• 제목/요약/키워드: box unit system

검색결과 86건 처리시간 0.023초

I형 단면과 BOX형 단면을 갖는 프리캐스트 분절 PSC 거더의 실험적 연구 (An Experimental Study on the Precast Segmented PSC Girder with I-Shape and Box-Shape Cross-Section)

  • 김선희;이승후;박준석;천진욱;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.8-16
    • /
    • 2015
  • Prestressed concrete (PSC) is a method in which prestressed tendon is placed inside and/or outside the reinforced concrete member and the compressive force applied to the concrete in advance to enhance the engineering properties of concrete member which is weak under tension. In this paper we suggested the precast PSC girder assembled with segments of portable size and weight at the factory. The segments of precast PSC girder will be delivered and assembled as a unit of PSC girder at the site. Consequently, we suggested new-type of precast segmented PSC girder with different shapes of segment cross-section (i.e., I-shape, Box-shape). To mitigate the problems associated with the field splice between the segments of precast PSC girder anchor system is attached near the neutral axis of the girder and relatively uniform compression throughout the girder cross-section is applied. Prior to the experimental investigation, analytical investigation on the structural behavior of precast PSC girder was performed and the serviceability (deflection) and safety (strength) of the girder were confirmed. In addition, 4-point bending test on the girder was conducted to investigate the structural performance under bending. From the experimental investigation, it was found that the precast PSC girder spliced with 3 and 5 segments has sufficient in serviceability and safety conditions and it was also observed that the point where the segments spliced has no defects and the girder behaves as a unit.

Structural Characteristics of Two Wheat Histone H2A Genes Encoding Distinct Types of Variants and Functional Differences in Their Promoter Activity

  • Huh, Gyung-Hye;Iwabuchi, Masaki
    • 한국식물학회:학술대회논문집
    • /
    • 한국식물학회 1996년도 제10회 식물생명공학심포지움 고등식물 발생생물학의 최근 진보
    • /
    • pp.26-38
    • /
    • 1996
  • To investigate the regulation of plant histone H2A gene expression, we isolated two H2A genes (TH254 and TH274) from wheat, which encode different types of variants. Both genes had an intron in the coding region. In the promoters, some characteristics sequences, such as Oct and Nona motifs, which are conserved among plant histone genes were also found, and they were located in a short region (about 120 bp) upstream from the putative TATA box. Analyses of promoter activity with H2A-GUS fusion genes in the transient system using tobacco protoplasts revealed novel types of positive cis-acting sequences in the TH254 promoter: a direct repeat of a 13-bp sequence (AGTTACATTATTG) and a stretch composed of an AT-rich sequence (ATATAGAAAATTAAAA) and a G-box (CACGTG). A quantitative S1 assay of the mRNA amounts from the TH254/GUS and TH274/GUG chimeric genes in stably transformed and cell cycle-synchronized tobacco cell lines showed that the promoters of both genes contained at least one cis-acting element responsible for S phase-specific expression. Histochemical analysis of transgenic tobacco plants carrying the chimeric genes showed that the promoters of the two H2A genes were both active in developing seedlings and flower organs but regulated in different manner.

  • PDF

랙크 내 파렛트단위 적재물품의 화재특성에 관한 연구 (A Study on the Fire Characteristics of Palletized Unit-Load Commodities on Racks)

  • 조규환;여인환
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.23-30
    • /
    • 2016
  • 현재, 국내 랙크식 창고의 소화설비들은 연면적 및 층수만을 고려하는 평면적인 입장에서의 사양설계로 이루어지고 있다. 하지만 수직적인 구조를 갖는 랙크식 창고는 평면적인 소화설비뿐만 아니라 입면적인 측면도 함께 고려되어져야 하며, 상황에 따른 적절한 성능설계를 지향하기 위해서는 랙크 내 적재되는 물품의 화재하중 산정이 우선시되어야 한다. 이에 본 연구에서는 국내 현장조사 결과와 국외 적재물품 위험도등급 등을 함께 고려하여 구성된 표준 파렛트단위 적재물품(파렛트 +박스단위 적재물품 +비닐포장재)의 화재특성을 분석하였다. 그 결과로 화재하중 산정을 위한 열방출율 및 화재감지기 등의 소화설비를 위한 환경조건인 연기발생률을 도출하였다.

