Digital Breast Tomosynthesis versus MRI as an Adjunct to Full-Field Digital Mammography for Preoperative Evaluation of Breast Cancer according to Mammographic Density

  • Haejung Kim;So Yeon Yang;Joong Hyun Ahn;Eun Young Ko;Eun Sook Ko;Boo-Kyung Han;Ji Soo Choi
    • Korean Journal of Radiology
    • /
    • 제23권11호
    • /
    • pp.1031-1043
    • /
    • 2022
  • Objective: To compare digital breast tomosynthesis (DBT) and MRI as an adjunct to full-field digital mammography (FFDM) for the preoperative evaluation of women with breast cancer based on mammographic density. Materials and Methods: This retrospective study enrolled 280 patients with breast cancer who had undergone FFDM, DBT, and MRI for preoperative local tumor staging. Three radiologists independently sought the index cancer and additional ipsilateral and contralateral breast cancers using either FFDM alone, DBT plus FFDM, or MRI plus FFDM. Diagnostic performances across the three radiologists were compared among the reading modes in all patients and subgroups with dense (n = 186) and non-dense breasts (n = 94) according to mammographic density. Results: Of 280 patients, 46 (16.4%) had 48 additional (39 ipsilateral and nine contralateral) cancers in addition to the index cancer. For index cancers, both DBT plus FFDM and MRI plus FFDM showed sensitivities of 100% in the non-dense group. In the dense group, DBT plus FFDM showed lower sensitivity than that of MRI plus FFDM (94.6% vs. 99.6%, p < 0.001). For additional ipsilateral cancers, DBT plus FFDM showed specificity and positive predictive value (PPV) of 100% in the non-dense group, but sensitivity and negative predictive value (NPV) were not statistically different from those of MRI plus FFDM (p > 0.05). In the dense group, DBT plus FFDM showed higher specificity (98.2% vs. 94.1%, p = 0.005) and PPV (83.1% vs. 65.4%; p = 0.036) than those of MRI plus FFDM, but lower sensitivity (59.9% vs. 75.3%; p = 0.049). For contralateral cancers, DBT plus FFDM showed higher specificity than that of MRI plus FFDM (99.0% vs. 96.7%, p = 0.014), however, the other values did not differ (all p > 0.05) in the dense group. Conclusion: DBT plus FFDM showed an overall higher specificity than that of MRI plus FFDM regardless of breast density, perhaps without substantial loss in sensitivity and NPV in the diagnosis of additional cancers. Thus, DBT may have the potential to be used as a preoperative breast cancer staging tool.

유방암 환자의 Digital Mammography에 관한 연구 (A Study on the Digital Mammography for Breast Cancer Patients)

  • 임청환;이상호;정홍량;모은희
    • 한국방사선학회논문지
    • /
    • 제6권1호
    • /
    • pp.63-71
    • /
    • 2012
  • 본 연구는 유방영상검사의 최고의 관심영역인 DR 방식의 유방영상에서 유방암 진단의 정확도를 평가하고, 유방암 환자들의 특성을 알아보고자 DR 방식으로 유방영상검사를 실시한 유방암 환자 57명을 대상으로 2010년 5월부터 2011년 6월까지 조사되었다. 유방암 환자들의 평균 나이는 50.8세이었고, 유방암의 발생 부위는 상외측(UOQ)이 전체의 33.3%로 가장 많은 것으로 조사되었다. 연령에 따른 유방암 발생은 40-49세에서 42.1%로 모든 연령대에서 가장 높게 나타났다. 유방암 환자들의 유방조직 밀도는 지방형 유방이 31.6%(18/57), 치밀유방이 68.4%(39/57)로 나타나, 70%에 가까운 유방암 환자들이 치밀유방의 형태를 띠고 있었다. 유방영상에서 방사선학적 병변 중 종괴와 미세석회화가 함께 동반된 경우 (45.3%)가 유방암 발견율이 가장 높은 것으로 조사되었고, 치밀유방에서 미세석회화를 동반하지 않는 종괴의 경우 지방형 유방에서보다 유방암의 발견율이 더 낮은 것으로 조사되었으며, 이러한 종괴는 치밀유방에서 위음성율을 높이는 원인이 되고 있다. Digital mammography의 위음성률은 7.0%이었고, 민감도는 93.0%인 것으로 조사되었다. 치밀유방의 위음성율은 12.8%, 민감도는 87.2%로 조사되었는데 이는 이전에 보고된 screen film mammography의 치밀유방에서 보다 유방암에 대한 민감도가 더 높은 것으로 조사되었다.

