To assess possible risks from the consumption of drinking water from various sources, a survey of the microbiological quality of tap water, commercial bottled drinking water which is exploited from natural mineral water, and natural spring water was conducted. A total of 4 different brands of commercial bottled drinking water, and 4 types of spring water from different sources, and tap water from 4 private houses were tested for four index microorganisms, and the microbial quality changes of the water during the storage at room temperature or refrigerated temperature for 7 days. Aerobic plate counts of all of the initial water samples were still within 100 CFU/ml (drinking water standard of Korea). Total coliforms, fecal coliforms, and E. coli were not detected in all of the water samples at initial. However, aerobic plate counts of three types of spring water and three types of bottled drinking water stored at room temperature showed higher levels than the standards in 5 days. Total coliforms were detected in three types of spring water after one day's storage at room temperature, and in one type of bottled drinking water after 5 days' storage. These results indicate that some of the spring water surveyed are not safe to drink, and the spring water and bottled drinking water after opening the lid should not be stored at room temperature, if they are used for drinking.
Objectives: Although water is essential for life and can supply essential minerals, studies that evaluate calcium intake through drinking water are limited. The aim of this study was to assess calcium contents of natural mineral water (NMW) and its possible contribution to calcium intake in healthy adults. Methods: This study examined water consumption in 640 Korean adults with self-selected diet, analyzed the calcium content of 10 different brands of bottled NMWs sold in Korea, and assessed the amount of calcium intake from drinking water and its daily contribution to the recommended nutrient intake (RNI) of calcium. Results: Mean calcium content in 10 bottled NMWs was 20.9 mg/l. Daily water intakes from food composition database and calculated using energy intake based on 0.53 ml/kcal were 957.2 ml and 1109.8 ml for men and 848.3 ml and 951.6 ml for women, respectively, with a significant difference by gender (p<0.001). Daily drinking water intake was significantly higher among men than women (1203.9 ml vs. 1004.3 ml, respectively, p<0.001). Daily calcium intakes from foods were 564.0 mg for men and 534.2 mg for women. Daily possible calcium intakes from drinking bottled water were 25.2 mg for men and 21.0 mg for women (p<0.001). The contribution of daily calcium intake from drinking bottled water to RNI of calcium was 3.3% for men and 2.9% for women without significant difference. Conclusions: One half of the daily total water intake was consumed as drinking water, and possible calcium intake through drinking water was about 3% of RNI.
The demand for bottled water in South Korea is steadily increasing, but there are challenges regarding water sources and violations of water quality standards. Consumers struggle to identify products that do not meet these standards, highlighting the need for improved water management. This study aims to investigate the use of flow cytometry to identify microbial behavior in bottled water. Twelve different bottled water brands were selected for this study. A novel non-culture-based analysis method called total cell count via flow cytometry was utilized, which is not commonly used to assess drinking water quality. This method was compared to conventional culture-based methods for heterotrophic plate count and E. coli experiments, in order to introduce new indicators for hygiene management. Adenosine triphosphate analysis was also conducted to assess cell activity, and total organic carbon was measured to determine the presence of organic matter. The total cell counts varied among the different bottled water brands. The adenosine triphosphate levels ranged from 37.1ng/L to 221.7ng/L, while the total organic carbon ranged from 0.4 to 0.6 mg/L. Furthermore, E. coli was not detected in any of the bottled waters, and with the exception of two cases, the levels of heterotrophic bacteria did not exceed the drinking water standard of 100 CFU/mL. This study demonstrated a correlation between total cell count and heterotrophic plate count, suggesting that non-culture-based analysis could be valuable in promptly assessing microbial contamination, in contrast to the conventional methods that require approximately 48 hours for incubation.
