• Title/Summary/Keyword: breakdown strength

Search Result 523, Processing Time 0.022 seconds

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.

V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages ($SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성)

  • Lee, Bok-Hui;Lee, Gyeong-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF

Study on the AC Interfacial Breakdown Properties in the Interface between toughened Epoxy and Silicone Rubber (Toughened 에폭시와 실리콘고무 계면의 교류 절연파괴 현상에 관한 연구)

  • 박우현;이기식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1079-1084
    • /
    • 2002
  • Because complex insulation method is used in EHV(extra high voltage) insulation systems, macro Interfaces between two different bulk materials which affect the stability of insulation system exist inevitably. Interface between toughened epoxy and silicone rubber was selected as a interface in EHV insulation systems and tested AC interfacial breakdown properties with variation of many conditions to influence on electrical Properties, such as interfacial pressure, roughness and oil. Specimen was designed to reduce the effect of charge transport from electrode in the process of breakdown and to have the tangential electrical potential with the direction of the interface between epoxy and silicone rubber by using FEM(finite elements method). It could control the interfacial pressure, roughness and viscosity of oil. From the result of this study, it was shown that the interfacial breakdown voltage is improved by increasing interfacial Pressure and oil. In particular, the dielectric strength saturates at certain interracial Pressure level. The decreasing ratio of the interfacial breakdown voltage in non-oiled specimen was increased by the temperature rising, while oiled specimen was not affected by temperature.

Electrical and Mechanical Strength Properties of Epoxy/Micro Silica and Alumina Composites for Power Equipment (전력기기용, 에폭시/마이크로 실리카 및 알루미나 복합제의 전기적·기계적 파괴 강도 특성)

  • Park, Joo-Eon;Park, Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.7
    • /
    • pp.496-501
    • /
    • 2018
  • In this study, we prepared 40, 45, 50, 55, 60, 65, and 70 wt% content composites filled in epoxy matrix for two micro silica and three micro alumina types for use as a GIS heavy electric machine. As a filler type of epoxy composite, micro silica composites showed excellent AC breakdown strength properties compared to micro alumina composites in the case of electrical properties of micro silica and alumina. The electrical breakdown properties of micro silica composites increased with increasing filler content, whereas those of micro alumina decreased with increasing filler content. In the case of mechanical properties, the micro silica composite showed improved tensile strength and flexural strength compared with the micro alumina composite. In addition, mechanical properties such as tensile strength and flexural strength of micro silica and alumina composites decreased with increasing filler content. This is probably because O-H groups are present on the surface of silica in the case of micro silica but are not present on the surface of alumina in the case of micro alumina.

A Study on the prevention of edge effect reducing dielectric strength (절연내력에 미치는 주변효과의 방지에 관한 연구)

  • Kwak, Hee-Ro;Shin, Hee-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.267-271
    • /
    • 1987
  • The test cell for preventing the edge effect reducing the intrinsic breakdown strength of polypropylene film and measuring the intrinsic breakdown strength of the film was developed. The new approach was to develope an electrode system with an edge region which is carefully graded over an extended distance. The new test arrangement employed a central circular electrode at high voltage and a set of nine concentric surrounding rings each controlled in potential by external grading resistors to be at decreasing potentials from that at the center in 10% increments. Two different size structures using the same basic principle were tried and were both found to be successful. The test electrodes were manufactured using standard printed circuit technology and were chosen to be copper on high dielectric constant GIO board.

  • PDF

Temperature dependance of Dielectric strength in Nano-composites (Nano-composites 절연파괴강도의 온도의존성)

  • Lee, Kang-Won;Lee, Hyuk-Jin;Kim, Jong-Hwan;Shin, Jong-Yeol;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.256-257
    • /
    • 2008
  • Recently, with the increase of demand of electricity, electric cable or electric transfer machine are rapidly developed and meet the demand with the extra high voltage and massive capacity, the dangers of electrical accident of insulator are increasing by the electric stress, insulation degradation and insulation breakdown in insulator. In this paper, it is investigated that the temperature dependance of dielectric strength in nano-composites. We obtained that breakdown voltage of 0.4 [wt%] specimens is higher than the other $SiO_2$ content.