유방암에서 $^{18}F-FDG$ PET의 임상 이용 (Clinical Application of $^{18}F-FDG$ PET in Breast Cancer)

  • 윤준기
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.76-90
    • /
    • 2008
  • $^{18}F-FDG$ PET in combination with conventional imaging modalities could help avoid unnecessary biopsy for the primary mass, and it also has a high diagnostic accuracy in patients with dense breasts. In the assessment of metastasis, $^{18}F-FDG$ PET was useful to select patients who required sentinel lymph node biopsy and to detect extra-axillary lymph node metastasis and distant metastasis. To increase the sensitivity for osteoblastic bone metastasis, bone scintigraphy should be added. In the detection of recurrence, $^{18}F-FDG$ PET showed a higher diagnostic accuracy than tumor marker or computed tomography, and therefore it can be used in routine breast cancer follow-up. $^{18}F-FDG$ PET has been reported that it correctly predicted the response of neoadjuvant chemotherapy on as early as 8th day of treatment. Therefore, it is useful for the early detect of therapeutic response in advanced breast cancer.

Advances in Optimal Detection of Cancer by Image Processing; Experience with Lung and Breast Cancers

  • Mohammadzadeh, Zeinab;Safdari, Reza;Ghazisaeidi, Marjan;Davoodi, Somayeh;Azadmanjir, Zahra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권14호
    • /
    • pp.5613-5618
    • /
    • 2015
  • Clinicians should looking for techniques that helps to early diagnosis of cancer, because early cancer detection is critical to increase survival and cost effectiveness of treatment, and as a result decrease mortality rate. Medical images are the most important tools to provide assistance. However, medical images have some limitations for optimal detection of some neoplasias, originating either from the imaging techniques themselves, or from human visual or intellectual capacity. Image processing techniques are allowing earlier detection of abnormalities and treatment monitoring. Because the time is a very important factor in cancer treatment, especially in cancers such as the lung and breast, imaging techniques are used to accelerate diagnosis more than with other cancers. In this paper, we outline experience in use of image processing techniques for lung and breast cancer diagnosis. Looking at the experience gained will help specialists to choose the appropriate technique for optimization of diagnosis through medical imaging.

Synthesis and Evaluation of 2-[123I]iodoemodin for a Potential Breast Cancer Imaging Agent

  • Park, Jeong-Hoon;Kim, Sang-Wook;Yang, Seung-Dae;Hur, Min-Goo;Chun, Kwon-Soo;Yu, Kook-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권3호
    • /
    • pp.595-598
    • /
    • 2008
  • Emodin (3-methyl-1,6,8-trihydroxyanthraquinone) is a natural chemotherapeutic compound with diverse biological properties including an antitumor activity. Emodin, a specific inhibitor of the protein tyrosine kinase, has a number of cellular targets in related to it. Its inhibition activity affects the mammalian cell cycle regulation in specific oncogene. Practically, it has been proven to inhibit HER-2/neu tyrosine kinase expressing breast cancer cells as an anticancer agent. 2-[123I]iodoemodin has been synthesized and evaluated human breast cancer cells (MDA-MB-231, MCF-7, fibroblast as a control) which express basal levels of HER-2/neu tyrosine kinase to investigate its suitability as a breast cancer imaging agent and 2-iodoemodin has been synthesized as a standard compound. The radiochemical yield of the 2-[123I]iodoemodin was about 72% and its radiochemical purity was over 97% after purification. The radioactivity of the 2-[123I]iodoemodin was increased in a time dependent manner in both cell lines and the ratio of MDA-MB-231 and MCF7 to fibroblast was 2.9 and 1.7, respectively.