Objective: This study was conducted to investigate changes in microbiological quality according to various storage conditions in the drinking process of bottled mineral water. Methods: Heterotrophic plate counts ($21^{\circ}C$ and $36^{\circ}C$) and pathogenic indicators (total coliforms, fecal Streptococcus, Pseudomonas aeruginosa, Clostridium perfringens, Salmonella, and Shigella) were analyzed in commercial bottled mineral water stored under different conditions ($4^{\circ}C$, $20-25^{\circ}C$, $36^{\circ}C$) after injecting saliva. The heterotrophic plate counts were analyzed twice per day for the first week and once per day for the three weeks after. Pathogenic indicators were analyzed at the beginning and end (initial and final). Results: The results of the microbiological quality of the bottled mineral water in contact with saliva showed that heterotrophic plate counts ($21^{\circ}C$) had a tendency to be sustained or decrease slightly after 10 days. Heterotrophic plate counts ($36^{\circ}C$) had a high population in the initial samples and gradually decreased at $4^{\circ}C$ storage, but it remained constantly high in storage at $20-25^{\circ}C$ and $36^{\circ}C$. In the general drinking condition, the population was slightly higher than the control, but the overall trend was similar. Conclusions: As a result of the microbiological quality of mineral bottled water in contact with saliva during the process of drinking, heterotrophic plate counts ($21^{\circ}C$ and $36^{\circ}C$) showed a high population compared to the control, which was only opened and not in contact with saliva. In some samples, pathogenic indicators were also detected. Therefore, it is desirable to consume bottled mineral water as soon as possible after opening.
Several drinking water treatment plants (DWTPs) produce the bottled tap waters (BTWs) as pilot production and provide them for noncommercial use. In 2008, acetaldehyde and chloral hydrate were detected in some BTWs and the public worry over the safety of the water. In this study, the BTWs produced from 7 DWTPs were tested for 13 chemicals including disinfection byproducts (DBPs). The level of four trihalomethanes (THMs) were increased up to 15 days. The average concentration of them was 0.0075 mg/L at the time of bottling and it was increased to 0.0214 mg/L after 15 days. The average acetaldehyde concentration was 0.0406 mg/L at the time of bottling but it was went up to 0.2251 mg/L after 11 days and then decreased. Although the initial concentrations of DBPs were below the drinking water standard, we also traced them at different storage conditions. Temperature affected the formations of THMs and acetaldehyde concentrations significantly. While the average concentration of THMs ranged from 0.0113 to 0.0182 mg/L at $25^{\circ}C$, it was increased to 0.0132 ~ 0.0256 mg/L at $50^{\circ}C$. In case of acetaldehyde, concentration ranged from 0.0901 to 0.2251 mg/L at $25^{\circ}C$, it was increased to 0.3394 ~ 1.0591 mg/L at $50^{\circ}C$. Throughout the tests with 7 BTWs samples, none of the chemicals was exceeded the drinking water standard of Korea. Therefore, it is recommended to avoid the exposure of BTWs to sunlight or high temperature during distribution and storage.
먹는 물 중 bromate의 국내 외 시험방법에 대한 분석 조건을 비교하여 최적 시험조건을 확인하고 ion chromatograph-suppressed conductivity detector (IC-CD)를 사용하여 먹는 샘물 중 bromate 함량을 분석하였다. 시료 전처리를 위해 먹는 샘물 20 mL를 온가드 Ba-, Ag-, H-카트리지 순서대로 통과시키고 마지막에 $0.2\;{\mu}m$ 맴브레인 필터로 여과 하였다. 여과한 시료는 IC-CD에 주입하였으며, 시료 중 bromate는 10~50 mM의 KOH 이동상 및 수산화이온용액 이동상에 적합한 가드 및 분석용 컬럼인 AG 19 및 AS 19에 의해 분리하였다. Bromate의 검정 곡선은 $0.5\sim40\;{\mu}g/L$의 농도 범위에서 $r^2$값이 0.9998로 좋은 직선성을 보였으며, 방법검출한계(MDL) 및 정량한계(LOQ)는 각각 0.1, $0.5\;{\mu}g/L$이었다. 2009년 9월 이후 유통 중인 먹는 샘물 157 개 시료를 분석한 결과, 33 개 시료에서 bromate가 검출되었으며, 검출된 시료의 평균농도는 $2.4\;{\mu}g/L$ 이었다. 측정 농도 범위는 $0.5\sim6.5\;{\mu}g/L$로 모두 국내 먹는샘물 수질기준인 $10\;{\mu}g/L$ 이내였다.