DMSO 첨가에 따른 리튬이차전지용 복합필름의 전기적 특성 (The Electrical Characteristic of Composite Film for Lithium Secondary Battery by adding DMSO)

  • 박수길;김종진;이창진;김상욱;김현후;임기조;이주성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.269-272
    • /
    • 1997
  • The Lithium ion secondary battery has been developed for high energy density of portable electrical device and electronics. Among the many conductive polymer materials, the positive active film for Li polymer battery system was synthesized successfully from polyphenylene diamine(PPD) by chemical polymerization in our lab. And PPD-DMcT(2, 5-dimercapto-1, 3, 4-thi-adiazole) composite flim conductive material, at high temperature was also prerared with the addition of dimethylsulfoxide(DMSO). The surface morphology and thermal stability of prepared composite flim was carried out by using SEM and TGA, respectively. Electrochemical and electrical conductivity of composite flim were also discussed by cyclic voltammetry and four-probe method in dry box(<27pm). And the electrode reaction mechanism was detected and analyzed from the half cell unit battery system.

  • PDF

CWS(Continuous Wall System)II 공법의 특성 및 적용성 (Characteristics and Applicability of CWS(Continuous Wall System)II Method)

  • 임인식;이정배;김재동;이재호;우성우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.43-47
    • /
    • 2008
  • CWSII method was developed to overcome the problems of frequent occurrence in the application of existing downward construction methods, especially in the case of using slurry wall instead of SCW or CIP as a retaining wall. By the improvements in connecting steel beams with the wall, CWSII method is able to ensure the settlement of a steel beam and the diaphragm effect of a slab while reducing the degree of difficulty and the term of works and the cost of construction. As the desired results, CWS method can be applied as a practical downward construction method regardless of the type of retaining wall. In this paper, besides the concept and features of CWSII method, it can be seen that the method can provide reliable and economical performances by comparing with existing methods.

  • PDF

Cloning and Characterization of Porcine Uroplakin II Gene

  • D. N. Kwon;H. K. Shin;C. K. Hwang;D. W. Ok;Kim, J. H.
    • 한국동물번식학회:학술대회논문집
    • /
    • 한국동물번식학회 2001년도 춘계학술발표대회
    • /
    • pp.19-19
    • /
    • 2001
  • Mammalian urothelium undergoes unique membrane specialization by making the asymmetric unit membrane (AUM) that is covered with the apical cell surface during terminal differentiation. The AUM contains several major integral membrane proteins including uroplakin Ia, Ib, II and III. The genes for uroplakins have been cloned from humans and mice, but not from porcine. In this study, we report the cloning of the UPII genomic DNA, which codes for the full length open reading frame for the uroplakin II protein. The deduced amino acid sequence encodes of a hydrophobic NH$_2$-terminal peptide, a prosequence, and a mature protein. The prosequence contains three potential N-glycosylation sites and a RGRR cleavage site that may be involved in uroplakin II processing and maturation. Northern and immunohistochemistry analyses showed that the porcine UPII gene is only expressed in urothelium and that the protein was specifically localized in urothelial superficial cells. A 2kb of upstream in the promoter sequence contains multiple transcription factor binding sites, including GC-box, SPI, AP2, and GATA-box sites, but not for TATA or CAAT-box sequences. Comparison of the porcine UPII promoter sequence with that of the murine by MEME system presented two conserved motifs, suggesting a cis-acting regulatory role for the conserved sequences. Sequence homology between two species in motif A and B was 79% and 80% respectively, although their relative locations were different. During the gestation, mouse bladder at estrus stages and day 10 after parturition showed higher UPII expression, while showed lower expression at peri-implantation stage. Taken together, our results showed that the porcine UPII gene was expressed highly and specifically in the bladder urothelium and that steroid hormones for implantation changed the expression of UPII in the bladder, although the biological significance of UPII remains to be not determined.

  • PDF

닭고기 품질등급제에 대한 도계장 관리자 설문 조사 (Survey of Manager's Perception of Slaughter House for Poultry Grading)

  • 채현석;유영모;안종남;함준상;정석근;이종문;최양일
    • 한국가금학회지
    • /
    • 제32권2호
    • /
    • pp.107-112
    • /
    • 2005
  • 본 연구는 닭고기의 품질 등급을 설정하기 위한 기초 자료로 이용하기 위하여 시중 도계장을 대, 중, 소로 구분하여 생산 관리 책임자들을 대상으로 닭고기 등급제 적용에 따른 도계장 및 유통업소 및 판매장 조사를 통하여 등급 판정 방법, 표본 수 선발 방법 등을 설정하여 설문지에 의한 방문 조사를 실시한 결과는 다음과 같았다. 도계장 설문 조사에서 등급제 적용시 적용 단위는 대부분의 도계장에서 농가단위 보다는 롯트 단위를 선호하였다. 닭고기 등급제 조사방법은 대부분의 도계장에서 전수 조사보다는 샘플 조사를 선호하였다. 닭고기 등급제 시행 초기에는 도계장에서 요청한 물량에 대해서만 등급 판정을 실시하는 것을 선호하였다. 통닭뿐만 아니라 부분육에 대해서도 등급제를 적용해야 된다는 의견이 많았다. 닭고기 등급제 적용시의 중량의 범위는 대규모 도계장에서는 $8\~12$호에 대해서 등급 판정을 선호하였다. 도계조건에서 실신 시 전압은 대규모의 경우 81V이상의 전압을 주로 사용하였고, 냉각조는 대규모 도계장 일부를 제외하고는 침수식을 사용하였다. 대규모 도계장에서는 닭고기 출하 시 개체 및 박스 포장을 같이 사용하고 있었으나 소규모 도계장은 박스 포장만 사용하였다.