MRI-guided Wire Localization Open Biopsy is Safe and Effective for Suspicious Cancer on Breast MRI

  • Wang, Hai-Yi;Zhao, Yu-Nian;Wu, Jian-Zhong;Wang, Zheng;Tang, Jing-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.1715-1718
    • /
    • 2015
  • Background: Magnetic resonance imaging of breast, reported to be a high sensitivity of 94% to 100%, is the most sensitive method for detection of breast cancer. The purpose of this study was to investigate our clinical experience in MRI-guided breast lesion wire localization in Chinese women. Materials and Methods: A total of 44 patients with 46 lesions undergoing MRI-guided breast lesion localization were prospectively entered into this study between November 2013 and September 2014. Samples were collected using a 1.5-T magnet with a special MR biopsy positioning frame device. We evaluated clinical lesion characteristics on pre-biopsy MRI, pathologic results, and dynamic curve type baseline analysis. Results: Of the total of 46 wire localization excision biopsied lesions carried out in 44 female patients, pathology revealed fourteen malignancies (14/46, 30.4%) and thirty-two benign lesions (32/46, 69.6%). All lesions were successfully localized followed by excision biopsy and assessed for morphologic features highly suggestive of malignancy according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category of MRI (C4a=18, C4b=17, C4c=8,C5=3). Of 46 lesions, 37 were masses and 9 were non-mass enhancement lesions. Thirty-two lesions showed a continuous kinetics curve, 11 were plateau and 3 were washout. Conclusions: Our study showed success in MRI-guided breast lesion wire localization with a satisfactory cancer diagnosis rate of 30.4%. MRI-guided wire localization breast lesion open biopsy is a safe and effective tool for the workup of suspicious lesions seen on breast MRI alone without major complications. This may contribute to increasing the diagnosis rate of early breast cancer and improve the prognosis in Chinese women.

Development of Two-Component Nanorod Complex for Dual-Fluorescence Imaging and siRNA Delivery

  • Choi, Jin-Ha;Oh, Byung-Keun
    • Journal of Microbiology and Biotechnology
    • /
    • 제24권9호
    • /
    • pp.1291-1299
    • /
    • 2014
  • Recently, multifunctional nanomaterials have been developed as nanotherapeutic agents for cellular imaging and targeted cancer treatment because of their ease of synthesis and low cytotoxicity. In this study, we developed a multifunctional, two-component nanorod consisting of gold (Au) and nickel (Ni) blocks that enables dual-fluorescence imaging and the targeted delivery of small interfering RNA (siRNA) to improve cancer treatment. Fluorescein isothiocyanate-labeled luteinizing hormone-releasing hormone (LHRH) peptides were attached to the surface of a Ni block via a histidine-tagged LHRH interaction to specifically bind to a breast cancer cell line, MCF-7. The Au block was modified with TAMRA-labeled thiolated siRNA in order to knock down the vascular endothelial growth factor protein to inhibit cancer growth. These two-component nanorods actively targeted and internalized into MCF-7 cells to induce apoptosis through RNA interference. This study demonstrates the feasibility of using two-component nanorods as a potential theranostic in breast cancer treatment, with capabilities in dual imaging and targeted gene delivery.

