• Title/Summary/Keyword: breakdown strength

Search Result 523, Processing Time 0.025 seconds

A study on the dielectric breakdown properties of two and three interpenetrating polymer network epoxy composites (2,3 성분 상호침입망목 에폭시 복합재료의 절연 파괴 특성에 관한 연구)

  • 김명호;김경환;손인환;이덕진;장경욱;김재환
    • Electrical & Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.364-371
    • /
    • 1996
  • In this study, in order to investigate the applicability of IPN structure to epoxy resin which has been widely used as electrical and electronic insulating materials, DC dielectric breakdown properties and morphology were compared and analyzed according to variation of network structure, using the single network structure specimen formed of epoxy resin alone, interpenetrating polymer network specimen formed of epoxy resin/methacrylic acid resin, and interpenetrating polymer network specimen formed of epoxy resin/methacrylic acid resin/polyurethane resin. As results of the measunnent of DC dielectric breakdown strength at 50[.deg. C] and 130[>$^{\circ}C$], IPN specimen formed of epoxn, resin 100[phr] and methacrylic acid resin 35[phr] was the most excellent, and which corresponded to the SEM phenomena. The effect of IPN was more remarkable at high temperature region than at low temperature region. It is supposed that the defect of epoxy resin, dielectric breakdown strength is lowered remarkably at high temperature region, be complemented according to introducing IPN method.

  • PDF

A Study on the Dielectric Breakdown Strength Characteristics of Epoxy-$SiO_2$ Compound Material for Electric Installation (전기설비용 에폭시-$SiO_2$ 복합재료의 절연파괴 특성에 관한 연구)

  • 김재환;박창옥
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.2
    • /
    • pp.77-83
    • /
    • 1991
  • In this study the investigation were carried out on short-term breakdown characteristics of the compound material dependent on change of filler quantity, ambient temperature(room temperature~[$190[^{\circ}C$]) and kinds of voltage sources for the compound materials of Bisphenol- A epoxy resins filled with $SiO_2$ particles. As the results, obtained the dielectric breakdown strength generally decrease as increasing the quantity of filler and the distance, spacing of each's particles, decrease as increasing the quantity of filler, when the distance is less than [$7.5\mu\textrm{m}$], dielectric breakdown strength is nearly constant. In the case on AC voltage dielectric strength of filled epoxy resins is stronger than nonfilled epoxy resins on temperature region more than $130[^{\circ}C$].

  • PDF

Electrical Properties and Temperature Effects of PET Films with Interface Layers

  • Dong-Shick kim;Lee, Kwan-Woo;Park, Dae-Hee;Lee, Jong-Bok;Seun Hwangbo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.4
    • /
    • pp.25-29
    • /
    • 2000
  • In this paper, PET(Ployethylene Terephthalate) films with semiconducting and interface layers were investigated, The electrical properties, such as volume resistivity, tan$\delta$(dissipation factor) and breakdown strength at various temperatures were measured. Thermal analysis of PET and semiconducting films were measured and compared by differential scanning calorimeter(DSC) of each film. It is found that the volume resistivity of films(dependence on semiconducting interface layers)and electrical properties of PET films are changed ,Breakdown strength and dissipation factor of PET films with semiconducting layer (PET/S/PET) are decreased more greatly than PET and PET/PET films, due to the increase of charge density of charges at two contacted interfaces between PET and semiconductor, The dissipation factor of each films in increased with temperature,. For PET/S/PET film, is depended on temperature more than PET of PET/PET. However, the breakdown strength is increased up to 85$\^{C}$ and then decreased over 100$\^{C}$The electrical properties of PET films with semiconducting/interface layer are worse than without it It is due to a result of temperature dependency, which deeply affects thermal resistance property of PET film more than semiconducting/interface layers.

  • PDF

Evaluation of Electrical Degradation in Epoxy Composites by DC Dielectric Breakdown Properties (DC 절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 평가)

  • 임중관;박용필
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.779-783
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. As a result, first of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. And the breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised, the electric field is concentrated, and the acceleration of electron and the growth of electron avalanche are early accomplished. In the case of filled specimens with treating silane, the breakdown strength become much higher since this suggests that silane coupling agent improves interfacial combination and relaxs electric field concentration. Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1%, the applied field value needed to be under 21.5MVcm.

  • PDF

The Effect of Butt gaps on Dielectric Strength of Taped Insulation in Superconducting Cable

  • Andreev, Alexander-M;Kim, Soo-Yeon;Lee, In-Ho;Kim, Do-Woon;Shin, Doo-Sung
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.128-132
    • /
    • 2003
  • This paper discusses several electrical properties of tape-type insulation impregnated with liquid nitrogen ($LN_2$) in superconducting cable. Synthetic polypropylene laminated paper has been tested for its short-term breakdown strength and partial discharge(PD) characteristics under AC voltage. furthermore, the effect of winding parameter on breakdown strength, PD incepti on and extinction electrical stress with different test samples are discussed.