거주자 참여형 공동주거의 평면계획에 적용된 가변성의 특성 - 유럽의 거주자 참여형 다층 공동주거를 중심으로 - (The Characteristics of Flexibility applied to Unit Plan of Housing by Residents Participation - focusing on European Multi-story Housing applying Residents Participation -)

  • 김현주
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.113-123
    • /
    • 2018
  • First of all, the multi-story Housing applying resident's participation in europe was classified by the menu selection method, the two-step supply method and the cooperative method. And then I analyzed flexible unit plan of cases for deriving the planning methode and the characteristics of flexibility. First, I analyzed the area and form of the unit plan, structure and Installation, fixed and variable elements to derive the planning method. The area of units are distributed from a minimum of $35m^2$ to a maximum of $150m^2$, and many of the unit planes have a narrow front and a deep depth. The structure is a long-span wall-structure or a skeleton structure, and is designed without any columns and bearing walls in the interior space for flexibility in spatial composition. The vertical shafts are located in the center of the unit in a box-form or in the corner at the unit dividing wall for free placement of interior wall. Fixed elements are framework and facility systems. Most of the future residents in the two-steps supply method and the cooperative method were able to freely design the internal space within the zoning concept proposed by the architect and change the location of the facade element within module system proposed by the architect. Second, the characteristics of the flexibility applied to the unit plan were divided in integrated flexibility, functional flexibility, construction flexibility, and supply flexibility. The integrated flexibility enables residents to give the variable space combination based on the complex structure of the inner space for providing various living experiences. Regarding functional flexibility, the three-dimensional spatial structure with neutral space has multi-functionality according to the needs of residents and easily accepts mixing of hybrid programs such as work and residence. Constructive flexibility allows residents to create identity by freely planning interior space and changing the size or location of facade components in a determined system of architects. Finally, various types of size and space composition are proposed and realized in the whole building applying menu selection method, so that flexibility in the offer can accommodate and integrate various types of living.

원유펌프시스템의 열전달해석 및 냉각설계 (Heat Transfer Analysis and Cooling Design for Crude Oil Pump System)

  • 김완기;이준엽;권중록;김해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2017-2022
    • /
    • 2008
  • The crude oil pump system is the equipment for transporting crude oil and it consists of 3 major components, a motor and an impeller which discharge underground crude oil, a pipestack that transmits the cooling oil and power, and a cooling oil unit & junction box that provides cooling oil and electric power. When considering the system characteristics that it has to be installed at a depth of deeper than 100 m, a design technology for the efficient control of the heat occurring at a conductor and motor is necessary and it is the essential factor for ensuring system durability. In this paper, therefore, cooling oil flow has been calculated to satisfy the limit value of the system temperature by analyzing heat flow considering the related losses such as loss of conductor, contact resistor loss at the conductor connection, and operation loss of motor. And the operation temperature has been set up based on the temperature of crude oil and the heat of motor and conductor. Also, a design for cooling of crude oil pump system has been proposed by calculating the operation pressure loss and selecting the capacity of a cooling oil pump and a heat exchanger.

  • PDF

IC 센서를 이용한 고속철도차량 구동장치의 무선 온도 모니터링 시스템 (Wireless Temperature Monitoring of Driving Gear Unit in High Speed Train Using IC Sensor)

  • 권석진;서정원;이동형;황지성
    • 한국정밀공학회지
    • /
    • 제30권7호
    • /
    • pp.673-678
    • /
    • 2013
  • Driving gear units can be affected by various problems, including those associated with external or internal defects in the bearing, problems with the lubricant oil, high-loading of the railway, and frequent impacts generated by rail joints. Temperature monitoring is a basic method in diagnosing abnormal conditions in the reduction gear and other components. This paper describes a new wireless monitoring system for the temperature diagnosis of abnormal conditions of the reduction gear. Integrated circuit (IC)-type temperature sensors were installed in the reduction gear box of a high-speed railway car. The temperature data from the reduction gear were acquired and analyzed in situ during high-speed rail operation. Analysis of these data was used to alert the driver and/or maintenance personnel when problems occurred.