  • PDF

Dielectric Strength According to Flow Pattern in EHV Power Cable Insulation (초고압 전력케이블 절연체의 Flow Pattern에 따른 절연성능 고찰)

  • LEE, Seung-Yop;KIM, Young-Ho;LEE, Sang-Jin;KIM, Dong-Wook;CHOI, Myung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1539-1541
    • /
    • 2000
  • Insulation layers in XLPE power cables may have some patterns generated in the manufacturing process. They are called 'flow patterns' and show flow history of molten polyethylene between inner and outer semiconducting layers. Flow patterns are even seen with naked human eyes and suspected to be inhomogeniety of insulation, weakening insulation performance. Investigated in this paper is electrical treeing resistance and ac breakdown strength according to flow patterns. Experiments of electrical treeing and ac breakdown strength by means of ramp tests were conducted using newly developed electrode system with point-to-plane structure and sphere-to-sphere structure, respectively. All results were analyzed with the application of statistics, showing little differences.

  • PDF

A study on the AC dielectric breakdown characteristics and mechanical characteristics of interpenetraing polymer network epoxy composites (상호침입망목 에폭시 복합재료의 교류절연파괴 특성 및 기계적 특성에 관한 연구)

  • 손인환;이덕진;김명호;김경환;김재환
    • Electrical & Electronic Materials
    • /
    • v.9 no.7
    • /
    • pp.702-707
    • /
    • 1996
  • In this paper, in order to improve the withstand voltage properties of epoxy resin, IPN(interpenetrating polymer network) method was introduced and the influence was investigated. The single network structure specimen(E series), simultaneous interpenetrating polymer network specimen(EM series) and pseudo interpenetrating polymer network(EMP series) specimen were manufactured. In order to understand the internal structure properties, scanning electron microscopy method was utilized, and glass transition temperature was measured. Also, AC voltage dielectric breakdown strength, tensile strength and impact strength were measured to investigate the influence upon electrical and mechanical properties. As a result, it was confirmed that simultaneous interpenetrating polymer network specimen was the most execellent.

  • PDF

Electrical and Physical Properties of XLPE/EnBA Blends (XLPE/EnBA 블렌드의 전기 및 물리적 성질)

  • 서광석;오우정;이승형
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1060-1069
    • /
    • 1998
  • Electrical properties such as space charge accumulation and water tree length and physical properties such as tensile strength, elongation and degree of crosslinked polyethylene (XLPE)/ethylene n-butyl acrylate copolymer (EnBA) blends were investigated. It was found that electrical properties such as water tree length grown at a specific condition and AC breakdown strength are improved by blending the XLPE with EnBA. The EnBA having higher nBA content showed the better electrical properties in XLPE/EnBA blends. A further improvement of these properties was achieved when a small amount of crosslinking coagent was used in the preparation of XLPE/EnBA blends.

  • PDF

A Study on Thermal, Mechanical and Electrical Properties as Silane Treated Epoxy/MICA Composites (실란처리된 Epoxy/MICA 콤포지트의 열적, 기계적 전기적 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.213-218
    • /
    • 2013
  • In this study, epoxy/mica composite was prepared by mixing with mechanical stirrer together with homogenizer, and the effect of amino-type silane coupling agent was also studied. To reduce the viscosity without any decrement of other properties, 1,4-Butanediol diglycidyl ether (1,4-BDGE) as an aliphatic epoxy reactive diluent was introduced to the epoxy/mica composite in order to use as vanish for high voltage motor and generator stator winding. It was confirmed by scanning electron microscopy (SEM) observation that interfacial characteristics between organic epoxy and inorganic mica was modified by coupling agent treatment so that glass transition temperature increased, and tensile strength and electrical breakdown strength increased. The properties were estimated by Weibull statistical analysis and the ac electrical breakdown strength was 20.2% modified by treating silane coupling agent.