In recent years, the sales of bottled spring water (BSW) have been drastically increasing in Korea and other countries, which accompanied great interests in conservation and reclamation of natural mineral water (NMW). In this study, management and research activities on NMW in Europe, USA, and Codex Alimentarius were reviewed. In each region, NMW is regulated with its own quality standards that differ from ordinary drinking water, and management actions are strictly implemented to protect water resources and to secure quality of NMW. Many studies on NMW were carried out for monitoring inorganic constituents including major and trace elements in national levels for bottled NMW, groundwater, and tap water in other countries. In Korea, NMW became commercialized in 1995 when BSW was legally approved as a drinking water. To further promote utilization of various types of NMW in Korea, regulations and policies for NMW need to be revised in accordance with international NMW management trends. Further, studies of NMW that compile a comprehensive set of physical and chemical parameters of NMW are also needed to properly understand occurrences, hydrogeological and geochemical processes of NMW, as well as to evaluate its potential use as a natural resource.
Due to the growing demand for bottled mineral waters, a study was undertaken to determine the quality of the twenty six brands of domestic and imported drinking waters. The quality of water was evaluated by analyzing the twenty four elements including minerals, essential and/or toxic trace elements, and the analytical items to affect the taste of water. The contribution of drinking water to the mineral nutrition of human was calculated in order to investigate the health effect of drinking water. The taste of water was evaluated in terms of minerals, anions, TDS, alkalinity, hardness and pH.
We analyzed contents of cations and anions for the domestic bottled drinking water. Results showed that total cation content was 45.81 mg/L and contained 40% of Ca. The content of cations were decreased in the order of Ca>Si>Na>Mg>K. Total anion content was 12.20 mg/L and contained 90% of ${SO_4}^{2-}$ and $Cl^-$. $F^-$ and $NO_{3-}N$ were a little contained. While Si content was reduced 2.3~75.7%(mean value:38.5%) after freezing, Ca content was reduced 45.2% after boiling. It showed that water containing higher Ca content was significantly decreased after boiling. Precipitates formed by freezing and boiling is composed of minerals such as Si and Ca. Compared to minerals from food intake, concentrations of minerals from water intake are expected to be less influenced. It is recommended Bottled Water that contains more than 20 mg/L of Ca(exceeding water-quality standard for turbidity) is safe to drink without thawing and boiling.
Objectives: The market for bottled water is increasing steadily in South Korea. Bottled water contains several naturally occuring minerals, such as calcium, magnesium, sodium, and fluoride. Fluoride is proven to be effective in preventing dental caries. In South Korea, the maximum permissible concentration of fluoride is 2 ppm for bottled water and 1.5 ppm for tap water. The aim of this study was to investigate the fluoride content of different commercially available brands of bottled water in South Korea, and compare the measured fluoride concentration to the concentration written on the label of each brand of bottled water. Methods: Twenty-seven of the 59 different brands of bottled water produced in South Korea were investigated in this study. Three bottles of each brand were purchased from supermarkets, marts, and convenience stores in each region of Korea in August 2016. For each bottled water brand, the fluoride content was measured three times using a fluoride-ion selective electrode (Orion ionplus Fluoride Electrode 9609, Orion Research, USA). The calibration curve was generated using 0.2 and 2 ppm standard solutions, and confirmed using a 1 ppm standard solution. Results: The mean fluoride content of the 27 brands of bottled water was $0.374{\pm}0.332mg/L$ (range=0.040 to 1.172 mg/L). The fluoride content was labeled by the manufacturer, on each of the tested brands of bottled water. In eight brands, the labeled fluoride content differed from the experimental data. The minimum to maximum fluoride content measured from 10 brands showed a variation of 0.3 mg/L or more when compared to the labeled fluoride content. Conclusions: This study investigated the fluoride content of various brands of bottled water produced in South Korea and compared the measured fluoride levels with fluoride information on the bottle labels. To ensure that consumers are suitably informed regarding their exposure to fluoride, correct labelling of fluoride content in bottled water is important.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.