Electrical and Mechanical Properties of Epoxy/Micro-sized Alumina Composite and the Effect of Nano-sized Alumina on Those Properties

  • Park, Jae-Jun;Shin, Seong-Sik;Yoon, Chan-Young;Lee, Jae-Young;Park, Joo-Eon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.260-263
    • /
    • 2015
  • Epoxy/micro-sized alumina composite was prepared and the effects of alumina content on the electrical and mechanical properties were investigated in order to develop an insulation material for gas insulated switchgear (GIS). Nano-sized alumina (average particle size: 30 μm) was also incorporated into the epoxy/micro-sized alumina composite. An electrical insulation breakdown strength test was carried out in sphere-sphere electrodes and the data were estimated by Weibull statistical analysis. Tensile strength was measured at a crosshead speed of 10 mm/min using a universal testing machine. Alumina content was varied from 0 wt% to 70 wt%.). As micro-sized alumina content increased, insulation breakdown strength increased until 40 wt% alumina content and decreased after that content. The tensile strength of a neat epoxy system was 82.2 MPa and that value for 60 wt% alumina content was 91.8 MPa, which was 111.7% higher than inthe neat epoxy system. The insulation breakdown strength of micro-sized alumina (60 wt%)/nano-sized alumina (1 phr) glycerol diglycidyl ether (GDE) (1 phr) composite was 54.2 MPa, which was 116% higher than the strength of the system without nano-sized alumina.

Electrical and Mechanical Properties of Epoxy/Heterogeneous Inorganic Composites Materials for the Application of Electric Power GIS Appliances (친환경 GIS용 전력기기의 적용을 위한 에폭시 이종무기물 복합재료의 전기적, 기계적 특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1633-1640
    • /
    • 2018
  • Epoxy resin is a polar thermosetting polymer that is widely employed in different branches of industry and everyday life, due to their stable physical and chemical properties. Of all the polymer materials currently being used in the electrical insulation industry, epoxy resin is the most widely used kind, chosen as the base polymer material in the present study. Composites were prepared according to the mixing ratio (MS: MA, 1: 9, 3: 7, 5: 5, 7: 3, 9: 1)of mixture for Heterogeneous Minerals(Micro Silica:MS, Micro Alumina:MA) (MS+MA). We have investigated for AC electrical insulation breakdown characteristics and the dielectric properties (permittivity, dielectric loss, and conductivity) with frequency changes. The electrical AC insulation breakdown performance was improved with the increase of the mixing ratio of MS according to heterogeneous mineral material mixture(MS+MA). As Dielectric properties, the dielectric constant and dielectric loss increased with decreasing frequency and decreased with increasing MS content ratio of heterogeneous mineral mixture. Tensile strength and flexural strength according to the mixing ratio (MS + MA) of epoxy / heterogeneous mineral mixture were studied by mechanical properties. The performance of mechanical tensile and flexural strength was significantly improved as the fill contents ratio of MS increased.

Study on the Breakdown Performance of Synthetic Polypropylene Laminated Paper for Application of a HTS Cable (고온초전도 케이블의 응용을 위한 PPLP의 절연파괴 특성연구)

  • Kwag, Dong-Soon;Kim, Young-Seok;Kim, Hae-Jong;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.65-68
    • /
    • 2003
  • In this paper, we researched breakdown characteristics of paper/liquid nitrogen composite insulation system for application of a high temperature superconducting cable. And, we have studied the AC breakdown performance of paper/ice composite insulating system immersed in liquid nitrogen. The electric strength in this paper/ice composite system is higher than that of paper/liquid nitrogen system. Furthermore this system shows a self-healing type breakdown behavior. Among the many kinds of liquid to be immersed and frozen to the ice, deionized water gives the highest electric breakdown strength. The paper/ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

SLI, AC Breakdown Voltage Characteristics of $SF_6/CF_4$ Mixtures Gas in Nonuniform Field (불평등전계에서 $SF_6/CF_4$ 혼합 가스의 SLI, AC 절연내력 특성)

  • Hwang, Cheong-Ho;Sung, Heo-Gyung;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.245-251
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field was performed. The experiments were carried out under AC voltage and standard lightning impulse(SLI) voltage. Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltages and standard lighting impulse voltage was applied in a needle-plane. The needle-plane electrode whose gap distance was 3 mm were used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field may be influenced by defects like needle-shaped protrusions. In case of slowly rising SLI voltage and AC voltage it is enhanced by corona-stabilization. This phenomena caused by the ion drift during streamer development and the resulting space-charge is investigated. In non-uniform field under negative SLI voltage the breakdown voltage was increase linearly but under positive SLI voltage the breakdown voltage increase non-linearly. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at AC voltage. $SF_6/CF_4$ mixture has good dielectric strength and arc-extinguishing properties than pure SF6. This paper presents experimental results on breakdown characteristics for various mixtures of $SF_6/CF_4$ at practical pressures. We could make an environment friendly gas insulation material with maintaining dielectric strength by combing $SF_6\;and\;CF_4$ which generates a lower lever of the global warming effect.

DC Dielectric Breakdown Properties of Epoxy Composites with Variation of Additives and Curing Conditions (첨가제 및 경화조건 변화에 따른 에폭시 복합체의 DC 절연파괴특성에 관한 연구)

  • Chug, Kyu-Hee;CHoi, Woon-Shik;Wang, Jong-Bae;Kim, Hong-Chul;Lee, Joon-Ung
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.883-885
    • /
    • 1992
  • DC dielectric breakdown properties of epoxy composites with various additives rates and curing conditions were investigated at the temperature range from 20[$^{\circ}C$] to 180[$^{\circ}C$]. At low temperature an improvement of the characteristics is observed due to curing agents. The additions of filter is lower the temperature dependences of the breakdown strength. Samples treated with silan have a higher breakdown strength than non-treating filled samples.

  • PDF