Comparison of Mammography in Combination with Breast Ultrasonography Versus Mammography Alone for Breast Cancer Screening in Asymptomatic Women

  • Boonlikit, Sarawan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7731-7736
    • /
    • 2013
  • Aim: To compare the agreement of screening breast mammography plus ultrasound and reviewed mammography alone in asymptomatic women. Materials and Methods: All breast imaging data were obtained for women who presented for routine medical checkup at National Cancer Institute (NCI), Thailand from January 2010 to June 2013. A radiologist performed masked interpretations of selected mammographic images retrieved from the computer imaging database. Previous mammography, ultrasound reports and clinical data were blinded before film re-interpretation. Kappa values were calculated to assess the agreement between BIRADS assessment category and BIRADS classification of density obtained from the mammography with ultrasound in imaging database and reviewed mammography alone. Results: Regarding BIRADS assessment category, concordance between the two interpretations were good. Observed agreement was 96.1%. There was moderate agreement in which the Kappa value was 0.58% (95%CI; 0.45, 0.87). The agreement of BI-RADS classification of density was substantial, with a Kappa value of 0.60 (95%CI; 0.54, 0.66). Different results were obtained when a subgroup of patients aged ${\geq}60$ years were analyzed. In women in this group, observed agreement was 97.6%. There was also substantial agreement in which the Kappa value was 0.74% (95%CI; 0.49, 0.98). Conclusions: The present study revealed that concordance between mammography plus ultrasound and reviewed mammography alone in asymptomatic women is good. However, there is just moderate agreement which can be enhanced if age-targeted breast imaging is performed. Substantial agreement can be achieved in women aged ${\geq}60$. Adjunctive breast ultrasound is less important in women in this group.

Diagnostic Value of Contrast-Enhanced Digital Mammography versus Contrast-Enhanced Magnetic Resonance Imaging for the Preoperative Evaluation of Breast Cancer

  • Kim, Eun Young;Youn, Inyoung;Lee, Kwan Ho;Yun, Ji-Sup;Park, Yong Lai;Park, Chan Heun;Moon, Juhee;Choi, Seon Hyeong;Choi, Yoon Jung;Ham, Soo-Youn;Kook, Shin Ho
    • Journal of Breast Cancer
    • /
    • 제21권4호
    • /
    • pp.453-462
    • /
    • 2018
  • Purpose: This study aimed to compare the diagnostic performance of contrast-enhanced digital mammography (CEDM) and contrast-enhanced magnetic resonance imaging (CEMRI) in preoperative evaluations, and to evaluate the effect of each modality on the surgical management of women with breast cancer. Methods: This single-center, prospective study was approved by the Institutional Review Board, and informed consent was obtained from all patients. From November 2016 to October 2017, 84 patients who were diagnosed with invasive carcinoma (69/84) and ductal carcinoma in situ (15/84), and underwent both CEDM and CEMRI, were enrolled. Imaging findings and surgical management were correlated with pathological results and compared. The diagnostic performance of both modalities in the detection of index and secondary cancers (multifocality and multicentricity), and occult cancer in the contralateral breast, was compared. The authors also evaluated whether CEDM or CEMRI resulted in changes in the surgical management of the affected breast due to imaging-detected findings. Results: Eighty-four women were included in the analysis. Compared with CEMRI, CEDM demonstrated a similar sensitivity (92.9% [78/84] vs. 95.2% [80/84]) in detecting index cancer (p=0.563). For the detection of secondary cancers in the ipsilateral breast and occult cancer in the contralateral breast, no significant differences were found between CEDM and CEMRI (p=0.999 and p=0.999, respectively). Regarding changes in surgical management, CEDM resulted in similar changes compared with CEMRI (30.9% [26/84] vs. 29.7% [25/84], p=0.610). Regarding changes in surgical management due to false-positive findings, no significant differences were found between CEDM and CEMRI (34.6% [9/26] vs. 44.0% [11/25], p=0.782). Conclusion: CEDM demonstrated a diagnostic performance comparable with CEMRI in depicting index cancers, secondary cancers, and occult cancer in the contralateral breast. CEDM demonstrated similar changes in surgical management compared with CEMRI.