as greater edema and pain reductions than the control group. In particular, the most significant effects were found in the elbow of the four upper limb areas for edema reductions and in extension for ROM increases. Conclusion: The present study indicates that exercise therapy-based approaches using elastic bands in post-mastectomy patients with upper limb lymphedema can have different effects depending on the type of hand grip (open or closed), which is the body's most distal part. Therefore, these approaches should be based on the conditions of the distal parts of the patient's body for their effective applications in clinical practice.

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF