• Title/Summary/Keyword: breakthrough curve

Search Result 125, Processing Time 0.033 seconds

Adsorption Characteristics of Acetone, Benzene, and Metylmercaptan in the Fixed Bed Reactor Packed with Activated Carbon Prepared from Waste Citrus Peel (폐감귤박으로 제조한 활성탄을 충전한 고정층 반응기에서 아세톤, 벤젠 및 메틸메르캅탄의 흡착특성)

  • Kam, Sang-Kyu;Kang, Kyung-Ho;Lee, Min-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.28-36
    • /
    • 2018
  • Adsorption experiments of three target gases such as acetone, benzene, and methyl mercaptan (MM) were carried in a continuous reactor using the activated carbon prepared from waste citrus peel. In a single gas system, the breakthrough time obtained from using the activated carbon (WCAC) prepared from waste citrus peel. In a single gas system, the breakthrough time obtained from the breakthrough curve decreased with increasing the inlet concentration and flow rate, but increased with respect to the aspect ratio (L/D). Adsorbed amounts of the target gases by WCAC increased as a function of the inlet concentration and aspect ratio. However, adsorbed amounts with the increase of the flow rate were different depending upon target gases. Results from the breakthrough time and adsorbed amount showed that the affinity for WCAC was the highest in benzene, followed by acetone and then MM. On the other hand, in the binary and ternary systems, the breakthrough curve showed a roll-up phenomenon where the adsorbate having a small affinity for WCAC was replaced with the adsorbate with a high affinity. The adsorption of acetone on WCAC was more strongly affected when mixing with the nonpolar benzene than that of using sulfur compound MM.

Fixed -bed Adsorption of Food-Related Phenolic Acids on Charocal in Single Solute System

  • Lee, Won-Young;Park, Yong-Hee
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.2
    • /
    • pp.123-127
    • /
    • 1998
  • Fixed-bed adsorption was adapted to separate phenolic acids from diluted phenolic solution. Break-through curve was obtained by nonlinear curve fitting method, and breakpoint, saturation time, and mass transfer coeffi-cient were calculated . Break point and saturation time were reached slower with $\rho$-coumaric acid than ferulic acid .The p-coumaric acid, having small molecular weight, is suposedly traveled longer pathway in characoal than ferulic acid. Fixed-bed adsorption iwht gallic acid having more hydroxyl functional group than other phenolic acids showed break point arrival and the largest saturation time. This fact means that there was bigger electrostatic affinity between gallic acid and charcoal than between other phenolic acids and charcoal.

  • PDF

Characterization of Adsorbents for the Simultaneous Solid-Phase Extraction of Trace $\beta$-Blockers from Biological Samples (생체시료로부터 미량 $\beta$-Blockers의 동시고상추출에 사용될 흡착제들의 특성)

  • Kim, Kyoung Rae;Kim, Do Jeong
    • Analytical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.375-381
    • /
    • 1993
  • The efficiencies of four different solid absorbents were evaluated for the simultaneous solid-phase extraction of six ${\beta}$-blockers from biological sample. Chromosorb 107 using methanol as the eluting solvent gave the highest solid-phase extraction yield. From the breakthrough studies of ${\beta}$-blockers, the excellent sorption and desorption properties of the Chromosorb 107 column were verified. The usefulness of Chromosorb 107/methanol was examined for the simultaneous solid-phase extraction of the ${\beta}$-blockers from serum in the concentration range of 2~8ppm.

  • PDF

Application of Weibull Distribution Function to Analysis of Breakthrough Curves from Push Pull Tracer Test

  • Hyun-Tae, Hwang;Lee, Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.217-220
    • /
    • 2003
  • In the case of the remediation studies, push pull test is a more time and cost effective mettled than multi-well tracer test. It also gives Just as much or more information than the traditionally used methods. But the data analysis for the hydraulic parameters, there have been some defections such as underestimation of dispersivity, requirement for effective porosity, and calculation of recovery of center of mass to estimate linear velocity. In this research, Weibull distribution function is proposed to estimate the center of mass of breakthrough curve for Push pull test. The hydraulic parameter estimation using Weibull function showed more exact values of center of mass than those of exponential regression for field test data.

  • PDF

Simultaneous Removal of Cd &Cr(VI) by Fe-loaded zeolite in Column System (컬럼실험을 통한 Fe-loaded zeolite의 Cd& Cr(VI) 동시제거 반응성 평가)

  • Lee A-Ra;Lee Seung-Hak;Park Jun-Beom
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.151-154
    • /
    • 2005
  • Laboratory column experiments for simultaneous removal of Cd and Cr(VI) are conducted using newly developed material, referred to as Fe-loaded zeolite, which has both reduction ability of iron and ion exchange ability of zeolite. Breakthrough curves were obtained from each column experiment, and described with advection-dispersion equation. Apparent parameters including $K_{app}\;and\;D_{app}$ were newly introduced for effectively describing the Cr(VI) breakthrough curve. $K_{app}$ decreased with increasing initial contaminant concentration and with decreasing flow rates. Whereas, $D_{app}$ were not significantly affected by initial contaminant concentration or flow rate.

  • PDF

Effect of Airborne Organic Vapor Concentration Levels on the Adsorption Capacity of Charcoal in the Cartridges of Air Purifying Respirators (공기 중 유기용제 농도수준이 방독마스크 정화통의 활성탄 흡착용량에 미치는 영향)

  • Park, Doo-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.1
    • /
    • pp.50-56
    • /
    • 2011
  • The adsorption capacity of charcoal is a function of the airborne concentration of the target chemical. To evaluate the adsorption capacity of charcoal packed in the cartridges of air purifying respirators, breakthrough tests were conducted with carbon tetrachloride for three commercial cartridges (3M models #7251, #6000 and AX) at 25, 50, 100, 250 and 500 ppm. Adsorption capacities were calculated using a mass transfer balance equation derived from the curve fitting to the breakthrough curves obtained experimentally. Carbon micropore volumes were estimated by iteration to fit the Dubinin/Radushkevich (D/R) adsorption isotherm. They were 0.6566, 0.5727 and 0.3087 g/cc for #7251, #6000 and the AX cartridge, respectively. Above 100 ppm (at high challenge concentrations), #7251 and #6000 showed higher adsorption capacities. However, as the challenge concentration decreased, the adsorption capacities of #7251 and #6000 sharply dropped. On the other hand, the adsorption capacity of the AX cartridge showed little change with the decrease of the challenge concentration. Thus, the AX showed a higher adsorption capacity than #7251 and #6000 at the 5-50 ppm level. It is concluded that service-life tests of cartridges and adsorption capacity tests of charcoal should be conducted at challenge concentration levels reflecting actual working environmental conditions. Alternatively, it is recommended to use the D/R adsorption isotherm to extrapolate adsorption capacity at low concentration levels from the high concentration levels at which breakthrough tests are conducted, at a minimum of two different concentration levels.

Development of an Sampling Tube for Organic Solvents and Study on the Adsorption Capacity of the Activated Charcoal (유기용제용 시료채취기 개발을 위한 활성탄 성능검정에 관한 연구)

  • Bai, Ya Soung;Park, Doo Young;Lim, Dai Soung;Park, Byung Moo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.8-18
    • /
    • 2005
  • Adsorption capacity for the charcoal were tasted in this study to verify the performance of them for the use of the sampling media in industrial hygiene field. Two set of experiments were conducted. The first experiment was to test performance of the tested charcoal tube that were assembled in the laboratory with the use of the GR grade charcoal. The other tests were investigate the adsorption capacity of the charcoal tested in this study and charcoals embedded in the commercial charcoal tubes. Known air concentration samples for benzene, toluene, and o-xylene were prepared by the dynamic chamber. 1. At low air concentration levels (0.1${\times}$TLV), there was no significant differences between the tested charcoal tubes and the SKC charcoal tubes. This implies that there is no defect with the adsorption capacity of the charcoal. 2. At high concentration with 60 minutes sampling, the breakthrough were found only in the tested charcoal while no breakthrough were shown in the SKC charcoal. 3. From the breakthrough tests for the charcoal, the micropore volume(Wo) were calculated by the curve fitting with the use of Dubinin/Radushkevich(D/R) adsorption isotherm equation. The calculated values were 0.687cc/g for SKC, 0.504cc/g for Sensidyne, and 0.419cc/g for the tested charcoal(Aldrich). 4. Adsorption capacities were obtained from the isotherm curves shown adsorption capacities at several levels of the challenge concentration. All range of the air concentration concerned in industrial hygiene, the SKC charcoal showed approximately two times of adsorption capacity compared to the tested charcoal.

Removal Characteristics of Lithium Ions by Fixed-bed Column Packed with Strong-Acid Cation Exchange Resin (강산성 양이온 교환수지를 충전한 고정층에서 리튬이온의 제거특성)

  • You, Hae-Na;Lee, Min-Gyu
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.166-170
    • /
    • 2014
  • The continuous experiments were carried out using fixed-bed column packed with strong-acid cation exchange resin for the removal of lithium ions from aqueous solution. The parameters such as bed height, flow rate and inlet concentration were investigated. Breakthrough time ($t_{0.05}$), saturation time ($t_{0.95}$), and total amount of lithium ion removed (mtotal) were obtained from the breakthrough curves. The results showed that $t_{0.05}$ and $t_{0.95}$ decreased with decreasing bed height, and decreased with increasing inlet concentration and flow rate. mtotal increased with increasing inlet concentration and bed height, but decreased with increasing flow rate. Thomas model and Yoon-Nelson model equations were applied to the experimental data, the results showed that the breakthrough data gave a good fit to Thomas model equation.

Breakthrough Curves and Elution Patterns of Heavy Metals in Sandy Clay Loam and Clay Soils (사질식양토와 식토토양에서의 중금속의 용탈과 파쇄곡선)

  • Chung, Doug-Young;Noh, Hyun-H.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • We investigated the mobilization of Cd, Pb, and Cr in two different soils in response to sorption capacities and competition for available sorption site while they moved under saturated water conditions. Two soil samples that were clay and sandy clay loam were collected within 20 cm from the upland surface. To do this, we used three different systems of heavy metal combinations such as single, binary, and ternary as solution phase. And then we observed the breakthrough curve (BTC) and elution as a function of pore volume by applying heavy metal solution and displacing K solution until these curves reached to maximum and minimum. The results showed that BTC and elution curves were not symmetric and it required more pore volumes with increasing species of heavy metals in solution phase, as well as longer tailings. Compared the areas over and under BTC and elution curve, relatively small amount of heavy metal was displaced by K even though there were differences in electronegativity among heavy metals. Conclusively, we assumed that heavy metals transport in soil could be influenced by soil physical nonequilibrium and chemical equilibrium in solution as far as there were more than two species of heavy metals existed.

Study on Adsorption Characteristics of Tharonil from Aqueous Solution by Activated Carbon Adsorption (활성탄에 의한 Tharonil의 흡착특성에 관한 연구)

  • 이종집;유용호
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.88-94
    • /
    • 2000
  • The adsorption characteristics of Tharonil on granular activated carbon were experimentally investigated in an adsorber and in a packed column. It was estabilished that the adsorption equilibrium of Tharonil on granular activated carbon was more successfully fitted by Freundlich isotherm equation than Langmuir isotherm equation in the concentration range from 1 to 1000 mg/1. Intraparticle diffusivities (pore and surface diffusivity) of Tharonil were estimated by the concentration-time curve and adsorption isotherm. The estimated values of pore diffusivity and surface diffusivity are $6.70{\times}10^{-6}$ and $2.0{\times}10^{-9}cm^2/s$, respectively. From comparison of intraparticle diffusivities, it was found that surface diffusion was the limiting step for adsorption rate. The break time and breakthrough curve predicted by constant pattern-linear driving force model were shown to agree with the experimental results.

  • PDF